55 research outputs found
Recommended from our members
Mechanical Design Analysis of MQXFB, the 7.2-m-Long Low-β Quadrupole for the High-Luminosity LHC Upgrade
As part of the High-Luminosity Large Hadron Collider (LHC) Project, a set of Nb Snquadrupoles are being developed, aiming to enhance the performance of the inner triplets. The new magnets, identified as MQXFA and MQXFB, will share the same cross section with two different lengths, 4.2 and 7.2 m, respectively. During the magnet development, three short models were tested, along with a number of mechanical models, demonstrating the capability of the magnet cross section to achieve the specified performances. The same performances are now required for the full-length magnets. To ensure this, the authors studied the impact of the magnet length on the capability of the structure to provide an adequate support to the coils. Finite element and simplified analytical models were used to evaluate the impact of the magnet length on the stresses in the magnet ends and coil elongation during powering. The models were calibrated using the results from the short model tests, and used to provide an indication on the required prestress and its foreseen impact on the magnet performance.
Superconducting ECR ion source: From 24-28 GHz SECRAL to 45 GHz fourth generation ECR.
The development of superconducting ECR source with higher magnetic fields and higher microwave frequency is the most straight forward path to achieve higher beam intensity and higher charge state performance. SECRAL, a superconducting third generation ECR ion source, is designed for 24-28 GHz microwave frequency operation with an innovative magnet configuration of sextupole coils located outside the three solenoids. SECRAL at 24 GHz has already produced a number of record beam intensities, such as 40Ar12+ 1.4 emA, 129Xe26+ 1.1 emA, 129Xe30+ 0.36 emA, and 209Bi31+ 0.68 emA. SECRAL-II, an upgraded version of SECRAL, was built successfully in less than 3 years and has recently been commissioned at full power of a 28 GHz gyrotron and three-frequency heating (28 + 45 + 18 GHz). New record beam intensities for highly charged ion production have been achieved, such as 620 eμA 40Ar16+, 15 eμA 40Ar18+, 146 eμA 86Kr28+, 0.5 eμA 86Kr33+, 53 eμA 129Xe38+, and 17 eμA 129Xe42+. Recent beam test results at SECRAL and SECRAL II have demonstrated that the production of more intense highly charged heavy ion beams needs higher microwave power and higher frequency, as the scaling law predicted. A 45 GHz superconducting ECR ion source FECR (a first fourth generation ECR ion source) is being built at IMP. FECR will be the world's first Nb3Sn superconducting-magnet-based ECR ion source with 6.5 T axial mirror field, 3.5 T sextupole field on the plasma chamber inner wall, and 20 kW at a 45 GHz microwave coupling system. This paper will focus on SECRAL performance studies at 24-28 GHz and technical design of 45 GHz FECR, which demonstrates a technical path for highly charged ion beam production from 24 to 28 GHz SECRAL to 45 GHz FECR
Insertion Magnets
Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC) : Preliminary
Design Report. The Large Hadron Collider (LHC) is one of the largest scientific
instruments ever built. Since opening up a new energy frontier for exploration
in 2010, it has gathered a global user community of about 7,000 scientists
working in fundamental particle physics and the physics of hadronic matter at
extreme temperature and density. To sustain and extend its discovery potential,
the LHC will need a major upgrade in the 2020s. This will increase its
luminosity (rate of collisions) by a factor of five beyond the original design
value and the integrated luminosity (total collisions created) by a factor ten.
The LHC is already a highly complex and exquisitely optimised machine so this
upgrade must be carefully conceived and will require about ten years to
implement. The new configuration, known as High Luminosity LHC (HL-LHC), will
rely on a number of key innovations that push accelerator technology beyond its
present limits. Among these are cutting-edge 11-12 tesla superconducting
magnets, compact superconducting cavities for beam rotation with ultra-precise
phase control, new technology and physical processes for beam collimation and
300 metre-long high-power superconducting links with negligible energy
dissipation. The present document describes the technologies and components
that will be used to realise the project and is intended to serve as the basis
for the detailed engineering design of HL-LHC.Comment: 19 pages, Chapter 3 in High-Luminosity Large Hadron Collider (HL-LHC)
: Preliminary Design Repor
Recommended from our members
Mechanical Performance of Short Models for MQXF, the Nb3Sn Low-β Quadrupole for the Hi-Lumi LHC
In the framework of the Hi-Lumi LHC Project, CERN and U.S. LARP are jointly developing MQXF, a 150-mm aperture high-field Nb3Sn quadrupole for the upgrade of the inner triplet of the low-beta interaction regions. The magnet is supported by a shell-based structure, providing the preload by means of bladder-key technology and differential thermal contraction of the various components. Two short models have been produced using the same cross section currently considered for the final magnet. The structures were preliminarily tested replacing the superconducting coils with blocks of aluminum. This procedure allows for model validation and calibration, and also to set performance goals for the real magnet. Strain gauges were used to monitor the behavior of the structure during assembly, cool down and also excitation in the case of the magnets. The various structures differ for the shell partitioning strategies adopted and for the presence of thick or thin laminations. This paper presents the results obtained and discusses the mechanical performance of all the short models produced up to now
Recommended from our members
Assembly of a Mechanical Model of MQXFB, the 7.2-m-Long Low-β Quadrupole for the High-Luminosity LHC Upgrade
The Nb Sn low-β quadrupole MQXF is being developed as a part of the High-Luminosity large hadron collider (LHC) upgrade project. The magnet will be produced in two different configurations, sharing the same cross section but with different lengths. A 7.2-m mechanical model of MQXFB was recently assembled at european organization for nuclear research (CERN) with one copper coil, two low-grade coils, and one rejected coil. Coil dimensions were measured with a portable coordinate measurement machine. The coil pack shimming was designed in order to optimize the field quality and the contacts between the coils and the collars. The azimuthal preload target was defined using the short models experience. The mechanical behavior during loading was monitored by means of strain gauges. The results demonstrated that the structure can provide the required prestress to the coils.
Flow cytometric determination of genome size in European sunbleak Leucaspius delineatus (Heckel, 1843)
The aim of this study was to compare DNA content in hepatocyte and erythrocyte nuclei of the European sunbleak, Leucaspius delineatus, in relation to nuclear and cell size by means of flow cytometry and fluorescence microscopy. The DNA standards, chicken and rainbow trout erythrocytes, were prepared in parallel with both cell types, with initial separation of liver cells in pepsin solution followed by cell filtering. Standards and investigated cells were stained with a mixture of propidium iodide, citric acid, and Nonidet P40 in the presence of RNAse, and fluorescence of at least 50,000 nuclei was analyzed by flow cytometry. Average cell size was determined by flow cytometry, using fresh cell suspension in relation to latex beads of known diameter. The size of nuclei was examined on the basis of digital micrographs obtained by fluorescence microscopy after nuclei staining with DAPI. The sunbleak’s erythrocyte nuclei contain 2.25 ± 0.06 pg of DNA, whereas the hepatocyte nuclei contain 2.46 ± 0.06 pg of DNA. This difference in DNA content was determined spectroscopically using isolated DNA from the two cell types. The modal diameters of the erythrocytes and hepatocytes were estimated to be 5.1 ± 0.2 and 22.3 ± 5.0 μm, respectively, and the corresponding modal dimensions of their nuclei (measured as surface area) were 15.2 and 21.4 μm2, respectively. The nucleoplasmic index, as calculated from diameters estimated from surface area of nuclear profiles, was 2.51 for the erythrocytes compared with 0.08 for hepatocytes
Magnetic Model of the CERN Proton Synchrotron Main Magnetic Unit
The CERN Proton Synchrotron (PS) will remain one of the key elements of the Large Hadron Collider (LHC) injector system for the next 20-25 years. Tuning the machine characteristics to the requirements for the LHC and its upgrades will require the establishment of an accurate magnetic model of the PS combined-function magnets, which is the subject of this paper. In the scope of this research, a detailed 2D quasi-static analysis of the PS magnets was performed, which allowed to investigate the magnetic field evolution and the contribution of separate magnet circuits at different field levels. An experimental validation of this new model was carried out through ad-hoc field measurements machine studies iterated with an optical model of the PS machine to recreate the measured optical parameters of the beam
- …