4 research outputs found

    Quiescent-Interval Single-Shot Magnetic Resonance Angiography May Outperform Carbon-Dioxide Digital Subtraction Angiography in Chronic Lower Extremity Peripheral Arterial Disease

    No full text
    Nephroprotective imaging in peripheral arterial disease (PAD) is often crucial. We compared the diagnostic performance of non-contrast Quiescent-interval single-shot magnetic resonance angiography (QISS MRA) and carbon-dioxide digital subtraction angiography (CO2 DSA) in chronic lower extremity PAD patients. A 19-segment lower extremity arterial model was used to assess the degree of stenosis (none, <50%, 50–70%, >70%) and the image quality (5-point Likert scale: 1-non-diagnostic, 5-excellent image quality). Intra-class correlation coefficient (ICC) was calculated for inter-rater reliability. Diagnostic accuracy and interpretability were evaluated using CO2 DSA as a reference standard. 523 segments were evaluated in 28 patients (11 male, mean age: 71 ± 9 years). Median and interquartile range of subjective image quality parameters for QISS MRA were significantly better compared to CO2 DSA for all regions: (aortoiliac: 4 [4–5] vs. 3 [3–4]; femoropopliteal: 4 [4–5] vs. 4 [3–4]; tibioperoneal: 4 [3–5] vs. 3 [2–3]; all regions: 4 [4–5] vs. 3 [3–4], all p < 0.001). QISS MRA out-performed CO2 DSA regarding interpretability (98.3% vs. 86.0%, p < 0.001). Diagnostic accuracy parameters of QISS MRA for the detection of obstructive luminal stenosis (70%<) as compared to CO2 DSA were as follows: sensitivity 82.6%, specificity 96.9%, positive predictive value 89.1%, negative predictive value 94.8%. Regarding the degree of stenosis, interobserver variability for all regions was 0.97 for QISS MRA and 0.82 for CO2 DSA. QISS MRA proved to be superior to CO2 DSA regarding subjective image quality and interpretability for the imaging of chronic lower extremity PAD

    Incidence and predictors of stroke and silent cerebral embolism following very high-power short-duration atrial fibrillation ablation.

    No full text
    AimsCerebral thrombo-embolism is a dreaded complication of pulmonary vein isolation (PVI) for atrial fibrillation; its surrogate, silent cerebral embolism (SCE) can be detected by diffusion-weighted brain magnetic resonance imaging (bMRI). Initial investigations have raised a concern that very high-power, short-duration (vHPSD; 90 W/4 s) temperature-controlled PVI with the QDOT Micro catheter may be associated with a higher incidence of SCE compared with low-power long-duration ablation. We aimed to assess the incidence of procedural complications of vHPSD PVI with an emphasis on cerebral safety.Methods and resultsWe enrolled 328 consecutive patients undergoing their PVI procedure using vHPSD. A subgroup of 61 consecutive patients underwent diffusion-weighted bMRI within 24 h of the procedure, and incidence and predictors of SCE were studied. The mean procedure time and left atrial dwell time for the overall cohort were 69.6 ± 24.1 and 46.5 ± 21.5 min, respectively. First-pass isolation was achieved in 82%. No stroke or transient ischaemic attack occurred. Silent cerebral embolism was identified in 5 of 61 patients (8.2%). Silent cerebral embolism following procedures was significantly associated with lower baseline generator impedance (105.8 vs. 112.6 Ω, P ConclusionVery high-power, short-duration PVI is a safe technique with an excellent acute success rate. Silent cerebral embolism incidence in our cohort was below the previously reported range, with no clinically overt cerebral complications. Lower baseline generator impedance and loss of contact during ablation may contribute to a higher risk of SCEs

    Heart Rate-Dependent Degree of Motion Artifacts in Coronary CT Angiography Acquired by a Novel Purpose-Built Cardiac CT Scanner

    No full text
    Although reaching target heart rate (HR) before coronary CT angiography (CCTA) is still of importance, adequate HR control remains a challenge for many patients. Purpose-built cardiac scanners may provide optimal image quality at higher HRs by further improving temporal resolution. We aimed to compare the amount of motion artifacts on CCTA acquired using a dedicated cardiac CT (DCCT) compared to a conventional multidetector CT (MDCT) scanner. We compared 80 DCCT images to 80 MDCT scans matched by sex, age, HR, and coronary dominance. Image quality was graded on a per-patient, per-vessel and per-segment basis. Motion artifacts were assessed using Likert scores (1: non-diagnostic, 2: severe artifacts, 3: mild artifacts, 4: no artifacts). Patients were stratified into four groups according to HR (<60/min, 60–65/min, 66–70/min and >70/min). Overall, 2328 coronary segments were evaluated. DCCT demonstrated superior overall image quality compared to MDCT (3.7 ± 0.4 vs. 3.3 ± 0.7, p < 0.001). DCCT images yielded higher Likert scores in all HR ranges, which was statistically significant in the 60–65/min, 66–70/min and >70/min ranges (3.9 ± 0.2 vs. 3.7 ± 0.2, p = 0.008; 3.5 ± 0.5 vs. 3.1 ± 0.6, p = 0.048 and 3.5 ± 0.4 vs. 2.7 ± 0.7, p < 0.001, respectively). Using a dedicated cardiac scanner results in fewer motion artifacts, which may allow optimal image quality even in cases of high HRs
    corecore