1,959 research outputs found

    The intrinsic normal cone

    Full text link
    We suggest a construction of virtual fundamental classes of certain types of moduli spaces.Comment: LaTeX, Postscript file available at http://www.math.ubc.ca/people/faculty/behrend/inc.p

    Contralateral inhibition of click- and chirp-evoked human compound action potentials

    Get PDF
    Cochlear outer hair cells (OHC) receive direct efferent feedback from the caudal auditory brainstem via the medial olivocochlear (MOC) bundle. This circuit provides the neural substrate for the MOC reflex, which inhibits cochlear amplifier gain and is believed to play a role in listening in noise and protection from acoustic overexposure. The human MOC reflex has been studied extensively using otoacoustic emissions (OAE) paradigms; however, these measurements are insensitive to subsequent “downstream” efferent effects on the neural ensembles that mediate hearing. In this experiment, click- and chirp-evoked auditory nerve compound action potential (CAP) amplitudes were measured electrocochleographically from the human eardrum without and with MOC reflex activation elicited by contralateral broadband noise. We hypothesized that the chirp would be a more optimal stimulus for measuring neural MOC effects because it synchronizes excitation along the entire length of the basilar membrane and thus evokes a more robust CAP than a click at low to moderate stimulus levels. Chirps produced larger CAPs than clicks at all stimulus intensities (50–80 dB ppeSPL). MOC reflex inhibition of CAPs was larger for chirps than clicks at low stimulus levels when quantified both in terms of amplitude reduction and effective attenuation. Effective attenuation was larger for chirp- and click-evoked CAPs than for click-evoked OAEs measured from the same subjects. Our results suggest that the chirp is an optimal stimulus for evoking CAPs at low stimulus intensities and for assessing MOC reflex effects on the auditory nerve. Further, our work supports previous findings that MOC reflex effects at the level of the auditory nerve are underestimated by measures of OAE inhibition

    New Florida Apportionment of Estate Taxes

    Get PDF

    Using monoclonal antibodies to prevent mucosal transmission of epidemic infectious diseases.

    Get PDF
    Passive immunization with antibodies has been shown to prevent a wide variety of diseases. Recent advances in monoclonal antibody technology are enabling the development of new methods for passive immunization of mucosal surfaces. Human monoclonal antibodies, produced rapidly, inexpensively, and in large quantities, may help prevent respiratory, diarrheal, and sexually transmitted diseases on a public health scale

    Determination of buprenorphine, norbuprenorphine, naloxone, and their glucuronides in urine by liquid chromatography–tandem mass spectrometry

    Get PDF
    Publisher Copyright: © 2021 The Authors. Drug Testing and Analysis published by John Wiley & Sons Ltd.A liquid chromatography–tandem mass spectrometry method for the simultaneous quantification of buprenorphine (BUP), norbuprenorphine (NBUP), naloxone (NAL), and their glucuronide conjugates BUP-G, NBUP-G, and NAL-G in urine samples was developed. The method, omitting a hydrolysis step, involved non-polar solid-phase extraction, liquid chromatography on a C18 column, electrospray positive ionization, and mass analysis by multiple reaction monitoring. Quantification was based on the corresponding deuterium-labelled internal standards for each of the six analytes. The limit of quantification was 0.5 μg/L for BUP and NAL, 1 μg/L for NAL-G, and 3 μg/L for NBUP, BUP-G, and NBUP-G. Using the developed method, 72 urine samples from buprenorphine-dependent patients were analysed to cover the concentration ranges encountered in a clinical setting. The median (maximum) concentration was 4.2 μg/L (102 μg/L) for BUP, 74.7 μg/L (580 μg/L) for NBUP, 0.9 μg/L (85.5 μg/L) for NAL, 159.5 μg/L (1370 μg/L) for BUP-G, 307.5 μg/L (1970 μg/L) for NBUP-G, and 79.6 μg/L (2310 μg/L) for NAL-G.Peer reviewe

    Mucoadhesive Nanoparticles May Disrupt the Protective Human Mucus Barrier by Altering Its Microstructure

    Get PDF
    Mucus secretions typically protect exposed surfaces of the eyes and respiratory, gastrointestinal and female reproductive tracts from foreign entities, including pathogens and environmental ultrafine particles. We hypothesized that excess exposure to some foreign particles, however, may cause disruption of the mucus barrier. Many synthetic nanoparticles are likely to be mucoadhesive due to hydrophobic, electrostatic or hydrogen bonding interactions. We therefore sought to determine whether mucoadhesive particles (MAP) could alter the mucus microstructure, thereby allowing other foreign particles to more easily penetrate mucus. We engineered muco-inert probe particles 1 µm in diameter, whose diffusion in mucus is limited only by steric obstruction from the mucus mesh, and used them to measure possible MAP-induced changes to the microstructure of fresh human cervicovaginal mucus. We found that a 0.24% w/v concentration of 200 nm MAP in mucus induced a ∼10-fold increase in the average effective diffusivity of the probe particles, and a 2- to 3-fold increase in the fraction capable of penetrating physiologically thick mucus layers. The same concentration of muco-inert particles, and a low concentration (0.0006% w/v) of MAP, had no detectable effect on probe particle penetration rates. Using an obstruction-scaling model, we determined that the higher MAP dose increased the average mesh spacing (“pore” size) of mucus from 380 nm to 470 nm. The bulk viscoelasticity of mucus was unaffected by MAP exposure, suggesting MAP may not directly impair mucus clearance or its function as a lubricant, both of which depend critically on the bulk rheological properties of mucus. Our findings suggest mucoadhesive nanoparticles can substantially alter the microstructure of mucus, highlighting the potential of mucoadhesive environmental or engineered nanoparticles to disrupt mucus barriers and cause greater exposure to foreign particles, including pathogens and other potentially toxic nanomaterials

    Performance of Self-Report to Establish Cancer Diagnoses in Disaster Responders and Survivors, World Trade Center Health Registry, New York, 2001–2007

    Get PDF
    Objective. Large-scale disasters may disrupt health surveillance systems, depriving health officials and researchers of timely and accurate information needed to assess disaster-related health effects and leading to use of less reliable self-reports of health outcomes. In particular, ascertainment of cancer in a population is ordinarily obtained through linkage of self-reported data with regional cancer registries, but exclusive reliance on these sources following a disaster may result in lengthy delays or loss of critical data. To assess the impact of such reliance, we validated self-reported cancer in a cohort of 59,340 responders and survivors of the World Trade Center disaster against data from 11 state cancer registries (SCRs). Methods. We focused on residents of the 11 states with SCRs and on cancers diagnosed from September 11, 2001, to the date of their last survey participation. Medical records were also sought in a subset of 595 self-reported cancer patients who were not recorded in an SCR. Results. Overall sensitivity and specificity of self-reported cancer were 83.9% (95% confidence interval [CI] 81.9, 85.9) and 98.5% (95% CI 98.4, 98.6), respectively. Site-specific sensitivities were highest for pancreatic (90.9%) and testicular (82.4%) cancers and multiple myeloma (84.6%). Compared with enrollees with true-positive reports, enrollees with false-negative reports were more likely to be non-Hispanic black (adjusted odds ratio [aOR] 5 1.8, 95% CI 1.2, 2.9) or Asian (aOR52.2, 95% CI 1.2, 4.1). Among the 595 cases not recorded in an SCR, 13 of 62 (21%) cases confirmed through medical records were reportable to SCRs. Conclusion. Self-report of cancer had relatively high sensitivity among adults exposed to the World Trade Center disaster, suggesting that self-reports of other disaster-related conditions less amenable to external validation may also be reasonably valid

    Coherent Integration of 0.5 GHz Spectral Holograms at 1536 Nm Using Dynamic Biphase Codes

    Get PDF
    Spectral hole-burning-based optical processing devices are proposed for coherent integration of multiple high-bandwidth interference patterns in a spectral hole-burning medium. In this implementation, 0.5 GHz spectral holographic gratings are dynamically accumulated in Er3+:Y2SiO5 style= position: relative; tabindex= 0 id= MathJax-Element-1-Frame \u3eEr3+:Y2SiO5 at 4.2 K using a 1536 nm laser frequency stabilized to a spectral hole, along with commercial off-the-shelf components. The processed data, representing time delays over 0.5–2.0 μs, were optically read out using a frequency-swept probe; this approach makes possible the use of low-bandwidth, large-dynamic-range detectors and digitizers and enables competitive processing for applications such as radar,lidar, and radio astronomy. Coherent integration dynamics and material advances are reported

    Time-resolved soft x-ray spectra from laser-produced Cu plasma

    Get PDF
    The volumetric heating of a thin copper target has been studied with time resolved x-ray spectroscopy. The copper target was heated from a plasma produced using the Lawrence Livermore National Laboratory's Compact Multipulse Terrawatt (COMET) laser. A variable spaced grating spectrometer coupled to an x-ray streak camera measured soft x-ray emission (800-1550 eV) from the back of the copper target to characterize the bulk heating of the target. Radiation hydrodynamic simulations were modeled in 2-dimensions using the HYDRA code. The target conditions calculated by HYDRA were post-processed with the atomic kinetics code CRETIN to generate synthetic emission spectra. A comparison between the experimental and simulated spectra indicates the presence of specific ionization states of copper and the corresponding electron temperatures and ion densities throughout the laser-heated copper target
    corecore