14 research outputs found

    The EGFR Is Required for Proper Innervation to the Skin

    Get PDF
    EGFR family members are essential for proper peripheral nervous system development. A role for EGFR itself in peripheral nervous system development in vivo, however, has not been reported. We investigated whether EGFR is required for cutaneous innervation using Egfr null and skin-targeted Egfr mutant mice. Neuronal markers; including PGP9.5, GAP-43, acetylated tubulin, and neurofilaments; revealed that Egfr null dorsal skin was hyperinnervated with a disorganized pattern of innervation. In addition, receptor subtypes such as lanceolate endings were disorganized and immature. To determine whether the hyperinnervation phenotype resulted from a target-derived effect of loss of EGFR, mice lacking EGFR expression in the cutaneous epithelium were examined. These mice retained other aspects of the cutaneous Egfr null phenotype but exhibited normal innervation. The sensory deficits in Egfr null dorsal skin were not associated with any abnormality in the morphology or density of dorsal root ganglion (DRG) neurons or Schwann cells. However, explant and dissociated cell cultures of DRG revealed more extensive branching in Egfr null cultures. These data demonstrate that EGFR is required for proper cutaneous innervation during development and suggest that it limits axonal outgrowth and branching in a DRG-autonomous manner

    Percutaneous ultrasound guided implantation of VX2 for creation of a rabbit hepatic tumor model.

    No full text
    Creation of a VX2 tumor model has traditionally required a laparotomy and surgical implantation of tumor fragments. Open surgical procedures are invasive and require long procedure times and recovery that can result in post-operative morbidity and mortality. The purpose of this study is to report the results of a percutaneous ultrasound guided method for creation of a VX2 model in rabbit livers. A total of 27 New Zealand white rabbits underwent a percutaneous ultrasound guided approach, where a VX2 tumor fragment was implanted in the liver. Magnetic resonance imaging was used to assess for tumor growth and necropsy was performed to determine rates of tract seeding and metastatic disease. Ultrasound guided tumor implantation was successful in all 27 rabbits. One rabbit died 2 days following the implantation procedure. Two rabbits had no tumors seen on follow-up imaging. Therefore, tumor development was seen in 24/26 (92%) rabbits. During the follow-up period, tract seeding was seen in 8% of rabbits and 38% had extra-hepatic metastatic disease. Therefore, percutaneous ultrasound guided tumor implantation safely provides reliable tumor growth for establishing hepatic VX2 tumors in a rabbit model with decreased rates of tract seeding, compared to previously reported methods

    Ultrasound guided implantation.

    No full text
    <p>(A) Using ultrasound guidance, a 17 gauge coaxial introducer (arrow) is advanced into the liver. The sharp inner stylet is removed and a small tumor fragment (3-4mm<sup>3</sup>) is placed in the hub of the introducer and pushed with the blunt stylet. (B) Post implantation US image reveals a small focus of hyperechogenicity (arrow) representing the tumor fragment and air.</p

    Tumor preparation.

    No full text
    <p>(A) Hind limb tumors were placed in a sterile petri dish and sliced into small tumor fragments (3-4mm<sup>3</sup>). (B) A 17 gauge coaxial introducer has a hollow core (white arrow), with two inner stylets, sharp (black arrow head) and blunt (white arrow head).</p

    MRI and Gross Pathology.

    No full text
    <p>(A) Axial T2 weighted MRI image demonstrates two T2 hyperintense lesions in the left hepatic lobe (arrow heads). (B) Explanted gross specimen reveals tumors corresponding to the lesions seen on MRI (arrow heads).</p

    Multimodality imaging to assess immediate response to irreversible electroporation in a rat liver tumor model.

    No full text
    PurposeTo compare changes on ultrasonographic (US), computed tomographic (CT), and magnetic resonance (MR) images after irreversible electroporation (IRE) ablation of liver and tumor tissues in a rodent hepatoma model.Materials and methodsStudies received approval from the institutional animal care and use committee. Forty-eight rats were used, and N1-S1 tumors were implanted in 24. Rats were divided into groups and allocated for studies with each modality. Imaging was performed in normal liver tissues and tumors before and after IRE. MR imaging was performed in one group before and after IRE after hepatic vessel ligation. US images were graded to determine echogenicity changes, CT attenuation was measured (in Hounsfield units), and MR imaging signal-to-noise ratio (SNR) was measured before and after IRE. Student t test was used to compare attenuation and SNR measurements before and after IRE (P &lt; .05 indicated a significant difference).ResultsIRE ablation produced greater alterations to echogenicity in normal tissues than in tumors. Attenuation in ablated liver tissues was reduced compared with that in control tissues (P &lt; .001), while small attenuation differences between ablated (42.11 HU ± 2.11) and control (45.14 HU ± 2.64) tumors trended toward significance (P = .052). SNR in ablated normal tissues was significantly altered after IRE (T1-weighted images: pre-IRE, 145.95 ± 24.32; post-IRE, 97.80 ± 18.03; P = .004; T2-weighted images, pre-IRE, 47.37 ± 18.31; post-IRE, 90.88 ± 37.15; P = .023). In tumors, SNR differences before and after IRE were not significant. No post-IRE signal changes were observed after hepatic vessel ligation.ConclusionIRE induces rapid changes on gray-scale US, unenhanced CT, and MR images. These changes are readily visible and may assist a performing physician to delineate ablation zones from the unablated surrounding parenchyma

    Multimodality Imaging to Assess Immediate Response to Irreversible Electroporation in a Rat Liver Tumor Model

    No full text
    PURPOSE: To compare changes on ultrasonographic (US), computed tomographic (CT), and magnetic resonance (MR) images after irreversible electroporation (IRE) ablation of liver and tumor tissues in a rodent hepatoma model. MATERIALS AND METHODS: Studies received approval from the institutional animal care and use committee. Forty-eight rats were used, and N1-S1 tumors were implanted in 24. Rats were divided into groups and allocated for studies with each modality. Imaging was performed in normal liver tissues and tumors before and after IRE. MR imaging was performed in one group before and after IRE after hepatic vessel ligation. US images were graded to determine echogenicity changes, CT attenuation was measured (in Hounsfield units), and MR imaging signal-to-noise ratio (SNR) was measured before and after IRE. Student t test was used to compare attenuation and SNR measurements before and after IRE (P < .05 indicated a significant difference). RESULTS: IRE ablation produced greater alterations to echogenicity in normal tissues than in tumors. Attenuation in ablated liver tissues was reduced compared with that in control tissues (P < .001), while small attenuation differences between ablated (42.11 HU ± 2.11) and control (45.14 HU ± 2.64) tumors trended toward significance (P = .052). SNR in ablated normal tissues was significantly altered after IRE (T1-weighted images: pre-IRE, 145.95 ± 24.32; post-IRE, 97.80 ± 18.03; P = .004; T2-weighted images, pre-IRE, 47.37 ± 18.31; post-IRE, 90.88 ± 37.15; P = .023). In tumors, SNR differences before and after IRE were not significant. No post-IRE signal changes were observed after hepatic vessel ligation. CONCLUSION: IRE induces rapid changes on gray-scale US, unenhanced CT, and MR images. These changes are readily visible and may assist a performing physician to delineate ablation zones from the unablated surrounding parenchyma. © RSNA, 2014 Online supplemental material is available for this article
    corecore