316 research outputs found

    Dynamical Exchange Effects in a Two-Dimensional Many-Polaron Gas

    Full text link
    We calculate the influence of dynamical exchange effects on the response properties and the static properties of a two-dimensional many-polaron gas. These effects are not manifested in the random-phase approximation which is widely used in the analysis of the many-polaron system. Here they are taken into account by using a dielectric function derived in the time-dependent Hartree-Fock formalism. At weak electron-phonon coupling, we find that dynamical exchange effects lead to substantial corrections to the random-phase approximation results for the ground state energy, the effective mass, and the optical conductivity of the polaron system. Furthermore, we show that the reduction of the spectral weight of the optical absorption spectrum at frequencies above the longitudinal optical phonon frequency, due to many-body effects, is overestimated by the random-phase approximation.Comment: 9 pages, 7 figure

    On the validity of the Franck-Condon principle in the optical spectroscopy: optical conductivity of the Fr\"{o}hlich polaron

    Get PDF
    The optical absorption of the Fr\"{o}hlich polaron model is obtained by an approximation-free Diagrammatic Monte Carlo method and compared with two new approximate approaches that treat lattice relaxation effects in different ways. We show that: i) a strong coupling expansion, based on the the Franck-Condon principle, well describes the optical conductivity for large coupling strengths (α>10\alpha >10); ii) a Memory Function Formalism with phonon broadened levels reproduces the optical response for weak coupling strengths (α<6\alpha <6) taking the dynamic lattice relaxation into account. In the coupling regime 6<α<106<\alpha<10 the optical conductivity is a rapidly changing superposition of both Franck-Condon and dynamic contributions.Comment: accepted for publication in PR

    Variational Approach to Hydrogen Atom in Uniform Magnetic Field of Arbitrary Strength

    Get PDF
    Extending the Feynman-Kleinert variational approach, we calculate the temperature-dependent effective classical potential governing the quantum statistics of a hydrogen atom in a uniform magnetic at all temperatures. The zero-temperature limit yields the binding energy of the electron which is quite accurate for all magnetic field strengths and exhibits, in particular, the correct logarithmic growth at large fields.Comment: Author Information under this http://www.physik.fu-berlin.de/~kleinert/institution.html Latest update of paper also at this http://www.physik.fu-berlin.de/~kleinert/30

    Optical Absorption of an Interacting Many-Polaron Gas

    Full text link
    The optical absorption of a many (continuum) polaron gas is derived in the framework of a variational approach at zero temperature and weak or intermediate electron-phonon coupling strength. We derive a compact formula for the optical conductivity of the many-polaron system taking into account many-body effects in the electron or hole system. Within the method presented here, these effects are contained completely in the dynamical structure factor of the electron or hole system. This allows to build on well-established studies of the interacting electron gas. Based on this approach a novel feature in the absorption spectrum of the many-polaron gas, related to the emission of a plasmon together with a phonon, is identified. As an application and illustration of the technique, we compare the theoretical many-polaron optical absorption spectrum as derived in the present work with the `d-band' absorption feature in Nd2_{2}CuO2_{2}. Similarities are shown between the theoretically and the experimentally derived first frequency moment of the optical absorption of a family of differently doped Nd2x_{2-x}Cex_{x}CuO4y_{4-y} materials.Comment: 24 pages, 5 figures; revised and expanded versio

    Frohlich mass in GaAs-based structures

    Full text link
    The Frohlich interaction is one of the main electron-phonon intrinsic interactions in polar materials originating from the coupling of one itinerant electron with the macroscopic electric field generated by any longitudinal optical (LO) phonon. Infra-red magneto-absorption measurements of doped GaAs quantum wells structures have been carried out in order to test the concept of Frohlich interaction and polaron mass in such systems. These new experimental results lead to question the validity of this concept in a real system.Comment: 4 pages, 3 figure

    Influence of the Characteristics of the STM-tip on the Electroluminescence Spectra

    Full text link
    We analyze the influence of the characteristics of the STM-tip (applied voltage, tip radius) on the electroluminescence spectra from an STM-tip-induced quantum dot taking into account the many-body effects. We find that positions of electroluminescence peaks, attributed to the electron-hole recombination in the quantum dot, are very sensitive to the shape and size of the confinement potential as determined by the tip radius and the applied voltage. A critical value of the tip radius is found, at which the luminescence peak positions as a function of the tip radius manifest a transition from decreasing behavior for smaller radii to increasing behavior for larger radii. We find that this critical value of the tip radius is related to the confinement in the lateral and normal direction.Comment: 15 pages, 5 figure

    Momentum distribution of confined bosons: temperature dependence

    Full text link
    The momentum distribution function of a parabolically confined gas of bosons with harmonic interparticle interactions is derived. In the Bose-Einstein condensation region, this momentum distribution substantially deviates from a Maxwell-Boltzmann distribution. It is argued that the determination of the temperature of the boson gas from the Bose-Einstein momentum distribution function is more appropriate than the currently used fitting to the high momentum tail of the Maxwell-Boltzmann distribution.Comment: 5 REVTEX pages + 2 postscript figures. Accepted in Phys. Rev.

    Quantum Simulations of Extended Hubbard Models with Dipolar Crystals

    Full text link
    In this paper we study the realization of lattice models in mixtures of atomic and dipolar molecular quantum gases. We consider a situation where polar molecules form a self-assembled dipolar lattice, in which atoms or molecules of a second species can move and scatter. We describe the system dynamics in a master equation approach in the Brownian motion limit of slow particles and fast phonons, which we find appropriate for our system. In a wide regime of parameters, the reduced dynamics of the particles leads to physical realizations of extended Hubbard models with tuneable long-range interactions mediated by crystal phonons. This extends the notion of quantum simulation of strongly correlated systems with cold atoms and molecules to include phonon-dynamics, where all coupling parameters can be controlled by external fields.Comment: 44 pages, 14 figure

    Semiquantitative interpretation of anticardiolipin and antiβ2glycoprotein I antibodies measured with various analytical platforms: communication from the ISTH SSC subcommittee on Lupus Anticoagulant/Antiphospholipid antibodies

    Get PDF
    Background Antiβ2glycoprotein I (aβ2GPI) and anticardiolipin (aCL) IgG/IgM show differences in positive/negative agreement and titers between solid phase platforms. Method specific semiquantitative categorization of titers could improve and harmonize the interpretation across platforms. Aim To evaluate the traditionally 40/80 units thresholds used for aCL and aβ2GPI for categorization into moderate/high positivity with different analytical systems, and to compare with alternative thresholds. Material and methods aCL and aβ2GPI thresholds were calculated for two automated systems (chemiluminescent immunoassay (CLIA) and multiplex flow immunoassay (MFI)) by ROC-curve analysis on 1108 patient samples, including patients with and without APS, and confirmed on a second population (n=279). Alternatively, regression analysis on diluted standard material was applied to identify thresholds. Thresholds were compared to 40/80 threshold measured by an enzyme linked immunosorbent assay (ELISA). Additionally, likelihood ratios (LR) were calculated. Results Threshold levels of 40/80 units show poor agreement between ELISA and automated platforms for classification into low/moderate/high positivity, especially for aCL/aβ2GPI IgG. Agreement for semiquantitative interpretation of aPL IgG between ELISA and CLIA/MFI improves with alternative thresholds. LR for aPL IgG increase for thrombotic and obstetric APS based on 40/80 thresholds for ELISA and adapted thresholds for the other systems, but not for IgM. Conclusion Use of 40/80 units as medium/high thresholds is acceptable for aCL/aβ2GPI IgG ELISA, but not for CLIA and MFI. Alternative semiquantitative thresholds for non-ELISA platforms can be determined by a clinical approach or by using monoclonal antibodies. Semiquantitative reporting of aPL IgM has less impact on increasing probability for APS

    International multicenter, multiplatform study to validate Taipan snake venom time as a lupus anticoagulant screening test with ecarin time as the confirmatory test: communication from the ISTH SSC subcommittee on Lupus Anticoagulant/Antiphospholipid antibodies

    Get PDF
    Background Lupus anticoagulant (LA) assays are compromised in anticoagulated patients, and existing strategies to overcome the interferences have limitations. The prothrombin-activating Taipan snake venom time (TSVT) screening test and ecarin time (ET) confirmatory test are innately insensitive to vitamin K antagonists (VKA) and direct factor Xa inhibitors (DFXaI). Objectives Validate standardised TSVT/ET reagents for LA detection, in a multi-centre, multi-platform study. Patients/Methods Six centres from four countries analysed samples with TSVT/ET from 81 non-anticoagulated patients with LA, patients with established antiphospholipid syndrome (APS) and proven persistent LA who were either not anticoagulated (n=120) or were anticoagulated with VKAs (n=180) or DFXaIs (n=71). Additionally, 339 non-anticoagulated LA-negative patients, and 575 anticoagulated non-APS patients (172 VKA, 403 DFXaI) were tested. Anticoagulant spiking experiments were performed and 112 samples containing potential interferences (i.e. direct thrombin inhibitors) were tested. Results were evaluated against locally derived cut-offs. Imprecision was evaluated. Results Cut-offs were remarkably similar despite use of different analysers and donor populations. Cut-offs for TSVT ratio, ET ratio, percent correction and normalised TSVT ratio/ET ratio ranged between 1.08-1.10, 1.09-1.12, 9.3%-14.8% and 1.10-1.15 respectively. Coefficients of variation for TSVT and ET ratios were ≤5.0%. TSVT/ET exhibited sensitivity, specificity, negative and positive predictive values of 78.2%/95.0%/86.3%/91.5% respectively with established APS as the LA-positive population, and 86.9%/95.0%/76.8%/97.4% respectively with triple-positive APS. Interference was seen with direct thrombin inhibitors, unfractionated heparin and low molecular weight heparins, but not VKAs or DFXaIs. Conclusions TSVT/ET are validated for LA detection in non-anticoagulated patients and those on VKAs or DFXaIs
    corecore