17 research outputs found

    Impact of pacing mode and different echocardiographic parameters on cardiac output (PADIAC)

    Get PDF
    IntroductionThe extent of the hemodynamic benefit from AV-synchronous pacing in patients with sinus rhythm and AV block is not completely understood. Thus, we systematically investigated the association of an array of echocardiographic and epidemiological parameters with the change in cardiac output depending on the stimulation mode (AV-synchronous or AV-asynchronous pacing).MethodsPatients in sinus rhythm after previous dual chamber pacemaker implantation underwent a thorough basic echocardiographic assessment of diastolic and systolic left ventricular function, and atrial function (26 echo parameters, including novel speckle tracking strain measurements). Then, stroke volume was measured with AV-synchronous (DDD) and AV-asynchronous (VVI) pacing. Each patient represented their own control, and the sequence of stroke volume measurements was randomized.ResultsIn this prospective single-center study (NCT04068233, registration August 22nd 2019), we recruited 40 individuals. The stroke volume was higher in all patients when applying AV-synchronous DDD pacing [median increase 12.8 ml (16.9%), P < 0.001]. No echo parameter under investigation was associated with the extent of stroke volume increase in a linear regression model. Of all epidemiological variables, a history of acute myocardial infarction (AMI) was associated with an attenuated stroke volume gain in a univariate and a multivariate regression model that adjusted for confounders. A- and S-wave velocities were reduced in the AMI group.DiscussionIn our cohort of patients, each subject benefited from AV-synchronous DDD pacing. No single echo parameter could predict the amount of stroke volume increase. The beneficial effect of AV-synchronous pacing on stroke volume was attenuated after prior acute myocardial infarction.ClinicalTrials.gov identifier (NCT number): NCT04068233

    Artefacts in 1.5 Tesla and 3 Tesla cardiovascular magnetic resonance imaging in patients with leadless cardiac pacemakers

    No full text
    Abstract Background There are limited data on patients with leadless cardiac pacemakers (LCP) undergoing magnetic resonance imaging. The aim of this prospective, single-center, observational study was to evaluate artefacts on cardiovascular magnetic resonance (CMR) images in patients with LCP. Methods Fifteen patients with Micra™ LCP, implanted at least 6 weeks prior to CMR scan, were enrolled and underwent either 1.5 Tesla or 3 Tesla CMR imaging. Artefacts were categorized into grade 1 (excellent image quality), grade 2 (good), grade 3 (poor) and grade 4 (non-diagnostic) for each myocardial segment. One patient was excluded because of an incomplete CMR investigation due to claustrophobia. Results LCP caused an arc-shaped artefact (0.99 ± 0.16 cm2) at the right ventricular (RV) apex. Of 224 analyzed myocardial segments of the left ventricle (LV) 158 (70.5%) were affected by grade 1, 27 (12.1%) by grade 2, 17 (7.6%) by grade 3 and 22 (9.8%) by grade 4 artefacts. The artefact burden of grade 3 and 4 artefacts was significantly higher in the 3 Tesla group (3 Tesla vs 1.5 Tesla: 3.7 ± 1.6 vs 1.9 ± 1.4 myocardial segments per patient, p = 0.03). A high artefact burden was particularly observed in the mid anteroseptal, inferoseptal and apical septal myocardial segments of the LV and in the mid and apical segments of the RV. Quantification of LV function and assessment of valves were feasible in all patients. We did not observe any clinical or device-related adverse events. Conclusion CMR imaging in patients with LCP is feasible with excellent to good image quality in the majority of LV segments. The artefact burden is comparable small allowing an accurate evaluation of LV function, cardiac structures and valves. However, artefacts in the mid anteroseptal, inferoseptal and apical septal myocardial segments of the LV due to the LCP may impair or even exclude diagnostic evaluation of these segments. Artefacts on CMR images may be reduced by the use of 1.5 Tesla CMR scanners

    NT-pro-BNP as a Predictor for Recurrence of Atrial Fibrillation after Primary Cryoballoon Pulmonary Vein Isolation

    No full text
    NT-pro-BNP is produced in the cardiac atria and ventricles in response to increased wall stress. It may be a marker of both AF disease progression and co-morbidities that affect success after pulmonary vein isolation (PVI). This single-center retrospective study analyzed the association between pre-procedural NT-pro-BNP serum levels and the long-term outcome after a first-ever PVI in cryo-technique. Patients were followed by searching the hospital information system and conducting structured telephone interviews. Treatment failure was defined as any relapse of atrial fibrillation (AF) occurring 90 days after the index PVI at the earliest. Kaplan–Meier survival curves and Cox proportional hazards models were computed to assess the impact of NT-pro-BNP on AF recurrence. Following 374 patients over a median of 3.8 years (range: 0.25–9.4 years), baseline NT-pro-BNP was associated with the combined endpoint in univariate analysis (HR 1.04 per 100 pg/mL increase, 95% CI: 1.02–1.07, p < 0.001). Results were virtually unchanged in the multivariate model or if the data were log-transformed. Intraprocedural left atrial pressure correlated positively with log NT-pro-BNP. NT-pro-BNP was associated with AF relapse during a long-term follow-up after first-ever cryo-PVI in our cohort of patients with predominantly normal left ventricular function. This lab parameter is easy to obtain and has significant potential to guide treatment decisions

    Afatinib in NSCLC With HER2 Mutations: Results of the Prospective, Open-Label Phase II NICHE Trial of European Thoracic Oncology Platform (ETOP).

    No full text
    INTRODUCTION Mutations in erb-b2 receptor tyrosine kinase 2 (HER2) oncogene are observed in approximately 3% of lung adenocarcinomas or mixed tumors with adenocarcinoma component. Activity of various biologically distinct HER2 inhibitors, including the pan-HER inhibitor afatinib, has been reported in several retrospective trials or small series in advanced pretreated NSCLC with HER2 mutations. We report the first prospective evaluation of afatinib for the treatment of this molecularly defined entity. METHODS NICHE, a single-arm phase II trial using a two-stage Simon's design, explored the potential of afatinib to control disease in pretreated patients with advanced NSCLC harboring HER2 exon 20 mutations. A total of 13 patients entered the trial and were treated with afatinib 40 mg/day until tumor progression or lack of tolerability. RESULTS The first-stage stopping boundary was crossed when five of nine patients did not achieve disease control at 12 weeks. The accrual into the trial was stopped with total 13 patients enrolled, with 7 (53.8%) achieving disease control at 12 weeks. Except for 1 patient with early death, progression was documented for all patients, with median progression-free survival of 15.9 weeks (95% confidence interval: 6.0-35.4), and median overall survival of 56.0 weeks (95% confidence interval: 16.3- upper limit not estimable). The toxicity profile was in the expected range. CONCLUSIONS Afatinib did not show the expected potential for disease control in NSCLC. However, more than half of the patients in the full cohort achieved disease control at 12 weeks

    Economic assessment of traditional surgical intervention versus use of a new innovative radiofrequency based surgical system in device replacements

    No full text
    <div><p>Introduction</p><p>Intra-operative complications like mechanical damages to the leads, infections and hematomas during generator replacements of implantable pacemakers and defibrillators contribute to additional costs for hospitals. The aim of this study was to evaluate operation room use, costs and budget impact of generator replacements using either a traditional surgical intervention (TSI) with scissors, scalpel and electrocautery vs. a new radiofrequency energy based surgical system, called PEAK PlasmaBlade<sup>TM</sup> (PPB).</p><p>Materials and methods</p><p>We conducted a retrospective analysis of a population including 508 patients with TSI and 254 patients with PPB who underwent generator replacement at the Kepler University Hospital in Linz or the St. Josef Hospital in Braunau, Austria. The economic analysis included costs of resources used for intra-operative complications (lead damages) and of procedure time for TSI vs. PPB.</p><p>Results</p><p>Proportion of males, mean age and type of generator replaced were similar between the two groups. Lead damages occurred significantly more frequent with TSI than with PPB (5.3% and 0.4%; p< 0.001) and the procedure time was significantly longer with TSI than with PPB (47.9±24.9 and 34.1±18.1 minutes; p<0.001). Shorter procedure time and a lower rate of lead damages with PPB resulted in per patient cost savings of €81. Based on estimated 2,700 patients annually undergoing generator replacement in Austria, the use of PPB may translate into cost savings of €219,600 and 621 saved operating facility hours.</p><p>Conclusion</p><p>PPB has the potential to minimize the risk of lead damage with more efficient utilization of the operating room. Along with cost savings and improved quality of care, hospitals may use the saved operating room hours to increase the number of daily surgeries.</p></div
    corecore