1,601 research outputs found

    Nighttime administration of antihypertensive medication: a review of chronotherapy in hypertension

    Get PDF
    Hypertension remains a global health concern because of suboptimal blood pressure control despite advancements in antihypertensive treatments. Chronotherapy, defined as evening or bedtime administration of medication based on biological rhythms, is emerging as a potential strategy to improve blood pressure control and treatment outcomes. Clinical trials have investigated the potential effects of nighttime administration of antihypertensive medication in the improvement of 24 hours blood pressure control and reduction of cardiovascular risk. Implementing chronotherapy in clinical practice could have significant implications in enhancing blood pressure control and improving clinical outcomes in patients with hypertension, particularly those with resistant hypertension. However, recent trials have reported contradictory results, causing confusion in real-world practice. Herein we review, analyze, and critique the current evidence and propose suggestions regarding the clinical application and future directions of chronotherapy

    A highly sensitive and selective viral protein detection method based on RNA oligonucleotide nanoparticle

    Get PDF
    Globally, approximately 170 million people (representing approximately 3% of the population worldwide), are infected with hepatitis C virus (HCV) and at risk of serious liver disease, including chronic hepatitis. We propose a new quantum dots (QDs)-supported RNA oligonucleotide approach for the specific and sensitive detection of viral protein using a biochip. This method was developed by immobilizing a HCV nonstructural protein 5B (NS5B) on the surface of a glass chip via the formation of a covalent bond between an amine protein group and a ProLinker™ glass chip. The QDs-supported RNA oligonucleotide was conjugated via an amide formation reaction from coupling of a 5′-end-amine-modified RNA oligonucleotide on the surface of QDs displaying carboxyl groups via standard EDC coupling. The QDs-conjugated RNA oligonucleotide was interacted to immobilized viral protein NS5B on the biochip. The detection is based on the variation of signal of QDs-supported RNA oligonucleotide bound on an immobilized biochip. It was demonstrated that the value of the signal has a linear relationship with concentrations of the HCV NS5B viral protein in the 1 μg mL−1 to 1 ng mL−1 range with a detection limit of 1 ng mL−1. The major advantages of this RNA-oligonucleotide nanoparticle assay are its good specificity, ease of performance, and ability to perform one-spot monitoring. The proposed method could be used as a general method of HCV detection and is expected to be applicable to other types of diseases as well

    Application of PEEP using the i-gel during volume-controlled ventilation in anesthetized, paralyzed patients

    Get PDF
    PURPOSE: This prospective, randomized trial was designed to assess whether the i-gel supraglottic airway device is suitable for volume-controlled ventilation while applying positive end-expiratory pressure (PEEP) of 5 cmH(2)O under general anesthesia. It was believed that this device might improve arterial oxygenation. METHODS: Forty adult patients (aged 20–60 years) scheduled for elective orthopedic surgery were enrolled in this study. Twenty patients were ventilated without external PEEP [zero positive end-expiratory pressure (ZEEP) group], and the other 20 were ventilated with PEEP 5 cmH(2)O (PEEP group) after placing an i-gel device. Volume-controlled ventilation at a tidal volume (TV) of 8 ml/kg of ideal body weight, leak volume, and arterial blood gas analysis were investigated. RESULTS: The incidences of a significant leak were similar in the ZEEP and PEEP groups (3/20 and 1/20, respectively; P = 0.605), as were leak volumes. No significant PaO(2) difference was observed between the two groups at 1 h after satisfactory i-gel insertion (215 ± 38 vs. 222 ± 54; P = 0.502). CONCLUSIONS: The use of an i-gel during PEEP application at 5 cmH(2)O did not increase the incidence of a significant air leak, and a PEEP of 5 cmH(2)O failed to improve arterial oxygenation during controlled ventilation in healthy adult patients

    CT Scanning and Dental Implant

    Get PDF
    • …
    corecore