141 research outputs found

    From "Gut Feeling" to Objectivity: Machine Preservation of the Liver as a Tool to Assess Organ Viability.

    Get PDF
    PURPOSE OF REVIEW: The purpose of this review was to summarise how machine perfusion could contribute to viability assessment of donor livers. RECENT FINDINGS: In both hypothermic and normothermic machine perfusion, perfusate transaminase measurement has allowed pretransplant assessment of hepatocellular damage. Hypothermic perfusion permits transplantation of marginal grafts but as yet has not permitted formal viability assessment. Livers undergoing normothermic perfusion have been investigated using parameters similar to those used to evaluate the liver in vivo. Lactate clearance, glucose evolution and pH regulation during normothermic perfusion seem promising measures of viability. In addition, bile chemistry might inform on cholangiocyte viability and the likelihood of post-transplant cholangiopathy. SUMMARY: While the use of machine perfusion technology has the potential to reduce and even remove uncertainty regarding liver graft viability, analysis of large datasets, such as those derived from large multicenter trials of machine perfusion, are needed to provide sufficient information to enable viability parameters to be defined and validated

    Renal Normothermic Machine Perfusion:The Road Toward Clinical Implementation of a Promising Pretransplant Organ Assessment Tool

    Get PDF
    The increased utilization of high-risk renal grafts for transplantation requires optimization of pretransplant organ assessment strategies. Current decision-making methods to accept an organ for transplantation lack overall predictive power and always contain an element of subjectivity. Normothermic machine perfusion (NMP) creates near-physiological conditions, which might facilitate a more objective assessment of organ quality prior to transplantation. NMP is rapidly gaining popularity, with various transplant centers developing their own NMP protocols and renal viability criteria. However, to date, no validated sets of on-pump viability markers exist nor are there unified NMP protocols. This review provides a critical overview of the fundamentals of current renal NMP protocols and proposes a framework to approach further development of ex vivo organ evaluation. We also comment on the potential logistical implications of routine clinical use of NMP, which is a more complex procedure compared to static cold storage or even hypothermic machine perfusion. Supplemental Visual Abstract; http://links.lww.com/TP/C232

    Hypothermic Machine Perfusion in Liver Transplantation - A Randomized Trial

    Get PDF
    BACKGROUND Transplantation of livers obtained from donors after circulatory death is associated with an increased risk of nonanastomotic biliary strictures. Hypothermic oxygenated machine perfusion of livers may reduce the incidence of biliary complications, but data from prospective, controlled studies are limited. METHODS In this multicenter, controlled trial, we randomly assigned patients who were undergoing transplantation of a liver obtained from a donor after circulatory death to receive that liver either after hypothermic oxygenated machine perfusion (machine-perfusion group) or after conventional static cold storage alone (control group). The primary end point was the incidence of nonanastomotic biliary strictures within 6 months after transplantation. Secondary end points included other graft-related and general complications. RESULTS A total of 160 patients were enrolled, of whom 78 received a machine-perfused liver and 78 received a liver after static cold storage only (4 patients did not receive a liver in this trial). Nonanastomotic biliary strictures occurred in 6% of the patients in the machine-perfusion group and in 18% of those in the control group (risk ratio, 0.36; 95% confidence interval [CI], 0.14 to 0.94; P=0.03). Postreperfusion syndrome occurred in 12% of the recipients of a machine-perfused liver and in 27% of those in the control group (risk ratio, 0.43; 95% CI, 0.20 to 0.91). Early allograft dysfunction occurred in 26% of the machine-perfused livers, as compared with 40% of control livers (risk ratio, 0.61; 95% CI, 0.39 to 0.96). The cumulative number of treatments for nonanastomotic biliary strictures was lower by a factor of almost 4 after machine perfusion, as compared with control. The incidence of adverse events was similar in the two groups. CONCLUSIONS Hypothermic oxygenated machine perfusion led to a lower risk of nonanastomotic biliary strictures following the transplantation of livers obtained from donors after circulatory death than conventional static cold storage

    A multicenter randomized-controlled trial of hypothermic oxygenated perfusion (HOPE) for human liver grafts before transplantation

    Get PDF
    Background &amp; Aims: Machine perfusion is a novel method intended to optimize livers before transplantation. However, its effect on morbidity within a 1-year period after transplantation has remained unclear. Methods: In this multicenter controlled trial, we randomly assigned livers donated after brain death (DBD) for liver transplantation (LT). Livers were either conventionally cold stored (control group), or cold stored and subsequently treated by 1-2 h hypothermic oxygenated perfusion (HOPE) before implantation (HOPE group). The primary endpoint was the occurrence of at least one post-transplant complication per patient, graded by the Clavien score of ≥III, within 1-year after LT. The comprehensive complication index (CCI), laboratory parameters, as well as duration of hospital and intensive care unit stay, graft survival, patient survival, and biliary complications served as secondary endpoints. Results: Between April 2015 and August 2019, we randomized 177 livers, resulting in 170 liver transplantations (85 in the HOPE group and 85 in the control group). The number of patients with at least one Clavien ≥III complication was 46/85 (54.1%) in the control group and 44/85 (51.8%) in the HOPE group (odds ratio 0.91; 95% CI 0.50-1.66; p = 0.76). Secondary endpoints were also not significantly different between groups. A post hoc analysis revealed that liver-related Clavien ≥IIIb complications occurred less frequently in the HOPE group compared to the control group (risk ratio 0.26; 95% CI 0.07-0.77; p = 0.027). Likewise, graft failure due to liver-related complications did not occur in the HOPE group, but occurred in 7% (6 of 85) of the control group (log-rank test, p = 0.004, Gray test, p = 0.015). Conclusions: HOPE after cold storage of DBD livers resulted in similar proportions of patients with at least one Clavien ≥III complication compared to controls. Exploratory findings suggest that HOPE decreases the risk of severe liver graft-related events. Impact and implications: This randomized controlled phase III trial is the first to investigate the impact of hypothermic oxygenated perfusion (HOPE) on cumulative complications within a 12-month period after liver transplantation. Compared to conventional cold storage, HOPE did not have a significant effect on the number of patients with at least one Clavien ≥III complication. However, we believe that HOPE may have a beneficial effect on the quantity of complications per patient, based on its application leading to fewer severe liver graft-related complications, and to a lower risk of liver-related graft loss. The HOPE approach can be applied easily after organ transport during recipient hepatectomy. This appears fundamental for wide acceptance since concurring perfusion technologies need either perfusion at donor sites or continuous perfusion during organ transport, which are much costlier and more laborious. We conclude therefore that the post hoc findings of this trial should be further validated in future studies.</p

    A multicenter randomized-controlled trial of hypothermic oxygenated perfusion (HOPE) for human liver grafts before transplantation

    Get PDF
    Background &amp; Aims: Machine perfusion is a novel method intended to optimize livers before transplantation. However, its effect on morbidity within a 1-year period after transplantation has remained unclear. Methods: In this multicenter controlled trial, we randomly assigned livers donated after brain death (DBD) for liver transplantation (LT). Livers were either conventionally cold stored (control group), or cold stored and subsequently treated by 1-2 h hypothermic oxygenated perfusion (HOPE) before implantation (HOPE group). The primary endpoint was the occurrence of at least one post-transplant complication per patient, graded by the Clavien score of ≥III, within 1-year after LT. The comprehensive complication index (CCI), laboratory parameters, as well as duration of hospital and intensive care unit stay, graft survival, patient survival, and biliary complications served as secondary endpoints. Results: Between April 2015 and August 2019, we randomized 177 livers, resulting in 170 liver transplantations (85 in the HOPE group and 85 in the control group). The number of patients with at least one Clavien ≥III complication was 46/85 (54.1%) in the control group and 44/85 (51.8%) in the HOPE group (odds ratio 0.91; 95% CI 0.50-1.66; p = 0.76). Secondary endpoints were also not significantly different between groups. A post hoc analysis revealed that liver-related Clavien ≥IIIb complications occurred less frequently in the HOPE group compared to the control group (risk ratio 0.26; 95% CI 0.07-0.77; p = 0.027). Likewise, graft failure due to liver-related complications did not occur in the HOPE group, but occurred in 7% (6 of 85) of the control group (log-rank test, p = 0.004, Gray test, p = 0.015). Conclusions: HOPE after cold storage of DBD livers resulted in similar proportions of patients with at least one Clavien ≥III complication compared to controls. Exploratory findings suggest that HOPE decreases the risk of severe liver graft-related events. Impact and implications: This randomized controlled phase III trial is the first to investigate the impact of hypothermic oxygenated perfusion (HOPE) on cumulative complications within a 12-month period after liver transplantation. Compared to conventional cold storage, HOPE did not have a significant effect on the number of patients with at least one Clavien ≥III complication. However, we believe that HOPE may have a beneficial effect on the quantity of complications per patient, based on its application leading to fewer severe liver graft-related complications, and to a lower risk of liver-related graft loss. The HOPE approach can be applied easily after organ transport during recipient hepatectomy. This appears fundamental for wide acceptance since concurring perfusion technologies need either perfusion at donor sites or continuous perfusion during organ transport, which are much costlier and more laborious. We conclude therefore that the post hoc findings of this trial should be further validated in future studies.</p

    Utilization of livers donated after circulatory death for transplantation - An international comparison.

    Get PDF
    BACKGROUND AND AIM Liver graft utilization rates are a hot topic due to the worldwide organ shortage and an increasing number of transplant candidates on waiting lists. Liver perfusion techniques have been introduced in several countries, and may help to increase the organ supply, as they potentially allow the assessment of livers before use. METHODS Liver offers were counted from donation after circulatory death (DCD) donors (Maastricht-type-III) arising during the past decade in eight countries, including Belgium, France, Italy, the Netherlands, Spain, Switzerland, UK, and US. Initial DCD-type-III liver offers were correlated with accepted, recovered and implanted livers. RESULTS A total number of 34`269 DCD livers were offered, resulting in 9`780 liver transplants (28.5%). The discard rates were highest in UK and US, ranging between 70 and 80%. In contrast, much lower DCD liver discard rates, e.g., between 30-40%, were found in Belgium, France, Italy, Spain and Switzerland. In addition, large differences were recognized in the use of various machine perfusion techniques, and in terms of risk factors in the cohorts of implanted livers. For example, the median donor age and functional donor warm ischemia were highest in Italy, e.g., >40minutes, followed by Switzerland, France, and the Netherlands. Importantly, such varying risk profiles of accepted DCD livers between countries did not translate into large differences in five-year graft survival rates, which ranged between 60-82% in this analysis. CONCLUSIONS We highlight a significant number of discarded and consequently unused DCD liver offers. Countries with more routine use of in- and ex-situ machine perfusion strategies showed better DCD utilization rates without compromised outcome. IMPACT AND IMPLICATIONS A significant number of Maastricht type III DCD livers are discarded across Europe and North America today. The overall utilization rate among eight Western countries is 28.5%, but varies significantly between 18.9% and 74.2%. For example, the median DCD III liver utilization in five countries, e.g., Belgium, France, Italy, Switzerland, and Spain is 65%, in contrast to 24% in the Netherlands, UK and US. Despite this, and despite different rules and strategies for organ acceptance and preservation, the one and five-year graft survival remains currently relatively comparable among all participating countries. Factors which impact on DCD liver acceptance rates include the national pre-selections of donors, before the offer is made, as well as cutoffs for key risk factors, including donor age and donor warm ischemia time. In addition, a highly varying experience with modern machine perfusion technology is noticed. In situ and ex situ liver perfusion concepts, and assessment tools for type III DCD livers before transplantation may be one key part for the observed differences in better DCD III utilization

    A multicentre outcome analysis to define global benchmarks for donation after circulatory death liver transplantation

    Get PDF
    BACKGROUND: To identify the best possible outcomes in liver transplantation from donation after circulatory death donors (DCD) and to propose outcome values, which serve as reference for individual liver recipients or patient groups. METHODS: Based on 2219 controlled DCD liver transplantations, collected from 17 centres in North America and Europe, we identified 1012 low-risk, primary, adult liver transplantations with a laboratory MELD of ≤20points, receiving a DCD liver with a total donor warm ischemia time of ≤30minutes and asystolic donor warm ischemia time of ≤15minutes. Clinically relevant outcomes were selected and complications were reported according to the Clavien-Dindo-Grading and the Comprehensive Complication Index (CCI). Corresponding benchmark cut-offs were based on median values of each centre, where the 75(th)-percentile was considered. RESULTS: Benchmark cases represented between 19.7% and 75% of DCD transplantations in participating centers. The one-year retransplant and mortality rate was 5.23% and 9.01%, respectively. Within the first year of follow-up, 51.1% of recipients developed at least one major complication (≥Clavien-Dindo-Grade-III). Benchmark cut-offs were ≤3days and ≤16days for ICU and hospital stay, ≤66% for severe recipient complications (≥Grade-III), ≤16.8% for ischemic cholangiopathy, and ≤38.9CCI points at one-year posttransplant. Comparisons with higher risk groups showed more complications and impaired graft survival, outside the benchmark cut-offs. Organ perfusion techniques reduced the complications to values below benchmark cut-offs, despite higher graft risk. CONCLUSIONS: Despite excellent 1-year survival, morbidity in benchmark cases remains high with more than half of recipients developing severe complications during 1-year follow-up. Benchmark cut-offs targeting morbidity parameters offer a valid tool to assess the protective value of new preservation technologies in higher risk groups, and provide a valid comparator cohort for future clinical trials. LAY SUMMARY: The best possible outcomes after liver transplantation of grafts donated after circulatory death (DCD) were defined using the concept of benchmarking. These were based on 2219 liver transplantations following controlled DCD donation in 17 centres worldwide. The following benchmark cut-offs for the most relevant outcome parameters were developed: ICU and hospital stay: ≤3 and ≤16 days; primary non function: ≤2.5%; renal replacement therapy: ≤9.6%; ischemic cholangiopathy: ≤16.8% and anastomotic strictures ≤28.4%. One-year graft loss and mortality were defined as ≤14.4% and 9.6%, respectively. Donor and recipient combinations with higher risk had significantly worse outcomes. The use of novel organ perfusion technology achieved similar, good results in this high-risk group with prolonged donor warm ischemia time, when compared to the benchmark cohort
    corecore