1,069 research outputs found

    Emergent localized states at the interface of a twofold PT\mathcal{PT}-symmetric lattice

    Full text link
    We consider the role of non-triviality resulting from a non-Hermitian Hamiltonian that conserves twofold PT-symmetry assembled by interconnections between a PT-symmetric lattice and its time reversal partner. Twofold PT-symmetry in the lattice produces additional surface exceptional points that play the role of new critical points, along with the bulk exceptional point. We show that there are two distinct regimes possessing symmetry-protected localized states, of which localization lengths are robust against external gain and loss. The states are demonstrated by numerical calculation of a quasi-1D ladder lattice and a 2D bilayered square lattice.Comment: 10 pages, 7 figure

    Quantum error correction beyond qubits

    Full text link
    Quantum computation and communication rely on the ability to manipulate quantum states robustly and with high fidelity. Thus, some form of error correction is needed to protect fragile quantum superposition states from corruption by so-called decoherence noise. Indeed, the discovery of quantum error correction (QEC) turned the field of quantum information from an academic curiosity into a developing technology. Here we present a continuous-variable experimental implementation of a QEC code, based upon entanglement among 9 optical beams. In principle, this 9-wavepacket adaptation of Shor's original 9-qubit scheme allows for full quantum error correction against an arbitrary single-beam (single-party) error.Comment: realization of a Gaussian error correction protocol suitable for non-Gaussian error correctio

    Interplay between spin-orbit coupling and van Hove singularity in the Hund's metallicity of Sr2_2RuO4_4

    Full text link
    We investigate the dynamical properties of Sr2_2RuO4_4 at zero and very low temperature using density functional theory plus dynamical mean-field theory with an exact diagonalization solver. By considering rotationally invariant local interaction, we examine how Hund's coupling and spin-orbit coupling affect the correlated nature of the system. In the absence of Hund's coupling, the system shows a Fermi liquid behavior over the entire range of temperatures we consider. We confirm that the Fermi liquid persists at zero temperature even with nonzero Hund's coupling; however, at sufficient temperatures Hund's coupling significantly reduces the Fermi liquid regime and the system evolves into a typical Hund's metal. At the bare electronic occupancy of Sr2_2RuO4_4 (t2g4t_{2g}^4), a stronger Hund's metallicity accompanies a larger long-time correlator. Remarkably, electron doping further destabilizes the Fermi liquid even though the long-time correlator and magnetic fluctuations decrease upon doping. This suppression of the Fermi liquid is driven by the van Hove singularity above the Fermi level in Sr2_2RuO4_4, combined with an enhanced Van Vleck susceptibility by spin-orbit coupling. Such findings point to the important role that electronic structure plays in the behavior of Hund's metals, in addition to magnetic fluctuations.Comment: 7 pages, 4 figure

    Endosonography-Guided Pancreatic Duct Drainage for Chronic Pancreatitis: A Case Report and Review

    Get PDF
    A 50-year-old man was admitted to our department, complaining of epigastric pain and high fever. CT revealed a pseudocyst at the pancreatic head with upstream dilatation of the pancreatic duct (PD) and fluid collection surrounding the pancreas. Endosonography-guided PD drainage (ESPD) was performed because of unsuccessful ERCP. With a curved linear array echoendoscope, a 7.2 F catheter was placed in the PD. Laboratory data showed improvement in a few days and revealed disappearance of the fluid collection. Ten days after ESPD, a 7 F stent was placed in the PD via the puncture tract across the papilla of Vater followed by transpapillary replacement with a 10 F stent. CT showed a reduction in diameter of the PD and disappearance of the pseudocyst. ESPD is a feasible and useful procedure in selected patients with chronic pancreatitis showing stenosis of the main PD when transpapillary approach is impossible

    Iron and Nickel Line Diagnostics for the Galactic Center Diffuse Emission

    Get PDF
    We have observed the diffuse X-ray emission from the Galactic center (GC) using the X-ray Imaging Spectrometer (XIS) on Suzaku. The high-energy resolution and the low-background orbit provide excellent spectra of the GC diffuse X-rays (GCDX). The XIS found many emission lines in the GCDX near the energy of K-shell transitions of iron and nickel. The most pronounced features are FeI K alpha at 6.4 keV and K-shell absorption edge at 7.1 keV, which are from neutral and/or low ionization states of iron, and the K-shell lines at 6.7 keV and 6.9 keV from He-like (FeXXV K alpha) and hydrogenic (FeXXVI Ly alpha) ions of iron. In addition, K alpha lines from neutral or low ionization nickel (NiI K alpha) and He-like nickel (NiXXVII K alpha), and FeI K beta, FeXXV K beta, FeXXVI Ly beta, FeXXV K gamma and FeXXVI Ly gamma are detected for the first time. The line center energies and widths of FeXXV K alpha and FeXXVI Ly alpha favor a collisional excitation (CE) plasma for the origin of the GCDX. The electron temperature determined from the line flux ratio of FeXXV K alpha / FeXXV K beta is similar to the ionization temperature determined from that of FeXXV K alpha /FeXXVI Ly alpha. Thus it would appear that the GCDX plasma is close to ionization equilibrium. The 6.7 keV flux and temperature distribution to the galactic longitude is smooth and monotonic,in contrast to the integrated point source flux distribution. These facts support the hypothesis that the GCDX is truly diffuse emission rather than the integration of the outputs of a large number of unresolved point sources. In addition, our results demonstrate that the chemical composition of Fe in the interstellar gas near the GC is constrained to be about 3.5 times solar.Comment: 11 pages, 19 figures. Accepted for publication in PASJ Suzaku Special Issue (vol. 59 sp. 1

    Orthogonal antibody testing for COVID-19 among healthcare workers in a non-epidemic place and time: Japan's Iwate Prefecture, May 18-31, 2020

    Get PDF
    Of the 47 prefectures in Japan, Iwate had the fewest cases of coronavirus disease 2019 (COVID-19), with the first diagnosis officially confirmed on July 28, 2020. A baseline serological survey of COVID-19 antibodies is essential to accurately evaluate an epidemic outbreak. The primary purpose of this study was to determine pre-epidemic prevalence of COVID-19 antibodies among healthcare workers, using two laboratory-based quantitative tests. In addition, a point-of-care (POC) qualitative test, rapid, simple, and convenient for primary care clinics, was compared with the laboratory-based tests. All antibody tests were performed on serum from 1,000 healthcare workers (mean age, 40 ± 11 years) in Iwate Prefectural Central Hospital, May 29-31, 2020. A COVID-19 case was defined as showing positive results in both laboratory-based quantitative tests. None of 1,000 samples had positive results in both of the laboratory immunoassays. The POC test showed positive results in 33 of 1,000 samples (3.3%) (95% confidence interval:2.19-4.41), but no samples were simultaneously positive in both laboratory-based tests. In conclusion, COVID-19 cases were not serologically confirmed by a baseline control study of healthcare workers at our hospital in late May, 2020. Moreover, the POC qualitative test may offer no advantage in areas with very low prevalence of COVID-19, due to higher false-positive reactions compared with laboratory-based quantitative immunoassays

    Inter-annual variation in CH4 efflux and the associated processes with reference to delta-13C-, delta-D-CH4 at the Lowland of Indigirka River in Northeastern Siberia

    Get PDF
    第6回極域科学シンポジウム分野横断セッション:[IA] 急変する北極気候システム及びその全球的な影響の総合的解明―GRENE北極気候変動研究事業研究成果報告2015―11月19日(木) 国立極地研究所1階交流アトリウ
    corecore