20 research outputs found

    Lung tumour growth kinetics in SPC-c-Raf-1-BB transgenic mice assessed by longitudinal in-vivo micro-CT quantification

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>SPC-c-Raf-1-BxB transgenic mice develop genetically induced disseminated lung adenocarcinoma allowing examination of carcinogenesis and evaluation of novel treatment strategies. We report on assessment of lung tumour growth kinetics using a semiautomated region growing segmentation algorithm.</p> <p>Methods</p> <p>156 non contrast-enhanced respiratory gated micro-CT of the lungs were obtained in 12 SPC-raf transgenic (n = 9) and normal (n = 3) mice at different time points. Region-growing segmentation of the aerated lung areas was obtained as an inverse surrogate for tumour burden. Time course of segmentation volumes was assessed to demonstrate the potential of the method for follow-up studies.</p> <p>Results</p> <p>Micro-CT allowed assessment of tumour growth kinetics and semiautomated region growing enabled quantitative analysis. Significant changes of the segmented lung volumes over time could be shown (<it>p </it>= 0.009). Significant group differences could be detected between transgenic and normal animals for time points 8 to 13 months (<it>p </it>= 0.043), when marked tumour progression occurred.</p> <p>Conclusion</p> <p>The presented region-growing segmentation algorithm allows in-vivo quantification of multifocal lung adenocarcinoma in SPC-raf transgenic mice. This enables the assessment of tumour load and progress for the study of carcinogenesis and the evaluation of novel treatment strategies.</p

    Experimental Evaluation of the Heat Sink Effect in Hepatic Microwave Ablation.

    No full text
    To demonstrate and quantify the heat sink effect in hepatic microwave ablation (MWA) in a standardized ex vivo model, and to analyze the influence of vessel distance and blood flow on lesion volume and shape.108 ex vivo MWA procedures were performed in freshly harvested pig livers. Antennas were inserted parallel to non-perfused and perfused (700,1400 ml/min) glass tubes (diameter 5mm) at different distances (10, 15, 20mm). Ablation zones (radius, area) were analyzed and compared (Kruskal-Wallis Test, Dunn's multiple comparison Test). Temperature changes adjacent to the tubes were measured throughout the ablation cycle.Maximum temperature decreased significantly with increasing flow and distance (p<0.05). Compared to non-perfused tubes, ablation zones were significantly deformed by perfused tubes within 15 mm distance to the antenna (p<0.05). At a flow rate of 700 ml/min ablation zone radius was reduced to 37.2% and 80.1% at 10 and 15 mm tube distance, respectively; ablation zone area was reduced to 50.5% and 89.7%, respectively.Significant changes of ablation zones were demonstrated in a pig liver model. Considerable heat sink effect was observed within a diameter of 15 mm around simulated vessels, dependent on flow rate. This has to be taken into account when ablating liver lesions close to vessels

    Demonstration of the heat sink effect in hepatic microwave ablation, depending on flow and distance to simulated hepatic vessels.

    No full text
    <p>Considerable changes in ablation zone morphology as reflected by minimum radius and lesion area can be observed in ablation procedures performed within 15mm of perfused vessels. Red cross = position of microwave antenna; blue circle = position of vessel; red arrow = minimal ablation zone radius; green arrow = maximum ablation zone radius; red dashed line = real ablation zone area; green line = idealized ablation zone area.</p

    Combined micro-PET/micro-CT imaging of lung tumours in SPC-raf and SPC-myc transgenic mice.

    Get PDF
    INTRODUCTION: SPC-raf and SPC-myc transgenic mice develop disseminated and circumscribed lung adenocarcinoma respectively, allowing for assessment of carcinogenesis and treatment strategies. The purpose of this study was to investigate the technical feasibility, the correlation of initial findings to histology and the administered radiation dose of combined micro-PET/micro-CT in these animal models. MATERIAL AND METHODS: 14 C57BL/6 mice (4 nontransgenic, 4 SPC-raf transgenic, 6 SPC-myc transgenic) were examined using micro-CT and (18)F-Fluoro-deoxyglucose micro-PET in-vivo. Micro-PET data was corrected for random events and scatter prior to reconstruction with a 3D-FORE/2D-OSEM iterative algorithm. Rigid micro-PET/micro-CT registration was performed. Tumour-to-non-tumour ratios were calculated for different lung regions and focal lesions. Diffuse tumour growth was quantified using a semiautomated micro-CT segmentation routine reported earlier. Regional histologic tumour load was assessed using a 4-point rating scale. Gamma radiation dose was determined using thermoluminescence dosimeters. RESULTS: Micro-CT allowed visualisation of diffuse and circumscribed tumours in SPC-raf and SPC-myc transgenic animals along with morphology, while micro-PET provided information on metabolism, but lacked morphologic detail. Mean tumour-to-non-tumour ratio was 2.47 for circumscribed lesions. No significant correlation could be shown between histological tumour load and tumour-to-nontumour ratio for diffuse tumours in SPC-raf transgenic animals. Calculation of the expected dose based on gamma dosimetry yielded approximately 140 mGy/micro-PET examination additional to approximately 200 mGy due to micro-CT. CONCLUSIONS: Combined micro-PET/micro-CT imaging allows for in-vivo assessment of lung tumours in SPC-raf and SPC-myc transgenic mice. The technique has potential for the evaluation of carcinogenesis and treatment strategies in circumscribed lung tumours

    Temperature profile in ex microwave ablation of porcine liver, dependent on vessel perfusion and vessel–applicator distance.

    No full text
    <p>Maximum temperature during the ablation cycle decreased significantly with increasing distance between vessel and microwave antenna as well as with increasing vessel flow (p<0.05).</p

    Demonstration of the heat sink effect in hepatic microwave ablation, depending on flow and distance to simulated hepatic vessels.

    No full text
    <p>Considerable changes in ablation zone morphology as reflected by minimum radius and lesion area can be observed in ablation procedures performed within 15mm of perfused vessels. Red cross = position of microwave antenna; blue circle = position of vessel; red arrow = minimal ablation zone radius; green arrow = maximum ablation zone radius; red dashed line = real ablation zone area; green line = idealized ablation zone area.</p
    corecore