25 research outputs found
Chasing the thermodynamical noise limit in whispering-gallery-mode resonators for ultrastable laser frequency stabilization.
Ultrastable high-spectral-purity lasers have served as the cornerstone behind optical atomic clocks, quantum measurements, precision optical microwave generation, high-resolution optical spectroscopy, and sensing. Hertz-level lasers stabilized to high-finesse Fabry-Pérot cavities are typically used for these studies, which are large and fragile and remain laboratory instruments. There is a clear demand for rugged miniaturized lasers with stabilities comparable to those of bulk lasers. Over the past decade, ultrahigh-Q optical whispering-gallery-mode resonators have served as a platform for low-noise microlasers but have not yet reached the stabilities defined by their fundamental noise. Here, we show the noise characteristics of whispering-gallery-mode resonators and demonstrate a resonator-stabilized laser at this limit by compensating the intrinsic thermal expansion, allowing a sub-25 Hz linewidth and a 32 Hz Allan deviation. We also reveal the environmental sensitivities of the resonator at the thermodynamical noise limit and long-term frequency drifts governed by random-walk-noise statistics.High-quality optical resonators have the potential to provide a miniaturized frequency reference for metrology and sensing but they often lack stability. Here, Lim et al. experimentally characterize the stability of whispering-gallery resonators at their fundamental noise limits
Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world
Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic.
Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality.
Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States.
Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis.
Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection
All-fiber frequency comb employing a single walled carbon nanotube saturable absorber for optical frequency metrology in near infrared
Doctor of PhilosophyDepartment of PhysicsBrian R. WashburnOptical frequency combs produced by mode-locked fiber lasers are useful tools for high precision frequency metrology and molecular spectroscopy in a robust and portable format. We have specifically investigated erbium doped fiber mode-locked lasers that use single-walled carbon nanotubes as a saturable absorber. We have, for the first time, developed and phase- stabilized a carbon nanotube fiber laser (CNFL) frequency comb. The carbon nanotube saturable absorber, which was fabricated using an optically driven deposition method, permits a high repetition frequency (>150 MHz) since an optical nonlinearity of fibers is not used for mode-locking. The CNFL comb combined with a parabolic pulse erbium doped fiber amplifier (EDFA) has shown a compact, robust, and cost-effective supercontinuum source. The amplified pulse from the parabolic pulse EDFA was compressed with a hollow-core photonic bandgap fiber, which produced a wave-breaking-free pulse with an all-fiber set-up. The stabilized comb has demonstrated a fractional instability of 1.2 ×10[superscript]-11 at 1 sec averaging time, the reference-limited instability. We have performed optical frequency metrology with the CNFL comb and have measured an optical frequency, P(13) which is a molecular overtone transition of C2H2. The measured frequency has shown a good agreement with the known value within an uncertainty of 10 kHz.
In order to extend the application of the CNFL comb such as multi-heterodyne dual comb spectroscopy, we have investigated the noise of the CNFL comb and particularly, the broad carrier envelope offset frequency (f[subscript]0) linewidth of the CNFL comb. The primary noise source is shown to be white amplitude noise on the oscillator pump laser combined with the sensitivity of the mode-locked laser to pump power fluctuations. The control bandwidth of f[subscipt]0 was limited by the response dynamics of the CNFL comb. The significant reduction of comb noise has been observed by implementing a phase-lead compensation to extend control bandwidth of the comb and by reducing the pump relative intensity noise simultaneously. Therefore the f[subscipt]0 linewidth has been narrower from 850 kHz to 220 kHz. The integrated phase noise for the f[subscipt]0 lock is 1.6 radians from 100 Hz to 102 kHz
Stable frequency comb derived from a narrowband Yb-fiber laser: pre-chirp management for self-referenced stabilization
We demonstrate the feasibility of implementing frequency combs from a narrowband (5-nm, 415-fs transform-limited pulse) laser, paving the way for large line-spacing frequency combs based on multi-GHz lasers which emit long (>200 fs) pulses
BIM-based preliminary estimation method considering the life cycle cost for decision-making in the early design phase
Prediction of construction cost and life-cycle cost through preliminary estimate is very important for the economic decision-making in the early phase of building projects. However, the conventional preliminary estimate has a high error range and low reliability because it relies only on the basic information of projects. In addition, the consideration of the life-cycle cost of the building is insufficient, causing problems such as budget shortage, inaccurate budgeting, and life-cycle cost increase. In this study, we propose a method of preliminary estimate based on BIM below the level of detail 2 and actual construction cost data to support the decision-making in the early design phase. To verify the proposed method, a web-based prototype was implemented and applied to three test cases. The range of error rate for three test cases was 1.93–7.16% (average error rate: 5.18%). It satisfies the criteria (−30% ~ +50%) of the “American Association of Cost Engineering”. As a result, the feasibility of the proposed model was validated. It is expected to be utilized as useful information in the decision-making occurring in the early design phase, and this allows for a rapid economic review of the design alternatives, a reduced LCC, and a shortened decision-making time