1,866 research outputs found

    The Effect of Patient's Asymmetric Information Problem on Medical Care Utilization with Consideration of a Patient's Ex-ante Health Status

    Get PDF
    Even if a patient's access to health information has been enhanced, a patient still doesn't have enough ability to utilize it. Therefore, a doctor's effort to sincerely communicate with a patient might affect the patient's use of medical care. This paper builds up the empirical model and found the effect of a doctor's effort on patient's medical care use was significant and according to the ex-ante health status of a patient, a doctor's effort influenced a patient's medical care use in different way.asymmetry of information between doctor and patient, patient's medical care use, doctor's effort to effectively communicate with patients, patient's ex-ante health status

    The uncalibrated pulse contour cardiac output during off-pump coronary bypass surgery: performance in patients with a low cardiac output status and a reduced left ventricular function

    Get PDF
    BACKGROUND: We compared the continuous cardiac index measured by the FloTrac/Vigileo™ system (FCI) to that measured by a pulmonary artery catheter (CCI) with emphasis on the accuracy of the FCI in patients with a decreased left ventricular ejection fraction (LVEF) and a low cardiac output status during off-pump coronary bypass surgery (OPCAB). We also assessed the influence of several factors affecting the pulse contour, such as the mean arterial pressure (MAP), the systemic vascular resistance index (SVRI) and the use of norepinephrine. METHODS: Fifty patients who were undergoing OPCAB (30 patients with a LVEF ≥ 40%, 20 patients with a LVEF < 40%) were enrolled. The FCI and CCI were measured and we performed a Bland-Altman analysis. Subgroup analyses were done according to the LVEF (< 40%), the CCI (≤ 2.4 L/min/m), the MAP (60-80 mmHg), the SVRI (1,600-2,600 dyne/s/cm(5)/m(2)) and the use of norepinephrine. RESULTS: The FCI was reliable at all the time points of measurement with an overall bias and limit of agreement of -0.07 and 0.67 L/min/m(2), respectively, resulting in a percentage error of 26.9%. The percentage errors in the patients with a decreased LVEF and in a low cardiac output status were 28.2% and 22.3%, respectively. However, the percentage error in the 91 data pairs outside the normal range of the SVRI was 40.2%. CONCLUSIONS: The cardiac output measured by the FloTrac/Vigileo™ system was reliable even in patients with a decreased LVEF and in a low cardiac output status during OPCAB. Acceptable agreement was also noted during the period of heart displacement and grafting of the obtuse marginalis branch.ope

    ??????????????? ????????? ????????? ?????? ??? ????????????

    Get PDF
    ??????????????? ????????? ???????????? ???????????? ?????? ?????????????????? ??????????????? ?????? ???????????? ??????. ??? ??????????????? ??????????????? ??? ?????? ????????? ???????????? ????????? ??????????????? ????????? ???????????????. ?????? ??????????????? ????????? ??? ?????? ????????? ???????????????, ??? ?????? ????????? diethylnitrosamine (DEN)??? C3H/HeN ?????? ?????? ?????? ???????????? ??? ?????? ????????? ????????? ???????????????. DEN?????? ????????? ???????????? ?????? alkaline phosphatase (ALP) ??????, TUNEL positive ???????????? ??????, ??? ???????????? ?????? ???????????? duct??? ??????, ?????????????????? ????????????, Masson???s trichrome ???????????? ????????? ???????????? ???, ?????? ?????? ?????? ??? ????????? ????????? ???????????? ?????? ???????????? ?????? ?????? ????????? ??? ?????????. ?????????, ??????????????? ?????? ???????????? ????????? ?????? ?????????????????? ??????, ?????? ?????? ??? ????????? ???????????? ??????????????? ???????????? ???????????? ???????????? ?????? ?????? ????????? ??? ?????????. ???????????? ???????????? ????????? ???????????? ??????, ???????????? ???????????? ???????????? ?????? ????????? ???, solvent partition ????????? ???????????? ????????? ???????????? hexane, ethyl acetate, water ???????????? ???????????????. ?????? ??????????????? ?????? ????????? ??????????????? ??????????????? ???, ethyl acetate ???????????? ??????????????? ????????? ?????????????????? ??????????????? ?????? ??????????????? ???????????? ????????? ????????? ????????? ??? ?????????. ????????? ethyl acetate???????????? ???????????? ????????? ????????? ??? ?????????, ??????????????? ????????? ??? ?????? ????????? ????????? ?????????. ???????????????, ??????????????? ????????? ????????????????????? ?????? ????????? ??? ?????? ????????? ???????????? ?????? ??????????????? ????????? ??? ?????? ????????? ????????? ????????? ?????? ???????????????. ?????????, ?????? ??????????????? ?????? ???????????? ?????? ??? ?????? ?????? ???????????? ??????????????? ?????? ????????? ????????? ??? ?????? ????????? ???????????? ??????.clos

    Electric field control of nonvolatile four-state magnetization at room temperature

    Get PDF
    We find the realization of large converse magnetoelectric (ME) effects at room temperature in a multiferroic hexaferrite Ba0.52_{0.52}Sr2.48_{2.48}Co2_{2}Fe24_{24}O41_{41} single crystal, in which rapid change of electric polarization in low magnetic fields (about 5 mT) is coined to a large ME susceptibility of 3200 ps/m. The modulation of magnetization then reaches up to 0.62 μ\muB_{B}/f.u. in an electric field of 1.14 MV/m. We find further that four ME states induced by different ME poling exhibit unique, nonvolatile magnetization versus electric field curves, which can be approximately described by an effective free energy with a distinct set of ME coefficients

    Initial adhesion of bone marrow stromal cells to various bone graft substitutes

    Get PDF
    Purpose: The aim of this study is to determine whether certain biomaterials have the potential to support cell attachment. After seeding bone marrow stromal cells onto the biomaterials, we investigated their responses to each material in vitro. Methods: Rat bone marrow derived stromal cells were used. The biomaterials were deproteinized bovine bone mineral (DBBM), DBBM coated with fibronectin (FN), synthetic hydroxyapatite (HA), HA coated with FN, HA coated with beta-tricalcium phosphate (TCP), and pure beta-TCP. With confocal laser scanning microscopy, actin filaments and vinculin were observed after 6, 12, and 24 hours of cell seeding. The morphological features of cells on each biomaterial were observed using scanning electron microscopy at day 1 and 7. Results: The cells on HA/FN and HA spread widely and showed better defined actin cytoskeletons than those on the other biomaterials. At the initial phase, FN seemed to have a favorable effect on cell adhesion. In DBBM, very few cells adhered to the surface. Conclusions: Within the limitations of this study, we can conclude that in contrast with DBBM not supporting cell attachment, HA provided a more favorable environment with respect to cell attachment. (C) 2011 Korean Academy of Periodontology.This work was supported by a National Research Foundation of Korea Grant funded by the Government of the Republic of Korea (2008-E00580)

    The dynamic development of germ cells during chicken embryogenesis

    Get PDF
    ArticlePoultry Science. 97(2): 650-657. (2018)journal articl
    corecore