19 research outputs found

    Comparison of procedural efficacy and biophysical parameters between two competing cryoballoon technologies for pulmonary vein isolation: Insights from an initial multicenter experience

    Get PDF
    Introduction: Recently a novel cryoballoon system (POLARx, Boston Scientific) became available for the treatment of atrial fibrillation. This cryoballoon is comparable with Arctic Front Advance Pro (AFA-Pro, Medtronic), however, it maintains a constant balloon pressure. We compared the procedural efficacy and biophysical characteristics of both systems. Methods: One hundred and ten consecutive patients who underwent first-time cryoballoon ablation (POLARx: n = 57; AFA-Pro: n = 53) were included in this prospective cohort study. Results: Acute isolation was achieved in 99.8% of all pulmonary veins (POLARx: 99.5% vs. AFA-Pro: 100%, p = 1.00). Total procedure time (81 vs. 67 min, p <.001) and balloon in body time (51 vs. 35 min, p <.001) were longer with POLARx. After a learning curve, these times were similar. Cryoablation with POLARx was associated with shorter time to balloon temperature −30°C (27 vs. 31 s, p <.001) and −40°C (32 vs. 54 s, p <.001), lower balloon nadir temperature (−55°C vs. −47°C, p <.001), and longer thawing time till 0°C (16 vs. 9 s, p <.001). There were no differences in time-to-isolation (TTI; POLARx: 45 s vs. AFA-Pro 43 s, p =.441), however, POLARx was associated with a lower balloon temperature at TTI (−46°C vs. −37°C, p <.001). Factors associated with acute isolation differed between groups. The incidence of phrenic nerve palsy was comparable (POLARx: 3.5% vs. AFA-Pro: 3.7%). Conclusion: The novel cryoballoon is comparable to AFA-Pro and requires only a short learning curve to get used to the slightly different handling. It was associated with faster cooling rates and lower

    Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF).

    Get PDF
    AIMS Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications. METHODS AND RESULTS This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each). CONCLUSION In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement

    Serum Catestatin Concentrations Are Increased in Patients with Atrial Fibrillation

    No full text
    The autonomic nervous system is crucial in initiating and maintaining atrial fibrillation (AF). Catestatin is a multipurpose peptide that regulates cardiovascular systems and reduces harmful, excessive activity of the sympathetic nervous system by blocking the release of catecholamines. We aimed to determine whether serum catestatin concentrations are associated with AF severity, duration indices, and various clinical and laboratory indicators in these individuals to better define the clinical value of catestatin in patients with AF. The present single center study enrolled 73 participants with AF and 72 healthy age-matched controls. Serum catestatin concentrations were markedly higher in AF patients than controls (14.11 (10.21–26.02) ng/mL vs. 10.93 (5.70–20.01) ng/mL, p = 0.013). Furthermore, patients with a more severe form of AF had significantly higher serum catestatin (17.56 (12.80–40.35) vs. 10.98 (8.38–20.91) ng/mL, p = 0.001). Patients with higher CHA2DS2-VASc scores (17.58 (11.89–37.87) vs. 13.02 (8.47–22.75) ng/mL, p = 0.034) and higher NT-proBNP levels (17.58 (IQR 13.91–34.62) vs. 13.23 (IQR 9.04–22.61), p = 0.036) had significantly higher serum catestatin concentrations. Finally, AF duration correlated negatively with serum catestatin levels (r = −0.348, p = 0.003). The results of the present study implicate the promising role of catestatin in the intricate pathophysiology of AF, which should be explored in future research

    COVID-19 pandemic: Impact on the cardiac implantable electronic devices’ implantation rates in Croatia

    No full text
    Introduction Coronavirus disease 2019 (COVID-19) pandemic has influenced health-care organization worldwide, including management of non-communicable diseases. The aim of this study was to determine the impact of COVID-19 pandemic on cardiac implantable electronic devices’ (CIEDs) implantation rates in Croatia. Methods A retrospective, observational, national study was conducted. The data on CIEDs’ implantation rates from 20 Croatian implantation centres, between January 2018 and June 2021, were extracted from the national Health Insurance Fund registry. Implantation rates before and after COVID-19 pandemic started, were compared. Results The overall numbers of CIED implantations in Croatia during COVID-19 pandemic were not different in comparison to 2 years pre-COVID-19 time (2618 vs. 2807, p = .081). The pacemaker implantation rates decreased significantly (by 45%) during April (122 vs. 223, p Conclusion To the authors best knowledge this is a first study including complete national data on CIED implantation rates and COVID-19 pandemic impact. A significant reduction in number of both pacemaker and ICD implants during specific months of the COVID-19 pandemic was determined. However, afterwards compensation in implants resulted in similar total number when the complete year was evaluated

    COVID-19 pandemic: Impact on the cardiac implantable electronic devices' implantation rates in Croatia.

    No full text
    IntroductionCoronavirus disease 2019 (COVID-19) pandemic has influenced health-care organization worldwide, including management of non-communicable diseases. The aim of this study was to determine the impact of COVID-19 pandemic on cardiac implantable electronic devices' (CIEDs) implantation rates in Croatia.MethodsA retrospective, observational, national study was conducted. The data on CIEDs' implantation rates from 20 Croatian implantation centres, between January 2018 and June 2021, were extracted from the national Health Insurance Fund registry. Implantation rates before and after COVID-19 pandemic started, were compared.ResultsThe overall numbers of CIED implantations in Croatia during COVID-19 pandemic were not different in comparison to 2 years pre-COVID-19 time (2618 vs. 2807, p = .081). The pacemaker implantation rates decreased significantly (by 45%) during April (122 vs. 223, p ConclusionTo the authors best knowledge this is a first study including complete national data on CIED implantation rates and COVID-19 pandemic impact. A significant reduction in number of both pacemaker and ICD implants during specific months of the COVID-19 pandemic was determined. However, afterwards compensation in implants resulted in similar total number when the complete year was evaluated

    Pacemaker implantations monthly.

    No full text
    IntroductionCoronavirus disease 2019 (COVID-19) pandemic has influenced health-care organization worldwide, including management of non-communicable diseases. The aim of this study was to determine the impact of COVID-19 pandemic on cardiac implantable electronic devices’ (CIEDs) implantation rates in Croatia.MethodsA retrospective, observational, national study was conducted. The data on CIEDs’ implantation rates from 20 Croatian implantation centres, between January 2018 and June 2021, were extracted from the national Health Insurance Fund registry. Implantation rates before and after COVID-19 pandemic started, were compared.ResultsThe overall numbers of CIED implantations in Croatia during COVID-19 pandemic were not different in comparison to 2 years pre-COVID-19 time (2618 vs. 2807, p = .081). The pacemaker implantation rates decreased significantly (by 45%) during April (122 vs. 223, p ConclusionTo the authors best knowledge this is a first study including complete national data on CIED implantation rates and COVID-19 pandemic impact. A significant reduction in number of both pacemaker and ICD implants during specific months of the COVID-19 pandemic was determined. However, afterwards compensation in implants resulted in similar total number when the complete year was evaluated.</div
    corecore