6 research outputs found

    Evaluation of the acceptability of point of care diagnostic test for prenatal toxoplasmosis (translational research phase III)

    No full text
    Background: A new point of care test (POC) was developed that is promising as a tool to enhance impact of prenatal care programs for toxoplasmosis, however, no reports exist about its use or acceptability for healthcare personnel and mothers in Colombia. Methods: This was a translational research - phase III study of the acceptability of a new POC test (Toxoplasma ICT IgG-IgM, LDBio) for qualitative diagnosis of toxoplasmosis in 783 pregnant women and 30 health personnel in primary health care sites in the city of Armenia, Quindío (Colombia). Along with collection of the results of diagnostic POC and confirmatory test and demographic information, we evaluated acceptability through measure of the willingness, credibility, and satisfaction by using questionnaires with a Likert scale during routine prenatal care visits. Results: POC positivity was 46.5% among pregnant participants and was significantly related to socioeconomic factors, including education level (p = 0.00000000) and insurance status (p = 0.00000015). A total of 93–97% of healthcare personnel indicated agreement to positive statements regarding total satisfaction and total credibility of the LDBio test, but qualitative questions identified “Difficulty in the test procedure” as the most common response about barriers to apply the test. Greater than 90% of pregnant participants agree that POC test should be routine for all pregnant woman and permanently implemented. Conclusions: The test had near complete acceptability. In future studies it is necessary to examine the effect of non-differentiation between IgG and IgM isotypes

    Novel paradigm enables accurate monthly gestational screening to prevent congenital toxoplasmosis and more

    No full text
    International audienceBackground Congenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide. Objectives We asked whether high performance of an Immunochromatographic-test (ICT) could enable accurate, rapid diagnosis/treatment, establishing new, improved care-paradigms at point-of-care and clinical laboratory. Methods Data were obtained in 12 studies/analyses addressing: 1-feasibility/efficacy; 2-false-positives; 3-acceptability; 4-pink/black-line/all studies; 5-time/cost; 6-Quick-Information/Limit-of-detection; 7, 8-acute;-chronic; 9-epidemiology; 10-ADBio; 11,12-Commentary/Cases/Chronology. Findings ICT was compared with gold-standard or predicate-tests. Overall, ICT performance for 1093 blood/4967 sera was 99.2%/97.5% sensitive and 99.0%/99.7% specific. However, in clinical trial, FDA-cleared-predicate tests initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyon’s Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false-positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO REASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening. Conclusions/significance This novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories. Trial registration NCT04474132 , https://clinicaltrials.gov/study/NCT04474132 ClinicalTrials.go

    Novel paradigm enables accurate monthly gestational screening to prevent congenital toxoplasmosis and more.

    No full text
    BackgroundCongenital toxoplasmosis is a treatable, preventable disease, but untreated causes death, prematurity, loss of sight, cognition and motor function, and substantial costs worldwide.ObjectivesWe asked whether high performance of an Immunochromatographic-test (ICT) could enable accurate, rapid diagnosis/treatment, establishing new, improved care-paradigms at point-of-care and clinical laboratory.MethodsData were obtained in 12 studies/analyses addressing: 1-feasibility/efficacy; 2-false-positives; 3-acceptability; 4-pink/black-line/all studies; 5-time/cost; 6-Quick-Information/Limit-of-detection; 7, 8-acute;-chronic; 9-epidemiology; 10-ADBio; 11,12-Commentary/Cases/Chronology.FindingsICT was compared with gold-standard or predicate-tests. Overall, ICT performance for 1093 blood/4967 sera was 99.2%/97.5% sensitive and 99.0%/99.7% specific. However, in clinical trial, FDA-cleared-predicate tests initially caused practical, costly problems due to false-positive-IgM results. For 58 persons, 3/43 seronegative and 2/15 chronically infected persons had false positive IgM predicate tests. This caused substantial anxiety, concerns, and required costly, delayed confirmation in reference centers. Absence of false positive ICT results contributes to solutions: Lyon and Paris France and USA Reference laboratories frequently receive sera with erroneously positive local laboratory IgM results impeding patient care. Therefore, thirty-two such sera referred to Lyon's Reference laboratory were ICT-tested. We collated these with other earlier/ongoing results: 132 of 137 USA or French persons had false-positive local laboratory IgM results identified correctly as negative by ICT. Five false positive ICT results in Tunisia and Marseille, France, emphasize need to confirm positive ICT results with Sabin-Feldman-Dye-test or western blot. Separate studies demonstrated high performance in detecting acute infections, meeting FDA, CLIA, WHO REASSURED, CEMark criteria and patient and physician satisfaction with monthly-gestational-ICT-screening.Conclusions/significanceThis novel paradigm using ICT identifies likely false positives or raises suspicion that a result is truly positive, rapidly needing prompt follow up and treatment. Thus, ICT enables well-accepted gestational screening programs that facilitate rapid treatment saving lives, sight, cognition and motor function. This reduces anxiety, delays, work, and cost at point-of-care and clinical laboratories.Trial registrationNCT04474132, https://clinicaltrials.gov/study/NCT04474132 ClinicalTrials.gov

    L’entrée en scène

    No full text
    « La plupart des artistes de théâtre, et beaucoup de metteurs en scène en premier lieu, reconnaissent que l’entrée en scène, ses modalités, sa dramaturgie, est un acte décisif : il engage tout le spectacle à venir, il détermine sa réception, il éveille la sensibilité du spectateur, et conditionne donc son intelligence. » Jean-Loup Rivière, Entrée libr
    corecore