62 research outputs found
Mobile mammography in New York City: analysis of 32,350 women utilizing a screening mammogram program
Mobile mammography vans (mammovans) may help close the gap to access of breast cancer screening by providing resources to underserved communities. Minimal data exists on the populations served, the ability of mammovans to reach underserved populations, and the outcomes of participants. We sought to determine the demographic characteristics, number of breast cancers diagnosed, and number of women who used the American Italian Cancer Foundation (AICF) Mobile, No-Cost Breast Cancer Screening Program within the five boroughs of New York City. Data were collected by the AICF from 2014 to 2019 on a voluntary basis from participants at each screening location. Women aged 40 to 79 years who had not had a mammogram in the previous 12 months were invited to participate. Each participant underwent a clinical breast exam by a nurse practitioner followed by a screening mammogram. Images were read by a board-certified radiologist contracted by the AICF from Multi Diagnostic Services. There were 32,350 participants in this study. Sixty-three percent reported an annual household income ≤$25,000, and 30% did not have health insurance. More than half of participants identified as either African American (28%) or Hispanic (27%). Additional testing was performed for 5359 women found to have abnormal results on screening. In total, 68 cases of breast cancer were detected. Breast cancer disparities are multifactorial, with the greatest factor being limited access to care. Mobile, no-cost mammogram screening programs show great promise in helping to close the gap to screening access
Recommended from our members
Feasibility of contrast-enhanced mammography in women with breast implants.
Contrast-enhanced mammography (CEM) may provide an alternative to magnetic resonance imaging as a diagnostic exam in women with known or suspected breast cancer or as a screening exam in women at increased risk of breast cancer. Women with breast augmentation, either for oncologic or cosmetic reasons, may fall into this increased risk population and need safe and effective screening and diagnostic imaging tools. Here, we present our clinical practice data in order to demonstrate the feasibility of CEM in women with breast implants. An institutional review board-approved, Health Insurance Portability and Accountability Act-compliant, retrospective review of our tertiary cancer centers database yielded 104 women with breast implants who underwent 198 CEM exams from November 2014 to March 2020. All 198/198 (100%) exams were successfully completed in 104 women. Exam indications included: 174/198 (88%) screening due to increased risk, 10/198 (5%) to evaluate a palpable abnormality, 9/198 (<5%) to evaluate disease extent following neoadjuvant chemotherapy for a known breast malignancy, and 5/198 (<3%) for a 6-month follow-up. 97/104 (93%) women had dense breasts. Routine and implant-displaced low-energy views were obtained with contrast-enhanced images obtained on displaced views for all patients. 197/198 (99.5%) exams yielded no complications. In one exam, the patient experienced mild vasovagal symptoms following the administration of contrast. In conclusion, it is feasible to utilize CEM in both diagnostic and screening capacities in women with breast implants
Recommended from our members
Contamination artifact that mimics in-situ carcinoma on contrast-enhanced digital mammography.
PURPOSE: Contrast-enhanced digital mammography (CEDM) is an advanced breast imaging technique using iodinated intravenous contrast to detect breast cancer. This article describes imaging features of a skin contamination artifact on CEDM that mimics in-situ carcinoma in a case series. MATERIALS AND METHODS: Five patients were identified whose CEDM images demonstrated apparent calcifications and non-mass enhancement suspicious for in-situ carcinoma, with no subsequent evidence of disease. Retrospective image analysis was performed on the unprocessed image data, processed images, and imaging parameters. Dual-energy mammographic technique was performed on two breast phantoms with varying degrees of topical contrast contamination. RESULTS: Temporal analysis confirmed the suspicious finding was neither an abnormality of the compression paddle nor the receptor. Comparison of LE and HE images demonstrated the suspicious finding attenuated near the K-edge of iodine, suggesting contrast contamination. Iodinated contrast applied to the surface of breast phantoms replicated the artifact, with a pattern of apparent enhancement similar to the appearance of in-situ carcinoma. CONCLUSION: Skin contamination with iodinated contrast can result in an artifact on post-contrast digital mammography that mimics the appearance of in-situ carcinoma
Contrast-Enhanced Digital Mammography Screening for Intermediate-Risk Women With a History of Lobular Neoplasia.
OBJECTIVE. The objective of this study was to assess to the role of contrast-enhanced digital mammography (CEDM) as a screening tool in women at intermediate risk for developing breast cancer due to a personal history of lobular neoplasia without additional risk factors. MATERIALS AND METHODS. In this institutional review board-approved, observational, retrospective study, we reviewed our radiology department database to identify patients with a personal history of breast biopsy yielding lobular neoplasia who underwent screening CEDM at our institution between December 2012 and February 2019. A total of 132 women who underwent 306 CEDM examinations were included. All CEDM examinations were interpreted by dedicated breast imaging radiologists in conjunction with a review of the patients clinical history and available prior breast imaging. In statistical analysis, sensitivity, specificity, NPV, positive likelihood ratio, and accuracy of CEDM in detecting cancer were determined, with pathology or 12-month imaging follow-up serving as the reference standard. RESULTS. CEDM detected cancer in six patients and showed an overall sensitivity of 100%, specificity of 88% (95% CI, 84-92%), NPV of 100%, and accuracy of 88% (95% CI, 84-92%). The positive likelihood ratio of 8.33 suggested that CEDM findings are 8.3 times more likely to be positive in an individual with breast cancer when compared with an individual without the disease. CONCLUSION. CEDM shows promise as a breast cancer screening examination in patients with a personal history of lobular neoplasia. Continued investigation with a larger patient population is needed to determine the true sensitivity and positive predictive value of CEDM for these patients
Contrast-Enhanced Mammography and Radiomics Analysis for Noninvasive Breast Cancer Characterization: Initial Results.
PURPOSE: To investigate the potential of contrast-enhanced mammography (CEM) and radiomics analysis for the noninvasive differentiation of breast cancer invasiveness, hormone receptor status, and tumor grade. PROCEDURES: This retrospective study included 100 patients with 103 breast cancers who underwent pretreatment CEM. Radiomics analysis was performed using MAZDA software. Lesions were manually segmented. Radiomic features were derived from first-order histogram (HIS), co-occurrence matrix (COM), run length matrix (RLM), absolute gradient, autoregressive model, the discrete Haar wavelet transform (WAV), and lesion geometry. Fisher, probability of error and average correlation (POE+ACC), and mutual information (MI) coefficients informed feature selection. Linear discriminant analysis followed by k-nearest neighbor classification (with leave-one-out cross-validation) was used for pairwise texture-based separation of tumor invasiveness and hormone receptor status using histopathology as the standard of reference. RESULTS: Radiomics analysis achieved the highest accuracies of 87.4 % for differentiating invasive from noninvasive cancers based on COM+HIS/MI, 78.4 % for differentiating HR positive from HR negative cancers based on COM+HIS/Fisher, 97.2 % for differentiating human epidermal growth factor receptor 2 (HER2)-positive/HR-negative from HER2-negative/HR-positive cancers based on RLM+WAV/MI, 100 % for differentiating triple-negative from triple-positive breast cancers mainly based on COM+WAV+HIS/POE+ACC, and 82.1 % for differentiating triple-negative from HR-positive cancers mainly based on WAV+HIS/Fisher. Accuracies for differentiating grade 1 vs. grades 2 and 3 cancers were 90 % for invasive cancers (based on COM/MI) and 100 % for noninvasive cancers (almost entirely based on COM/MI). CONCLUSIONS: Radiomics analysis with CEM has potential for noninvasive differentiation of tumors with different degrees of invasiveness, hormone receptor status, and tumor grade
Utility of Targeted Ultrasound to Predict Malignancy Among Lesions Detected on Contrast-Enhanced Digital Mammography.
BACKGROUND. Targeted ultrasound (US) can be performed to characterize and potentially biopsy areas of enhancement detected on contrast-enhanced mammography (CEM). OBJECTIVE. The purpose of this study was to assess the utility of targeted US in predicting malignancy of lesions with indeterminate or suspicious enhancement on CEM. METHODS. One thousand consecutive CEM examinations with same-day targeted breast US at one institution between October 2013 and May 2018 were retrospectively reviewed. All patients with indeterminate or suspicious enhancement detected on CEM that underwent US evaluation were included. Patients with palpable or symptomatic lesions, those with suspicious findings on low-energy mammograms or images obtained with another modality, and those with less than 1 year of follow-up were excluded. Medical records, imaging, and pathology data were reviewed. Histopathologic analysis was used as the reference standard for biopsied lesions, and follow-up imaging was used for unbiopsied lesions. Associations between pathologic diagnosis, presence of a US correlate, and lesion characteristics were assessed by Fisher exact, chi-square, and Wilcox-on rank sum tests. RESULTS. Among 153 enhancing lesions detected on CEM in 144 patients, 47 (31%) had a US correlate. The frequency of a correlate between CEM and US was significantly higher among enhancing masses (28/43 [65%]) than among lesions exhibiting nonmass enhancement (19/110 [17%]) (p < .001). The likelihood of malignancy was significantly greater among lesions with a US correlate (12/47 [26%]) than among those without a US correlate (11/106 [10%]) (p = .03), and among mass lesions (11/43 [26%]) than among nonmass lesions (12/110 [11%]) (p = .04). The PPV of US-guided biopsy after CEM-directed US was 32%. CONCLUSION. Enhancing CEM-detected lesions that have a US correlate are more likely to be malignant and can be evaluated with US-guided biopsy to obviate additional breast MRI. CLINICAL IMPACT. CEM-directed US of enhancing lesions is useful given that lesions with a US correlate are more likely to be malignant and can be used as targets for US-guided biopsy until a CEM biopsy system becomes commercially available
Recommended from our members
Comparison of Background Parenchymal Enhancement at Contrast-enhanced Spectral Mammography and Breast MR Imaging.
Purpose To assess the extent of background parenchymal enhancement (BPE) at contrast material-enhanced (CE) spectral mammography and breast magnetic resonance (MR) imaging, to evaluate interreader agreement in BPE assessment, and to examine the relationships between clinical factors and BPE. Materials and Methods This was a retrospective, institutional review board-approved, HIPAA-compliant study. Two hundred seventy-eight women from 25 to 76 years of age with increased breast cancer risk who underwent CE spectral mammography and MR imaging for screening or staging from 2010 through 2014 were included. Three readers independently rated BPE on CE spectral mammographic and MR images with the ordinal scale: minimal, mild, moderate, or marked. To assess pairwise agreement between BPE levels on CE spectral mammographic and MR images and among readers, weighted κ coefficients with quadratic weights were calculated. For overall agreement, mean κ values and bootstrapped 95% confidence intervals were calculated. The univariate and multivariate associations between BPE and clinical factors were examined by using generalized estimating equations separately for CE spectral mammography and MR imaging. Results Most women had minimal or mild BPE at both CE spectral mammography (68%-76%) and MR imaging (69%-76%). Between CE spectral mammography and MR imaging, the intrareader agreement ranged from moderate to substantial (κ = 0.55-0.67). Overall agreement on BPE levels between CE spectral mammography and MR imaging and among readers was substantial (κ = 0.66; 95% confidence interval: 0.61, 0.70). With both modalities, BPE demonstrated significant association with menopausal status, prior breast radiation therapy, hormonal treatment, breast density on CE spectral mammographic images, and amount of fibroglandular tissue on MR images (P < .001 for all). Conclusion There was substantial agreement between readers for BPE detected on CE spectral mammographic and MR images. © RSNA, 2016
Recommended from our members
Non-Invasive Assessment of Breast Cancer Molecular Subtypes with Multiparametric Magnetic Resonance Imaging Radiomics.
We evaluated the performance of radiomics and artificial intelligence (AI) from multiparametric magnetic resonance imaging (MRI) for the assessment of breast cancer molecular subtypes. Ninety-one breast cancer patients who underwent 3T dynamic contrast-enhanced (DCE) MRI and diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) mapping were included retrospectively. Radiomic features were extracted from manually drawn regions of interest (n = 704 features per lesion) on initial DCE-MRI and ADC maps. The ten best features for subtype separation were selected using probability of error and average correlation coefficients. For pairwise comparisons with >20 patients in each group, a multi-layer perceptron feed-forward artificial neural network (MLP-ANN) was used (70% of cases for training, 30%, for validation, five times each). For all other separations, linear discriminant analysis (LDA) and leave-one-out cross-validation were applied. Histopathology served as the reference standard. MLP-ANN yielded an overall median area under the receiver-operating-characteristic curve (AUC) of 0.86 (0.77-0.92) for the separation of triple negative (TN) from other cancers. The separation of luminal A and TN cancers yielded an overall median AUC of 0.8 (0.75-0.83). Radiomics and AI from multiparametric MRI may aid in the non-invasive differentiation of TN and luminal A breast cancers from other subtypes
Recommended from our members
Radiomics for Tumor Characterization in Breast Cancer Patients: A Feasibility Study Comparing Contrast-Enhanced Mammography and Magnetic Resonance Imaging.
The aim of our intra-individual comparison study was to investigate and compare the potential of radiomics analysis of contrast-enhanced mammography (CEM) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) of the breast for the non-invasive assessment of tumor invasiveness, hormone receptor status, and tumor grade in patients with primary breast cancer. This retrospective study included 48 female patients with 49 biopsy-proven breast cancers who underwent pretreatment breast CEM and MRI. Radiomics analysis was performed by using MaZda software. Radiomics parameters were correlated with tumor histology (invasive vs. non-invasive), hormonal status (HR+ vs. HR-), and grading (low grade G1 + G2 vs. high grade G3). CEM radiomics analysis yielded classification accuracies of up to 92% for invasive vs. non-invasive breast cancers, 95.6% for HR+ vs. HR- breast cancers, and 77.8% for G1 + G2 vs. G3 invasive cancers. MRI radiomics analysis yielded classification accuracies of up to 90% for invasive vs. non-invasive breast cancers, 82.6% for HR+ vs. HR- breast cancers, and 77.8% for G1+G2 vs. G3 cancers. Preliminary results indicate a potential of both radiomics analysis of DCE-MRI and CEM for non-invasive assessment of tumor-invasiveness, hormone receptor status, and tumor grade. CEM may serve as an alternative to MRI if MRI is not available or contraindicated
- …