5,456 research outputs found

    Modulation of Thermoelectric Power of Individual Carbon Nanotubes

    Full text link
    Thermoelectric power (TEP) of individual single walled carbon nanotubes (SWNTs) has been measured at mesoscopic scales using a microfabricated heater and thermometers. Gate electric field dependent TEP-modulation has been observed. The measured TEP of SWNTs is well correlated to the electrical conductance across the SWNT according to the Mott formula. At low temperatures, strong modulations of TEP were observed in the single electron conduction limit. In addition, semiconducting SWNTs exhibit large values of TEP due to the Schottky barriers at SWNT-metal junctions.Comment: to be published in Phys. Rev. Let

    High-speed electrochemical imaging

    Get PDF
    The design, development, and application of high-speed scanning electrochemical probe microscopy is reported. The approach allows the acquisition of a series of high-resolution images (typically 1000 pixels μm–2) at rates approaching 4 seconds per frame, while collecting up to 8000 image pixels per second, about 1000 times faster than typical imaging speeds used up to now. The focus is on scanning electrochemical cell microscopy (SECCM), but the principles and practicalities are applicable to many electrochemical imaging methods. The versatility of the high-speed scan concept is demonstrated at a variety of substrates, including imaging the electroactivity of a patterned self-assembled monolayer on gold, visualization of chemical reactions occurring at single wall carbon nanotubes, and probing nanoscale electrocatalysts for water splitting. These studies provide movies of spatial variations of electrochemical fluxes as a function of potential and a platform for the further development of high speed scanning with other electrochemical imaging techniques

    Electric Field Modulation of Galvanomagnetic Properties of Mesoscopic Graphite

    Full text link
    Electric field effect devices based on mesoscopic graphite are fabricated for galvanomagnetic measurements. Strong modulation of magneto-resistance and Hall resistance as a function of gate voltage is observed as sample thickness approaches the screening length. Electric field dependent Landau level formation is detected from Shubnikov de Haas oscillations in magneto-resistance. The effective mass of electron and hole carriers has been measured from the temperature dependant behavior of these oscillations.Comment: 4 pages, 4 figures included, submitted to Phys. Rev. Let

    FMEA of MR-Only Treatment Planning in the Pelvis

    Get PDF
    Purpose: To evaluate the implementation of a magnetic resonance (MR)-only workflow (ie, implementing MR simulation as the primary planning modality) using failure mode and effects analysis (FMEA) in comparison with a conventional multimodality (MR simulation in conjunction with computed tomography simulation) workflow for pelvis external beam planning. Methods and Materials: To perform the FMEA, a multidisciplinary 9-member team was assembled and developed process maps, identified potential failure modes (FMs), and assigned numerical values to the severity (S), frequency of occurrence (O), and detectability (D) of those FMs. Risk priority numbers (RPNs) were calculated via the product of S, O, and D as a metric for evaluating relative patient risk. An alternative 3-digit composite number (SOD) was computed to emphasize high-severity FMs. Fault tree analysis identified the causality chain leading to the highest-severity FM. Results: Seven processes were identified, 3 of which were shared between workflows. Image fusion and target delineation subprocesses using the conventional workflow added 9 and 10 FMs, respectively, with 6 RPNs \u3e100. By contrast, synthetic computed tomography generation introduced 3 major subprocesses and propagated 46 unique FMs, 15 with RPNs \u3e100. For the conventional workflow, the largest RPN scores were introduced by image fusion (RPN range, 120-192). For the MR-only workflow, the highest RPN scores were from inaccuracies in target delineation resulting from misinterpretation of MR images (RPN = 240) and insufficient management of patient- and system-level distortions (RPN = 210 and 168, respectively). Underestimation (RPN = 140) or overestimation (RPN = 192) of bone volume produced higher RPN scores. The highest SODs for both workflows were related to changes in target location because of internal anatomy changes (conventional = 961, MR-only = 822). Conclusions: FMEA identified areas for mitigating risk in MR-only pelvis RTP, and SODs identified high-severity process modes. Efforts to develop a quality management program to mitigate high FMs are underway

    Atomically Thin Resonant Tunnel Diodes built from Synthetic van der Waals Heterostructures

    Full text link
    Vertical integration of two-dimensional van der Waals materials is predicted to lead to novel electronic and optical properties not found in the constituent layers. Here, we present the direct synthesis of two unique, atomically thin, multi-junction heterostructures by combining graphene with the monolayer transition-metal dichalocogenides: MoS2, MoSe2, and WSe2.The realization of MoS2-WSe2-Graphene and WSe2-MoSe2-Graphene heterostructures leads toresonant tunneling in an atomically thin stack with spectrally narrow room temperature negative differential resistance characteristics

    Focusing light inside scattering media with magnetic-particle-guided wavefront shaping

    Get PDF
    Optical scattering has traditionally limited the ability to focus light inside scattering media such as biological tissue. Recently developed wavefront shaping techniques promise to overcome this limit by tailoring an optical wavefront to constructively interfere at a target location deep inside scattering media. To find such a wavefront solution, a “guidestar” mechanism is required to identify the target location. However, developing guidestars of practical usefulness is challenging, especially in biological tissue, which hinders the translation of wavefront shaping techniques. Here, we demonstrate a guidestar mechanism that relies on magnetic modulation of small particles. This guidestar method features an optical modulation efficiency of 29% and enables micrometer-scale focusing inside biological tissue with a peak intensity-to-background ratio (PBR) of 140; both numbers are one order of magnitude higher than those achieved with the ultrasound guidestar, a popular guidestar method. We also demonstrate that light can be focused on cells labeled with magnetic particles, and to different target locations by magnetically controlling the position of a particle. Since magnetic fields have a large penetration depth even through bone structures like the skull, this optical focusing method holds great promise for deep-tissue applications such as optogenetic modulation of neurons, targeted light-based therapy, and imaging

    Development and evaluation of a novel MR-compatible pelvic end-to-end phantom

    Get PDF
    MR-only treatment planning and MR-IGRT leverage MRI\u27s powerful soft tissue contrast for high-precision radiation therapy. However, anthropomorphic MR-compatible phantoms are currently limited. This work describes the development and evaluation of a custom-designed, modular, pelvic end-to-end (PETE) MR-compatible phantom to benchmark MR-only and MR-IGRT workflows. For construction considerations, subject data were assessed for phantom/skeletal geometry and internal organ kinematics to simulate average male pelvis anatomy. Various materials for the bone, bladder, and rectum were evaluated for utility within the phantom. Once constructed, PETE underwent CT-SIM, MR-Linac, and MR-SIM imaging to qualitatively assess organ visibility. Scans were acquired with various bladder and rectal volumes to assess component interactions, filling capabilities, and filling reproducibility via volume and centroid differences. PETE simulates average male pelvis anatomy and comprises an acrylic body oval (height/width = 23.0/38.1 cm) and a cast-mold urethane skeleton, with silicone balloons simulating bladder and rectum, a silicone sponge prostate, and hydrophilic poly(vinyl alcohol) foam to simulate fat/tissue separation between organs. Access ports enable retrofitting the phantom with other inserts including point/film-based dosimetry options. Acceptable contrast was achievable in CT-SIM and MR-Linac images. However, the bladder was challenging to distinguish from background in CT-SIM. The desired contrast for T1-weighted and T2-weighted MR-SIM (dark and bright bladders, respectively) was achieved. Rectum and bone exhibited no MR signal. Inputted volumes differed by(CT-SIM) and bladder (MR-SIM) volumes. Increasing bladder and rectal volumes induced organ displacements and shape variations. Reproduced volumes differed b

    Inter-individual Differences in Tolerance to a Simulated Hemorrhage Challenge During Heat Stress: Cerebrovascular Control

    Get PDF
    A high degree of inter-individual variability exists in heat stress (HS) -induced reductions in orthostatic tolerance relative to normothermia (NT), which may be associated with HS-mediated reductions in cerebral perfusion, and thus mechanisms of cerebrovascular control during hypotensive challenges. This study tested two hypotheses; 1) the magnitude of increase in cerebral autoregulation (CA) would be negatively correlated with the difference in tolerance to graded lower body negative pressure (LBNP) 30 [assessed with a cumulative stress index (CSI)] during HS relative to NT (CSIdiff), and 2) cerebrovascular sensitivity to HS-induced hypocapnia would be positively correlated with CSIdiff. Subjects (N=13) were exposed to LBNP on two occasions (NT and HS) separated by \u3e72h to assess CSI. On a third day, indices of CA were assessed during NT and HS by spectral and transfer function analyses, and cerebrovascular sensitivity to changes in PaCO2 was determined during NT, HS, and HS+LBNP (-20 mm Hg; HSLBNP). Estimates of CA were improved during HS compared to NT (P0.05). Hyperventilation-induced hypocapnia reduced cerebral vascular conductance (CVCi) during HS and HSLBNP relative to NT (P0.05 for all). In summary, HS augments mechanisms of cerebrovascular control to protect against orthostatic challenges; however, individual differences in these responses do not predict tolerance to a simulated hemorrhage when internal temperature is elevated
    • …
    corecore