1,815 research outputs found

    Extended x-ray absorption fine structure study of porous GaSb formed by ion implantation

    Get PDF
    Porous GaSb has been formed by Ga ion implantation into crystalline GaSb substrates at either room temperature or −180 °C. The morphology has been characterized using scanning electron microscopy and the atomic structure was determined using extended x-ray absorption fine structure spectroscopy. Room-temperature implantation at low fluences leads to the formation of ∼20-nm voids though the material remains crystalline. Higher fluences cause the microstructure to evolve into a network of amorphous GaSb rods ∼15 nm in diameter. In contrast, implantation at −180 °C generates large, elongated voids but no rods. Upon exposure to air, the surface of the porous material is readily oxidized yielding Ga₂O₃ and metallic Sb precipitates, the latter resulting from the reduction of unstable Sb₂O₃. We consider and discuss the atomic-scale mechanisms potentially operative during the concurrent crystalline-to-amorphous and continuous-to-porous transformations

    Structural and elastic characterization of Cu-implanted SiO₂ films on Si(100) substrates

    Get PDF
    Cu-implanted SiO₂ films on Si(100) have been studied and compared to unimplanted SiO₂ on Si(100) using x-ray methods, transmission electron microscopy, Rutherford backscattering, and Brillouin spectroscopy. The x-ray results indicate the preferred orientation of Cu {111} planes parallel to the Si substrate surface without any directional orientation for Cu-implanted SiO₂∕Si(100) and for Cu-implanted and annealedSiO₂∕Si(100). In the latter case, transmission electron microscopy reveals the presence of spherical nanocrystallites with an average size of ∼2.5 nm. Rutherford backscattering shows that these crystallites (and the Cu in the as-implanted film) are largely confined to depths of 0.4−1.2 μm below the film surface. Brillouin spectra contain peaks due to surface, film-guided and bulk acoustic modes. Surface (longitudinal) acoustic wave velocities for the implanted films were ∼7% lower (∼2% higher) than for unimplanted SiO₂∕Si(100). Elastic constants were estimated from the acoustic wave velocities and film densities. C₁₁ (C₄₄) for the implanted films was ∼10% higher (lower) than that for the unimplanted film. The differences in acoustic velocities and elastic moduli are ascribed to implantation-induced compaction and/or the presence of Cu in the SiO₂ film.B.J. and M.C.R. are grateful for financial support from the Australian Synchrotron Research Program, funded by the Commonwealth of Australia. M.C.R. would also like to thank the Australian Research Council for their financial support. The financial support of the Natural Sciences and Engineering Research Council of Canada NSERC is gratefully acknowledged by G.T.A. and J.S

    Formation and structural characterization of Ni nanoparticles embedded in SiO₂

    Get PDF
    Face-centered cubic Ni nanoparticles were formed in SiO₂ by ion implantation and thermal annealing. Small-angle x-ray scattering in conjunction with transmission electron microscopy was used to determine the nanoparticle size as a function of annealing temperature, whereas the local atomic structure was measured with x-ray absorption spectroscopy. The influence of finite-size effects on the nanoparticle structural properties was readily apparent and included a decrease in coordination number and bond length and an increase in structural disorder for decreasing nanoparticle size. Such results are consistent with the non-negligible surface-to-volume ratio characteristic of nanoparticles. In addition, temperature-dependent x-ray absorption spectroscopy measurements showed the mean vibrational frequency (as obtained from the Einstein temperature) decreased with decreasing nanoparticle size. This reduction was attributed to the greater influence of the loosely bound, under-coordinated surface atoms prevailing over the effects of capillary pressure, the former enhancing the low frequency modes of the vibrational density of statesThis work was financially supported by the Australian Synchrotron and the Australian Research Council with access to equipment provided by the Australian Nanofabrication Facility

    High-sensitivity microfluidic calorimeters for biological and chemical applications

    Get PDF
    High-sensitivity microfluidic calorimeters raise the prospect of achieving high-throughput biochemical measurements with minimal sample consumption. However, it has been challenging to realize microchip-based calorimeters possessing both high sensitivity and precise sample-manipulation capabilities. Here, we report chip-based microfluidic calorimeters capable of characterizing the heat of reaction of 3.5-nL samples with 4.2-nW resolution. Our approach, based on a combination of hard- and soft-polymer microfluidics, provides both exceptional thermal response and the physical strength necessary to construct high-sensitivity calorimeters that can be scaled to automated, highly multiplexed array architectures. Polydimethylsiloxane microfluidic valves and pumps are interfaced to parylene channels and reaction chambers to automate the injection of analyte at 1 nL and below. We attained excellent thermal resolution via on-chip vacuum encapsulation, which provides unprecedented thermal isolation of the minute microfluidic reaction chambers. We demonstrate performance of these calorimeters by resolving measurements of the heat of reaction of urea hydrolysis and the enthalpy of mixing of water with methanol. The device structure can be adapted easily to enable a wide variety of other standard calorimeter operations; one example, a flow calorimeter, is described

    Direct observation of substitutional Ga after ion implantation in Ge by means of extended x-ray absorption fine structure

    Get PDF
    We present an experimental lattice location study of Ga atoms in Ge after ion implantation at elevated temperature (250°C). Using extended x-rayabsorption fine structure (EXAFS) experiments and a dedicated sample preparation method, we have studied the lattice location of Ga atoms in Ge with a concentration ranging from 0.5 at. % down to 0.005 at. %. At Ga concentrations ≤0.05 at.%, all Ga dopants are substitutional directly after ion implantation, without the need for post-implantation thermal annealing. At higher Ga concentrations, a reduction in the EXAFS amplitude is observed, indicating that a fraction of the Ga atoms is located in a defective environment. The local strain induced by the Ga atoms in the Ge matrix is independent of the Ga concentration and extends only to the first nearest neighbor Ge shell, where a 1% contraction in bond length has been measured, in agreement with density functional theory calculations.We acknowledge the support from the Research Foundation Flanders, the epi-team from imec, the KU Leuven GOA 09/06 project, the IUAP program P6/42 and the Australian Research Council. S.C. acknowledges support from OCAS NV by an OCAS-endowed chair at Ghent University

    Anal incontinence after vaginal delivery or cesarean section.

    Get PDF
    INTRODUCTION: Uncertainties remain as to whether cesarean section is protective for short and long term development of anal incontinence. Our aim was to explore whether women who had only delivered vaginally were at greater risk of anal incontinence compared to nulliparous women and women who had undergone caesarean sections only. MATERIAL AND METHODS: Background information, medical history and data on anal incontinence (defined as fecal or flatus incontinence weekly or more) reported by women participating in a large population-based health survey in Norway (HUNT 3) during the period October 2006-June 2008, was collected and linked to data from the Medical Birth Registry of Norway. Anal incontinence prevalence was calculated and multivariable logistic regression analyses were applied. RESULTS: Mean age amongst the 12.567 women was 49.9 years. Age and educational level were similar in women with caesarean sections only and those with vaginal delivery and obstetric anal sphincter injuries (OASIS). Nulliparas and women with vaginal delivery and no OASIS were older and had higher educational achievements. One in four women with OASIS reported anal incontinence compared to one in six amongst the other women(p<.001). Age, educational level, diarrhea, constipation, birthweight and OASIS increased the risk of anal incontinence in all women. Parity was associated with anal incontinence in parous women only. No differences were found for fecal urgency. CONCLUSIONS: Women with vaginal deliveries complicated by OASIS were at increased risk of anal incontinence. However, no increased risk of anal incontinence was found in nulliparous women or women with cesarean sections only or vaginal deliveries not complicated by OASIS

    Amorphization of Cu nanoparticles: effects on surface plasmon resonance

    No full text
    Crystalline copper nanoparticles (NPs) were formed in silica by multi-energy MeV ion implantations and then transformed to amorphous NPs by irradiation with 5 MeV Sn3+ ions. Optical absorptionspectra of both the phases were evaluated in the ultra-violet to near-infrared regions. Compared with corresponding crystalline NPs of the same mean diameter, the amorphous NPs showed a low-energy shift of the surface plasmon resonance around 2.2 eV and less prominent absorptionstructure around 4 eV. These differences are explained by a strongly reduced electron mean-free-path in the amorphous NPs due to the loss of lattice periodicity

    Quality of life and well-being of carers of people with dementia: are there differences between working and nonworking carers? Results from the IDEAL program

    Get PDF
    The aim of this study was to identify the differences in quality of life (QoL) and well-being between working and nonworking dementia carers and the relative contribution of psychological characteristics, caregiving experience, and social support. Multiple regressions modeled the contribution of working status, caregiver experiences, and psychological and social resources to carer QoL (EQ-5D) and well-being (WHO-5). After controlling for age, gender, carer–dyad relationship, and severity of dementia, working status contributed significant variance to EQ-5D (2%) but not to WHO-5 scores. Independent of working status, higher self-esteem and reduced stress contributed to variance in both models. Self-efficacy, social support, and positive perceptions of caregiving additionally contributed to higher WHO-5 scores. Working status associated with higher EQ-5D QoL; this may reflect the sustained sense of independence associated with supported work opportunities for carers. Outside of working status, the findings support the importance of psychological and social factors as targets to improved mental health for dementia carers