681 research outputs found

    Design optimization of transonic airfoils

    Get PDF
    Numerical optimization procedures were considered for the design of airfoils in transonic flow based on the transonic small disturbance (TSD) and Euler equations. A sequential approximation optimization technique was implemented with an accurate approximation of the wave drag based on the Nixon's coordinate straining approach. A modification of the Euler surface boundary conditions was implemented in order to efficiently compute design sensitivities without remeshing the grid. Two effective design procedures producing converged designs in approximately 10 global iterations were developed: interchanging the role of the objective function and constraint and the direct lift maximization with move limits which were fixed absolute values of the design variables

    Electrical and structural degradation of GaN high electron mobility transistors under high-power and high-temperature Direct Current stress

    Get PDF
    We have stressed AlGaN/GaN HEMTs (High Electron Mobility Transistors) under high-power and high-temperature DC conditions that resulted in various levels of device degradation. Following electrical stress, we conducted a well-established three-step wet etching process to remove passivation, gate and ohmic contacts so that the device surface can be examined by SEM and AFM. We have found prominent pits and trenches that have formed under the gate edge on the drain side of the device. The width and depth of the pits under the gate edge correlate with the degree of drain current degradation. In addition, we also found visible erosion under the full extent of the gate. The depth of the eroded region averaged along the gate width under the gate correlated with channel resistance degradation. Both electrical and structural analysis results indicate that device degradation under high-power DC conditions is of a similar nature as in better understood high-voltage OFF-state conditions. The recognition of a unified degradation mechanism provides impetus to the development of a degradation model with lifetime predictive capabilities for a broad range of operating conditions spanning from OFF-state to ON-state.United States. Office of Naval Research.Design-for-Reliability Initiative for Future Technologies. Multidisciplinary University Research Initiative

    Extraction of the Spin Glass Correlation Length

    Full text link
    The peak of the spin glass relaxation rate, S(t)=d{-M_{TRM}(t,t_w)}/H/{d ln t}, is directly related to the typical value of the free energy barrier which can be explored over experimental time scales. A change in magnetic field H generates an energy E_z={N_s}{X_fc}{H^2} by which the barrier heights are reduced, where X_{fc} is the field cooled susceptibility per spin, and N_s is the number of correlated spins. The shift of the peak of S(t) gives E_z, generating the correlation length, Ksi(t,T), for Cu:Mn 6at.% and CdCr_{1.7}In_{0.3}S_4. Fits to power law dynamics, Ksi(t,T)\propto {t}^{\alpha(T)} and activated dynamics Ksi(t,T) \propto {ln t}^{1/psi} compare well with simulation fits, but possess too small a prefactor for activated dynamics.Comment: 4 pages, 4 figures. Department of Physics, University of California, Riverside, California, and Service de Physique de l'Etat Condense, CEA Saclay, Gif sur Yvette, France. To appear in Phys. Rev. Lett. January 4, 199

    Elastic-plastic deformation of a metal-matrix composite coupon with a center slot

    Get PDF
    A comprehensive experimental analysis of deformations of the surface of a metal-matrix specimen is reported. The specimen is a 6-ply 0 + or - 45 sub s boron-aluminum tensile coupon with a central slot. Moire interferometry is used for high-sensitivity whole-field measurements of in-plane displacements. Normal and shear strains are calculated from displacement gradients. Displacement fields are analyzed at various load levels from 15% to 95% of the failure load. Deformations of the boron fibers could be distinguished from those of the matrix. Highly localized plastic slip zones occur tangent to the ends of the slot. Shear strains and concurrent transverse compressive strains in the slip zones reach approximately 10% and 1%, respectively. Upon unloading, elastic recovery in surrounding regions causes a reverse plastic shear strain in the slip zone of about 4%. Longitudinal normal strains on the unslotted ligament peak at the slot boundary at about 1% strain. The strain concentration factor at the end of the slot decreases with load level and the advance of plasticity

    Double polarization hysteresis loop induced by the domain pinning by defect dipoles in HoMnO3 epitaxial thin films

    Full text link
    We report on antiferroelectriclike double polarization hysteresis loops in multiferroic HoMnO3 thin films below the ferroelectric Curie temperature. This intriguing phenomenon is attributed to the domain pinning by defect dipoles which were introduced unintentionally during film growth process. Electron paramagnetic resonance suggests the existence of Fe1+ defects in thin films and first principles calculations reveal that the defect dipoles would be composed of oxygen vacancy and Fe1+ defect. We discuss migration of charged point defects during film growth process and formation of defect dipoles along ferroelectric polarization direction, based on the site preference of point defects. Due to a high-temperature low-symmetry structure of HoMnO3, aging is not required to form the defect dipoles in contrast to other ferroelectrics (e.g., BaTiO3).Comment: 4 figure

    Risk of haemolytic uraemic syndrome caused by shiga-toxin-producing Escherichia coli infection in adult women in Japan

    Get PDF
    Shiga-toxin-producing Escherichia coli (STEC) infections usually cause haemolytic uraemic syndrome (HUS) equally in male and female children. This study investigated the localization of globotriaosylceramide (Gb3) in human brain and kidney tissues removed from forensic autopsy cases in Japan. A fatal case was used as a positive control in an outbreak of diarrhoeal disease caused by STEC O157:H7 in a kindergarten in Urawa in 1990. Positive immunodetection of Gb3 was significantly more frequent in female than in male distal and collecting renal tubules. To correlate this finding with a clinical outcome, a retrospective analysis of the predictors of renal failure in the 162 patients of two outbreaks in Japan was performed: one in Tochigi in 2002 and the other in Kagawa Prefecture in 2005. This study concludes renal failure, including HUS, was significantly associated with female sex, and the odds ratio was 4·06 compared to male patients in the two outbreaks. From 2006 to 2009 in Japan, the risk factor of HUS associated with STEC infection was analysed. The number of males and females and the proportion of females who developed HUS were calculated by age and year from 2006 to 2009. In 2006, 2007 and 2009 in adults aged >20 years, adult women were significantly more at risk of developing HUS in Japan
    corecore