35 research outputs found

    Swabian MOSES 2021: An interdisciplinary field campaign for investigating convective storms and their event chains

    Get PDF
    The Neckar Valley and the Swabian Jura in southwest Germany comprise a hotspot for severe convective storms, causing tens of millions of euros in damage each year. Possible reasons for the high frequency of thunderstorms and the associated event chain across compartments were investigated in detail during the hydro-meteorological field campaign Swabian MOSES carried out between May and September 2021. Researchers from various disciplines established more than 25 temporary ground-based stations equipped with state-of-the-art in situ and remote sensing observation systems, such as lidars, dual-polarization X- and C-band Doppler weather radars, radiosondes including stratospheric balloons, an aerosol cloud chamber, masts to measure vertical fluxes, autosamplers for water probes in rivers, and networks of disdrometers, soil moisture, and hail sensors. These fixed-site observations were supplemented by mobile observation systems, such as a research aircraft with scanning Doppler lidar, a cosmic ray neutron sensing rover, and a storm chasing team launching swarmsondes in the vicinity of hailstorms. Seven Intensive Observation Periods (IOPs) were conducted on a total of 21 operating days. An exceptionally high number of convective events, including both unorganized and organized thunderstorms such as multicells or supercells, occurred during the study period. This paper gives an overview of the Swabian MOSES (Modular Observation Solutions for Earth Systems) field campaign, briefly describes the observation strategy, and presents observational highlights for two IOPs

    Long-term results of radiotherapy for periarthritis of the shoulder: a retrospective evaluation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To evaluate retrospectively the results of radiotherapy for periarthritis of the shoulder</p> <p>Methods</p> <p>In 1983–2004, 141 patients were treated, all had attended at least one follow-up examination. 19% had had pain for several weeks, 66% for months and 14% for years. Shoulder motility was impaired in 137/140 patients. Nearly all patients had taken oral analgesics, 81% had undergone physiotherapy, five patients had been operated on, and six had been irradiated. Radiotherapy was applied using regular anterior-posterior opposing portals and Co-60 gamma rays or 4 MV photons. 89% of the patients received a total dose of 6 Gy (dose/fraction of 1 Gy twice weekly, the others had total doses ranging from 4 to 8 Gy. The patients and the referring doctors were given written questionnaires in order to obtain long-term results. The mean duration of follow-up was 6.9 years [0–20 years].</p> <p>Results</p> <p>During the first follow-up examination at the end of radiotherapy 56% of the patients reported pain relief and improvement of motility. After in median 4.5 months the values were 69 and 89%, after 3.9 years 73% and 73%, respectively. There were virtually no side effects. In the questionnaires, 69% of the patients reported pain relief directly after radiotherapy, 31% up to 12 weeks after radiotherapy. 56% of the patients stated that pain relief had lasted for "years", in further 12% at least for "months".</p> <p>Conclusion</p> <p>Low-dose radiotherapy for periarthropathy of the shoulder was highly effective and yielded long-lasting improvement of pain and motility without side effects.</p

    >

    No full text

    Optical beam diagnostics

    No full text

    Plasma chemistry induced by low energy electron beams

    No full text
    A table top setup for studying plasma chemical reactions is described. Low energy (15 keV) electrons are used to induce the chemical reactions. The experiments are performed with pure gases and gas mixtures at atmospheric pressure. The radiolysis of CO2 is studied as an example and a G-value of 3 was achieved for a gas flow of 14 ml/min. The experiments were performed with a total beam power of 450 mW sent into a gas cell with a volume of 40 mm3. Mass spectrometry and a spectroscopic study were used for diagnostics. A catalytic effect of xenon for the splitting of CO2 molecules was observed and supported by comparative measurements with Ar-CO2 and Ar-Xe-CO2 mixtures. The power deposition profiles in the target cell are discussed on the basis of a numerical model
    corecore