165 research outputs found
High Data Density Temperature Measurement for Quasi Steady-State Flows
A new optical instrument, the liquid crystal point diffraction interferometer (LCPDI), is used to measure the temperature distribution across a heated chamber filled with silicone oil. Data taken using the LCPDI are compared to equivalent measurements made with a traversing thermo-couple and the two data sets show excellent agreement. This instrument maintains the compact, robust design of Linniks point diffraction interferometer and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wave-fronts with very high data density and with automated data reduction
Full-field 3D shape measurement of discontinuous specular objects by direct phase measuring deflectometry
With the advent of intelligent manufacturing, phase measuring deflectometry (PMD) has been widely studied for the measurement of the three-dimensional (3D) shape of specular objects. However, existing PMDs cannot measure objects having discontinuous specular surfaces. This paper presents a new direct PMD (DPMD) method that measures the full-field 3D shape of complicated specular objects. A mathematical model is derived to directly relate an absolute phase map to depth data, instead of the gradient. Two relevant parameters are calibrated using a machine vision-based method. On the basis of the derived model, a full-field 3D measuring system was developed. The accuracy of the system was evaluated using a mirror with known positions along an accurate translating stage. The 3D shape of a monolithic multi-mirror array having multiple specular surfaces was measured. Experimental results show that the proposed DPMD method can obtain the full-field 3D shape of specular objects having isolated and/or discontinuous surfaces accurately and effectively
Doppelheterodyn-Interferometrie fĂĽr hochgenaue Vermessung im Nahbereich
In diesem Aufsatz wurde ein Meßsystem vorgestellt, welches sich aus der Kombination der Zweiwellenlängen-Interferometrie mit dem intensitätsunabhängigen Heterodyn-Verfahren zusammensetzt. Die resultierende Doppelheterodyn-Interferometrie vereinigt die Vorteile der beiden Verfahren. Ein großer Eindeutigkeitsbereich entsprechend der effektiven Wellenlänge A entsteht, darüberhinaus sind optisch rauhe Oberflächen als Meßobjekte zulässig; reduzierte Empfindlichkeit gegenüber Vibrationen und Umwelteinflüssen, hohe Auflösung infolge elektronischer Phasenbestimmung sowie hochgenaue Abstandsmessung in Echtzeit sind weitere Vorteile. Das Doppelheterodyn-Interferometer wird in Zukunft zu einem effektiven und dynamischen Meßinstrument zur hochgenauen Entfernungsmessung im Mikrometerbereich bis hin zu Meßdistanzen von 100 m entwickelt werden, für das sich schon jetzt zahlreiche Einsatzmöglichkeiten abzeichnen
Deqi sensations without cutaneous sensory input: results of an RCT
<p>Abstract</p> <p>Background</p> <p>Deqi is defined in relation to acupuncture needling as a sensory perception of varying character. In a recently published sham laser validation study, we found that subjects in the verum and the sham laser group experienced deqi sensations. Therefore, we aim to further analyze whether the perceptions reported in the two study arms were distinguishable and whether expectancy effects exhibited considerable impact on our results.</p> <p>Methods</p> <p>A detailed re-analysis focusing on deqi sensations was performed from data collected in a previously published placebo-controlled, double-blind, clinical cross-over trial for a sham laser evaluation. Thirty-four healthy volunteers (28 ± 10.7 years; 16 women, 18 men) received two laser acupuncture treatments at three acupuncture points LI4 (hégu), LU7 (liéque), and LR3 (táichong); once by verum laser and once using a sham device containing an inactive laser in randomized order. Outcome measures were frequency, intensity (evaluated by visual analogue scale; VAS), and quality of the subjects' sensations perceived during treatments (assessed with the "acupuncture sensation scale").</p> <p>Results</p> <p>Both, verum and the sham laser acupuncture result in similar deqi sensations with regard to frequency (p-value = 0.67), intensity (p-value = 0.71) and quality (p-values between 0.15 - 0.98). In both groups the most frequently used adjectives to describe these perceptions were "spreading", "radiating", "tingling", "tugging", "pulsing", "warm", "dull", and "electric". Sensations reported were consistent with the perception of deqi as previously defined in literature. Subjects' conviction regarding the effectiveness of laser acupuncture or the history of having received acupuncture treatments before did not correlate with the frequency or intensity of sensations reported.</p> <p>Conclusions</p> <p>Since deqi sensations, described as sensory perceptions, were elicited without any cutaneous sensory input, we assume that they are a product of non-specific effects from the overall treatment procedure. Expectancy-effects due to previous acupuncture experience and belief in laser acupuncture do not seem to play a major role in elicitation of deqi sensations. Our results give hints that deqi might be a central phenomenon of awareness and consciousness, and that its relevance should be taken into account, even in clinical trials. However, further research is required to understand mechanisms underlying deqi.</p
Testing of aspheric surfaces with computer generated holograms
Aspherical surfaces are becoming more important and can even be mass producted. There is a need for flexible test methods of high accuracy. The paper describes the combination of a computer generated holograms with a partially compensating lens as a powerful tool. An example for testing a steep aspheric surface will be given
From little things, big things grow: trends and fads in 110 years of Australian ornithology
Publishing histories can reveal changes in ornithological effort, focus or direction through time. This study presents a bibliometric content analysis of Emu (1901–2011) which revealed 115 trends (long-term changes in publication over time) and 18 fads (temporary increases in publication activity) from the classification of 9,039 articles using 128 codes organised into eight categories (author gender, author affiliation, article type, subject, main focus, main method, geographical scale and geographical location). Across 110 years, private authorship declined, while publications involving universities and multiple institutions increased; from 1960, female authorship increased. Over time, question-driven studies and incidental observations increased and decreased in frequency, respectively. Single species and ‘taxonomic group’ subjects increased while studies of birds at specific places decreased. The focus of articles shifted from species distribution and activities of the host organisation to breeding, foraging and other biological/ecological topics. Site- and Australian-continental-scales slightly decreased over time; non-Australian studies increased from the 1970s. A wide variety of fads occurred (e.g. articles on bird distribution, 1942–1951, and using museum specimens, 1906–1913) though the occurrence of fads decreased over time. Changes over time are correlated with technological, theoretical, social and institutional changes, and suggest ornithological priorities, like those of other scientific disciplines, are temporally labil
Phase-error restraint with the empirical mode decomposition method in phase measurement profilometry
- …