1,911 research outputs found

    Inherent properties of binary tetrahedral semiconductors

    Full text link
    A new approach utilising the concept of ionic charge theory has been used to explain the inherent properties such as lattice thermal conductivity and bulk modulus of 3,5 and 2,6 semiconductors. The lattice thermal conductivity of these semiconductors exhibit a linear relationship when plotted on a log scale against the nearest neighbour distance but fall on two straight lines according to the product of the ionic charge of the compounds. On the basis of this result a simple relationship of lattice thermal conductivity with bulk modulus is proposed and used to estimate the bulk modulus of these semiconductors. A fairly good agreement has been found between the experimantal and calculated values of these parameters for zinc blende structured solids.Comment: 6 pages, 19 reference

    Role of advanced technology in the detection of sight-threatening eye disease in a UK community setting.

    Get PDF
    Background/aims: To determine the performance of combinations of structural and functional screening tests in detecting sight-threatening eye disease in a cohort of elderly subjects recruited from primary care. Methods: 505 subjects aged ≄60 years underwent frequency doubling technology (FDT) perimetry, iVue optical coherence tomography (iWellness and peripapillary retinal nerve fibre layer (RNFL) scans) and intraocular pressure with the Ocular Response Analyzer, all performed by an ophthalmic technician. The reference standard was a full ophthalmic examination by an experienced clinician who was masked to the index test results. Subjects were classified as presence or absence of sight-threatening eye disease (clinically significant cataract, primary open-angle glaucoma, intermediate or advanced age-related macular degeneration and significant diabetic retinopathy). Univariate and multivariate logistic regression analyses were used to determine the association between abnormal screening test results and the presence of sight-threatening eye disease. Results: 171 subjects (33.8%) had one or more sight-threatening eye diseases. The multivariate analysis found significant associations with any of the target conditions for visual acuity of <6/12, an abnormal FDT and peripapillary RNFL thickness outside the 99% normal limit. The sensitivity of this optimised screening panel was 61.3% (95% CI 53.5 to 68.7), with a specificity of 78.8% (95% CI 74.0 to 83.1), a positive predictive value of 59.5% (95% CI 53.7 to 65.2) and an overall diagnostic accuracy of 72.9% (95% CI 68.8 to 76.8). Conclusions: A subset of screening tests may provide an accurate and efficient means of population screening for significant eye disease in the elderly. This study provides useful preliminary data to inform the development of further larger, multicentre screening studies to validate this screening panel

    Multiple and Multidimensional life transitions in the context of life-limiting health conditions:Longitudinal study focussing on perspectives of Young Adults, Families and Professionals

    Get PDF
    Background: There is a dearth of literature that investigates life transitions of young adults (YAs) with life-limiting conditions, families and professionals. The scant literature that is available has methodological limitations, including not listening to the voice of YAs, collecting data retrospectively, at one time point, from one group’s perspective and single case studies. The aim of this study was to address the gaps found in our literature review and provide a clearer understanding of the multiple and multi-dimensional life transitions experienced by YAs and significant others, over a period of time. Methods: This qualitative study used a longitudinal design and data were collected using semi-structured interviews over a 6-month period at 3 time points. Participants included 12 YAs with life-limiting conditions and their nominated significant others (10 family members and 11 professionals). Data were analysed using a thematic analysis approach. Results: Life transitions of YA and significant others are complex; they experience multiple and multi-dimensional transitions across several domains. The findings challenge the notion that all life transitions are triggered by health transitions of YAs, and has highlighted environmental factors (attitudinal and systemic) that can be changed to facilitate smoother transitions in various aspects of their lives. Conclusions: This study makes a unique and significant contribution to literature. It provides evidence and rich narratives for policy makers and service providers to change policies and practices that are in line with the needs of YAs with life-limiting conditions as they transition to adulthood. Families and professionals have specific training needs that have not yet been met fully

    Assessment of Global Kidney Health Care Status.

    Full text link
    Kidney disease is a substantial worldwide clinical and public health problem, but information about available care is limited.To collect information on the current state of readiness, capacity, and competence for the delivery of kidney care across countries and regions of the world.Questionnaire survey administered from May to September 2016 by the International Society of Nephrology (ISN) to 130 ISN-affiliated countries with sampling of key stakeholders (national nephrology society leadership, policy makers, and patient organization representatives) identified by the country and regional nephrology leadership through the ISN.Core areas of country capacity and response for kidney care.Responses were received from 125 of 130 countries (96%), including 289 of 337 individuals (85.8%, with a median of 2 respondents [interquartile range, 1-3]), representing an estimated 93% (6.8 billion) of the world's population of 7.3 billion. There was wide variation in country readiness, capacity, and response in terms of service delivery, financing, workforce, information systems, and leadership and governance. Overall, 119 (95%), 95 (76%), and 94 (75%) countries had facilities for hemodialysis, peritoneal dialysis, and kidney transplantation, respectively. In contrast, 33 (94%), 16 (45%), and 12 (34%) countries in Africa had facilities for hemodialysis, peritoneal dialysis, and kidney transplantation, respectively. For chronic kidney disease (CKD) monitoring in primary care, serum creatinine with estimated glomerular filtration rate and proteinuria measurements were reported as always available in only 21 (18%) and 9 (8%) countries, respectively. Hemodialysis, peritoneal dialysis, and transplantation services were funded publicly and free at the point of care delivery in 50 (42%), 48 (51%), and 46 (49%) countries, respectively. The number of nephrologists was variable and was low (<10 per million population) in Africa, the Middle East, South Asia, and Oceania and South East Asia (OSEA) regions. Health information system (renal registry) availability was limited, particularly for acute kidney injury (8 countries [7%]) and nondialysis CKD (9 countries [8%]). International acute kidney injury and CKD guidelines were reportedly accessible in 52 (45%) and 62 (52%) countries, respectively. There was relatively low capacity for clinical studies in developing nations.This survey demonstrated significant interregional and intraregional variability in the current capacity for kidney care across the world, including important gaps in services and workforce. Assuming the responses accurately reflect the status of kidney care in the respondent countries, the findings may be useful to inform efforts to improve the quality of kidney care worldwide

    A perceptual model of motion quality for rendering with adaptive refresh-rate and resolution

    Get PDF
    Limited GPU performance budgets and transmission bandwidths mean that real-time rendering often has to compromise on the spatial resolution or temporal resolution (refresh rate). A common practice is to keep either the resolution or the refresh rate constant and dynamically control the other variable. But this strategy is non-optimal when the velocity of displayed content varies. To find the best trade-off between the spatial resolution and refresh rate, we propose a perceptual visual model that predicts the quality of motion given an object velocity and predictability of motion. The model considers two motion artifacts to establish an overall quality score: non-smooth (juddery) motion, and blur. Blur is modeled as a combined effect of eye motion, finite refresh rate and display resolution. To fit the free parameters of the proposed visual model, we measured eye movement for predictable and unpredictable motion, and conducted psychophysical experiments to measure the quality of motion from 50 Hz to 165 Hz. We demonstrate the utility of the model with our on-the-fly motion-adaptive rendering algorithm that adjusts the refresh rate of a G-Sync-capable monitor based on a given rendering budget and observed object motion. Our psychophysical validation experiments demonstrate that the proposed algorithm performs better than constant-refresh-rate solutions, showing that motion-adaptive rendering is an attractive technique for driving variable-refresh-rate displays.</jats:p

    Predictive value of screening tests for sight-threatening eye disease in a UK population

    Get PDF
    Background/Aims To determine the performance of combinations of structural and functional screening tests in detecting sight-threatening eye disease in a cohort of elderly subjects recruited from primary care Methods 505 subjects ≄ 60 years underwent: Frequency Doubling Technology (FDT) perimetry; iVue OCT (iWellnessÂź and peripapillary retinal nerve fibre layer (RNFL) scans); IOP with the Ocular Response Analyzer (ORA), all performed by an ophthalmic technician. The reference standard was a full ophthalmic examination by an experienced clinician who was masked to the index test results. Subjects were classified as presence or absence of sight-threatening eye disease (clinically significant cataract, primary open angle glaucoma, intermediate or advanced AMD and significant diabetic retinopathy). Univariate and multivariate logistic regression was used to determine the association between abnormal screening test results and the presence of sight-threatening eye disease. Results 171 subjects (33.8%) had one or more sight-threatening eye disease(s). The multivariate analysis found significant associations with any of the target conditions for visual acuity < 6/12, an abnormal FDT and peripapillary RNFL thickness outside the 99% normal limit. The sensitivity of this optimised screening panel was 61.3% (95% CI 53.5-68.7); specificity 78.8% (CI 74.0-83.1), positive predictive value 59.5% (CI 53.7-65.2) and an overall diagnostic accuracy of 72.9% (CI 68.8-76.8). Conclusion A subset of screening tests may provide an accurate and efficient means of population screening for significant eye disease in the elderly. This study provides useful preliminary data to inform the development of further larger, multicentre screening studies to validate this screening panel

    Use of polyethylene glycol coatings for optical fibre humidity sensing

    Get PDF
    Humidity induced change in the refractive index and thickness of the polyethylene glycol (PEG) coatings are in situ investigated for a range from 10 to 95%, using an optical waveguide spectroscopic technique. It is experimentally demonstrated that, upon humidity change, the optical and swelling characteristics of the PEG coatings can be employed to build a plastic fibre optic humidity sensor. The sensing mechanism is based on the humidity induced change in the refractive index of the PEG film, which is directly coated onto a polished segment of a plastic optical fibre with dip-coating method. It is observed that PEG, which is a highly hydrophilic material, shows no monotonic linear response to humidity but gives different characteristics for various ranges of humidity levels both in index of refraction and in thickness. It undergoes a physical phase change from a semi-crystal line structure to a gel one at around 80% relative humidity. At this phase change point, a drastic decrease occurs in the index of refraction as well as a drastic increase in the swelling of the PEG film. In addition, PEG coatings are hydrogenated in a vacuum chamber. It is observed that the hydrogen has a preventing effect on the humidity induced phase change in PEG coatings. Finally, the possibility of using PEG coatings in construction of a real plastic fibre optic humidity sensor is discussed. (C) 2008 The Optical Society of Japan
    • 

    corecore