362 research outputs found

    Transition-metal interactions in aluminum-rich intermetallics

    Full text link
    The extension of the first-principles generalized pseudopotential theory (GPT) to transition-metal (TM) aluminides produces pair and many-body interactions that allow efficient calculations of total energies. In aluminum-rich systems treated at the pair-potential level, one practical limitation is a transition-metal over-binding that creates an unrealistic TM-TM attraction at short separations in the absence of balancing many-body contributions. Even with this limitation, the GPT pair potentials have been used effectively in total-energy calculations for Al-TM systems with TM atoms at separations greater than 4 AA. An additional potential term may be added for systems with shorter TM atom separations, formally folding repulsive contributions of the three- and higher-body interactions into the pair potentials, resulting in structure-dependent TM-TM potentials. Towards this end, we have performed numerical ab-initio total-energy calculations using VASP (Vienna Ab Initio Simulation Package) for an Al-Co-Ni compound in a particular quasicrystalline approximant structure. The results allow us to fit a short-ranged, many-body correction of the form a(r_0/r)^{b} to the GPT pair potentials for Co-Co, Co-Ni, and Ni-Ni interactions.Comment: 18 pages, 5 figures, submitted to PR

    Etiology of pure tricuspid regurgitation based on anular circumference and leaflet area: Analysis of 45 necropsy patients with clinical and morphologic evidence of pure tricuspid regurgitation

    Get PDF
    Despite recent renewed interest in the detection of tricuspid valve regurgitation by echocardiographic and Doppler techniques, little morphologic information is available on dysfunctioning tricuspid valves. This report describes 45 necropsy patients with clinical and morphologic evidence of pure(no element of stenosis) tricuspid regurgitation and provides morphometric observations (anular circumference, leaflet area) of the tricuspid valve useful in determining the etiology of pure tricuspid regurgitation. Of 45 patients, 24 (53%) had pure tricuspid regurgitation resulting from an anatomically abnormal valve (prolap9e in 7, papillary muscle dysfunction in 6, rheumatic disease in 5, Ebstein's anomaly in 3, infective endocarditis in 2, carcinoid tumor in 1), and 21(47%) had an anatomically normal valve with systolic pulmonary artery hypertension (cor pulmonary in 12, mitral stenosis in 9). Anular circumference was dilated (> 12 cm) in patients with various causes of pulmonary hypertension, floppy valve and Ebstein's tricuspid anomaly. Leaflet area was increased in floppy valve and Ebstein's anomaly.Of the 45 patients, 24 had pulmonary systolic artery pressure measurements available for correlation with tricuspid valve morphology. Pulmonary artery pressures accurately predicted morphologically normal from abnormal valves in 16 patients (89 %). Morphologic overlap occurred in six patients with pulmonary pressures of 41 to 54 mm Hg. Of these six, the additional knowledge of normal or dilated anular circumference correctly separated valves with normal and abnormal leaflets

    High-field MR imaging in pediatric congenital heart disease: Initial results

    Get PDF
    BackgroundComprehensive assessment of pediatric congenital heart disease (CHD) at any field strength mandates evaluation of both vascular and dynamic cardiac anatomy for which diagnostic quality contrast-enhanced magnetic resonance angiography (CEMRA) and cardiac cine are crucial.ObjectiveTo determine whether high-resolution (HR) CEMRA and steady-state free precession (SSFP) cine can be performed reliably at 3.0 T in children with CHD and to compare the image quality to similar techniques performed at 1.5 T.Materials and methodsTwenty-eight patients with a median age of 5 months and average weight 9.0 ± 7.8 kg with suspected or known CHD were evaluated at 3.0 T. SSFP cine (n = 86 series) and HR-CEMRA (n = 414 named vascular segments) were performed and images were scored for image quality and artifacts. The findings were compared to those of 28 patients with CHD of similar weight who were evaluated at 1.5 T.ResultsOverall image quality on HR-CEMRA was rated as excellent or good in 96% (397/414) of vascular segments at 3.0 T (k = 0.49) and in 94% (349/371) of vascular segments at 1.5 T (k = 0.36). Overall image quality of SSFP was rated excellent or good in 91% (78/86) of cine series at 3.0 T (k = 0.55) and in 81% (87/108) at 1.5 T (k = 0.47). Off-resonance artifact was common at both field strengths, varied over the cardiac cycle and was more prevalent at 3.0 T. At 3.0 T, off-resonance dark band artifact on SSFP cine was absent in 3% (3/86), mild in 69% (59/86), moderate in 27% (23/86) and severe in 1% (1/86) of images; at 1.5 T, dark band artifact was absent in 16% (17/108), mild in 69% (75/108), moderate in 12% (13/108) and severe in 3% (3/108) of cine images. The signal-to-noise ratio and contrast-to-noise ratio of both SSFP cine and HR-CEMRA images were significantly higher at 3.0 T than at 1.5 T (P < 0.001).ConclusionSignal-to-noise ratio and contrast-to-noise ratio of high-resolution contrast-enhanced magnetic resonance angiography and SSFP cine were higher at 3.0 T than at 1.5 T. Artifacts on SSFP cine were cardiac phase specific and more prevalent at 3.0 T such that frequency-tuning was required in one-third of exams. In neonates, high spatial resolution CEMRA was highly reliable in defining extracardiac vascular anatomy

    Salvage of renal transplant with vacuum-assisted thrombectomy of large iliocaval and allograft venous outflow thrombus

    Get PDF
    A 47-year-old male with a remote renal transplant due to pediatric glomerulonephritis on oral anticoagulation for symptomatic deep venous thrombosis and pulmonary emboli presented with sudden hip and groin pain. The patient was found to have a spinal epidural hematoma, underwent reversal of anticoagulation, and subsequently developed worsening renal function. Imaging revealed occlusive iliocaval venous thrombosis with extension to the renal allograft. Given risk of epidural hematoma expansion, the patient was deemed high risk for thrombolysis. The AngioVac system was used for single session thrombus removal. The patient’s renal function improved and no focal neurologic sequelae was noted postprocedure. Six-month follow-up showed persistent vessel patency

    Matching Three-Dimensional Objects Using a Relational Paradigm

    Get PDF
    A relational model for describing three-dimensional objects has been designed and implemented as part of a database system. The models which provide rough descriptions to be used at the top level of a hierarchy for describing objects, were designed for initial matching attempts on an unknown object. The descriptions are in terms of the set of simple parts of the objects. Simple parts can be sticks (long, thin parts), plates (flat, wide parts) , and blobs (parts that have three significant dimensions). The relations include an attribute-value table for global properties of the object, the properties of the simple parts, binary connection and support relationships, ternary connection relationships, parallel relationships, perpendicular relationships, and binary constraints. An important use of the system is to characterize the similarity and differences between three-dimensional objects. Toward this end, we have defined a measure of relational similarity between three-dimensional object models and a measure of feature similarity, based only on Euclidean distance between attribute-value tables. In a series of experiments, we compare the results of using the two different similarity measures and conclude that the relational similarity is much more powerful than the feature similarity and should be used when grouping the objects in the database for fast access

    Balloon-occluded middle adrenal artery embolization and percutaneous microwave ablation of a metastatic adrenal tumor from renal cell carcinoma

    Get PDF
    Renal cell carcinomas present with locally advanced or metastatic disease in 25% of patients. Thermal ablation may be considered in selected patients with single-site or oligometastatic disease in selected patients. We describe single-session transarterial particle embolization with the assistance of a balloon-occlusion catheter and microwave ablation of a large hypervascular adrenal metastasis using cone beam CT and fluoroscopic XperGuide needle guidance

    Aortoesophageal fistula involving the central aortic arch salvaged with emergent percutaneous TEVAR, great vessel coverage and in vivo graft fenestration

    Get PDF
    Immediate intervention is needed for aortoesophageal fistulas (AEF), a rare but highly lethal cause of massive gastrointestinal hemorrhage. Emergent thoracic endovascular aortic repair (TEVAR) is considered first-line treatment for massive bleeding from AEFs. We describe an unusual and challenging case of TEVAR coverage of an AEF involving the central aortic arch immediately followed by in vivo endograft fenestration to regain arch vessel perfusion. In vivo fenestration, currently a procedure for emergency or investigational purposes only, was shown to be life saving in our case. The main complications associated with the procedure included stroke and infection, requiring esophagectomy and cervical diversion as well as ongoing antibiotic treatment

    Effective action and motion of a cosmic string

    Full text link
    We examine the leading order corrections to the Nambu effective action for the motion of a cosmic string, which appear at fourth order in the ratio of the width to radius of curvature of the string. We determine the numerical coefficients of these extrinsic curvature corrections, and derive the equations of motion of the worldsheet. Using these equations, we calculate the corrections to the motion of a collapsing loop, a travelling wave, and a helical breather. From the numerical coefficients we have calculated, we discuss whether the string motion can be labelled as `rigid' or `antirigid,' and hence whether cusp or kink formation might be suppressed or enhanced.Comment: 24 pages revtex, 12 figure

    Associations between animal and herd management factors, serological response to three respiratory pathogens and pluck lesions in finisher pigs on a farrow-to-finish farm

    Get PDF
    peer-reviewedBackground Serological screening is a common method to monitor antibody response to pathogen exposure, but results could vary due to several factors. This study aimed to quantify animal and management related factors associated with variation in antibody levels in finisher pigs at slaughter, in an Irish farrow-to-finish farm endemically infected with Actinobacillus pleuropneumonia (App), Mycoplasma hyopneumoniae (Mhyo) and swine influenza virus (SIV). A second objective was to estimate differences in antibody levels in pigs presenting pluck lesions. This was an observational study whereby pigs were managed as per routine farm practice. Data on sow parity, number of born alive (NBA) pigs per litter, cross-fostering status, birth and weaning body weight were recorded from 1016 pigs born from one farrowing batch. At slaughter, blood samples were collected for serological analysis and pigs were inspected for presence of enzootic pneumonia (EP)-like lesions, pleurisy, pericarditis and heart condemnations. Pigs were retrospectively classified into three production flows, depending on time spent in each production stage: flow 1 (F1; pigs followed the normal production flow); flow 2 (F2; pigs which were delayed by 1 week from advancing forward); and flow 3 (F3; pigs delayed by > 1 week from advancing forward). A nested case-control design was applied by matching pigs from each flow by sow parity, birth weight and NBA. Results Pigs born from primiparous sows had higher antibody levels for App than those born to parity ≥5 sows (P  0.05). Pigs in F1 had lower antibody levels for App but higher antibody levels for SIV than F2 and F3 pigs (P  0.05), except for increased antibody levels for Mhyo when EP-like lesions were present (P = 0.006). Conclusion Results indicate that offspring from primiparous sows develop higher antibody levels for App IV toxin when exposed to this disease and that enforcement of a strict all-in/all-out production system would reduce on-farm disease circulation. A high percentage of pigs were affected with EP-like lesions which were associated with higher antibody levels for Mhyo
    • …
    corecore