10 research outputs found
2 x 2 Polyethylene Reflected and Moderated Highly Enriched Uranium System with Rhenium
The 2 × 2 array HEU-Re experiment was performed on the Planet universal critical assembly machine on November 4th, 2003 at the Los Alamos Critical Experiments Facility (LACEF) at Los Alamos National Laboratory (LANL). For this experiment, there were 10 ½ units, each full unit containing four HEU foils and two rhenium foils. The top unit contained only two HEU foils and two rhenium foils. A total of 42 HEU foils were used for this experiment. Rhenium is a desirable cladding material for space nuclear power applications. This experiment consisted of HEU foils interleaved with rhenium foils and is moderated and reflected by polyethylene plates. A unit consisted of a polyethylene plate, which has a recess for rhenium foils, and four HEU foils in a single layer in the top recess of each polyethylene plate. The Planet universal criticality assembly machine has been previously used in experiments containing HEU foils interspersed with SiO2 (HEU-MET-THERM-001), Al (HEU-MET-THERM-008), MgO (HEU-MET-THERM-009), Gd foils (HEU-MET-THERM-010), 2 × 2 × 26 Al (HEU-MET-THERM-012), Fe (HEU-MET-THERM-013 and HEU-MET-THERM-015), 2 × 2 × 23 SiO2 (HEU-MET-THERM-014), 2 × 2 × 11 hastalloy plates (HEU-MET-THERM-016), and concrete (HEU-MET-THERM-018). The 2 × 2 array of HEU-Re is considered acceptable for use as a benchmark critical experiment
Recommended from our members
2 x 2 Polyethylene Reflected and Moderated Highly Enriched Uranium System with Rhenium
The 2 × 2 array HEU-Re experiment was performed on the Planet universal critical assembly machine on November 4th, 2003 at the Los Alamos Critical Experiments Facility (LACEF) at Los Alamos National Laboratory (LANL). For this experiment, there were 10 ½ units, each full unit containing four HEU foils and two rhenium foils. The top unit contained only two HEU foils and two rhenium foils. A total of 42 HEU foils were used for this experiment. Rhenium is a desirable cladding material for space nuclear power applications. This experiment consisted of HEU foils interleaved with rhenium foils and is moderated and reflected by polyethylene plates. A unit consisted of a polyethylene plate, which has a recess for rhenium foils, and four HEU foils in a single layer in the top recess of each polyethylene plate. The Planet universal criticality assembly machine has been previously used in experiments containing HEU foils interspersed with SiO2 (HEU-MET-THERM-001), Al (HEU-MET-THERM-008), MgO (HEU-MET-THERM-009), Gd foils (HEU-MET-THERM-010), 2 × 2 × 26 Al (HEU-MET-THERM-012), Fe (HEU-MET-THERM-013 and HEU-MET-THERM-015), 2 × 2 × 23 SiO2 (HEU-MET-THERM-014), 2 × 2 × 11 hastalloy plates (HEU-MET-THERM-016), and concrete (HEU-MET-THERM-018). The 2 × 2 array of HEU-Re is considered acceptable for use as a benchmark critical experiment
The National Criticality Experiments Research Center and its role in support of advanced reactor design
The National Criticality Experiments Research Center (NCERC) located at the Nevada National Security Site (NNSS) in the Device Assembly Facility (DAF) and operated by Los Alamos National Laboratory (LANL) is the only general purpose critical experiments facility in the United States. Experiments from subcritical to critical and above prompt critical are carried out at NCERC on a regular basis. In recent years, NCERC has become more involved in experiments related to nuclear energy, including the Kilopower/KRUSTY demonstration and the recent Hypatia experiment. Multiple nuclear energy related projects are currently ongoing at NCERC. This paper discusses NCERC’s role in advanced reactor design and how that role may change in the future
Recommended from our members
Benchmark Analysis of Subcritical Noise Measurements on a Nickel-Reflected Plutonium Metal Sphere
Subcritical experiments using californium source-driven noise analysis (CSDNA) and Feynman variance-to-mean methods were performed with an alpha-phase plutonium sphere reflected by nickel shells, up to a maximum thickness of 7.62 cm. Both methods provide means of determining the subcritical multiplication of a system containing nuclear material. A benchmark analysis of the experiments was performed for inclusion in the 2010 edition of the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Benchmark models have been developed that represent these subcritical experiments. An analysis of the computed eigenvalues and the uncertainty in the experiment and methods was performed. The eigenvalues computed using the CSDNA method were very close to those calculated using MCNP5; however, computed eigenvalues are used in the analysis of the CSDNA method. Independent calculations using KENO-VI provided similar eigenvalues to those determined using the CSDNA method and MCNP5. A slight trend with increasing nickel-reflector thickness was seen when comparing MCNP5 and KENO-VI results. For the 1.27-cm-thick configuration the MCNP eigenvalue was approximately 300 pcm greater. The calculated KENO eigenvalue was about 300 pcm greater for the 7.62-cm-thick configuration. The calculated results were approximately the same for a 5-cm-thick shell. The eigenvalues determined using the Feynman method are up to approximately 2.5% lower than those determined using either the CSDNA method or the Monte Carlo codes. The uncertainty in the results from either method was not large enough to account for the bias between the two experimental methods. An ongoing investigation is being performed to assess what potential uncertainties and/or biases exist that have yet to be properly accounted for. The dominant uncertainty in the CSDNA analysis was the uncertainty in selecting a neutron cross-section library for performing the analysis of the data. The uncertainty in the Feynman method was equally shared between the uncertainties in fitting the data to the Feynman equations and the neutron multiplicity of 239Pu. Material and geometry uncertainties in the benchmark experiment were generally much smaller than uncertainties in the analysis methods
Gait speed, cognition and falls in people living with mild-to-moderate Alzheimer disease: Data from NILVAD
Background: Previous evidence suggests that slower gait speed is longitudinally associated with cognitive impairment, dementia and falls in older adults. Despite this, the longitudinal relationship between gait speed, cognition and falls in those with a diagnosis of dementia remains poorly explored. We sought to assess this longitudinal relationship in a cohort of older adults with mild to-moderate Alzheimer Disease (AD). Methods: Analysis of data from NILVAD, an 18-month randomised-controlled trial of Nilvadipine in mild to moderate AD. We examined: (i) the cross-sectional (baseline) association between slow gait speed and cognitive function, (ii) the relationship between baseline slow gait speed and cognitive function at 18 months (Alzheimer Disease Assessment Scale, Cognitive Subsection: ADAS-Cog), (iii) the relationship between baseline cognitive function and incident slow gait speed at 18 months and finally (iv) the relationship of baseline slow gait speed and incident falls over the study period. Results: Overall, one-tenth (10.03%, N = 37/369) of participants with mild-to-moderate AD met criteria for slow gait speed at baseline and a further 14.09% (N = 52/369) developed incident slow gait speed at 18 months. At baseline, there was a significant association between poorer cognition and slow gait speed (OR 1.05, 95% CI 1.01-1.09, p = 0.025). Whilst there was no association between baseline slow gait speed and change in ADAS-Cog score at 18 months, a greater cognitive severity at baseline predicted incident slow gait speed over 18 months (OR 1.04, 1.01-1.08, p = 0.011). Further, slow gait speed at baseline was associated with a significant risk of incident falls over the study period, which persisted after covariate adjustment (IRR 3.48, 2.05-5.92, p < 0.001). Conclusions: Poorer baseline cognition was associated with both baseline and incident slow gait speed. Slow gait speed was associated with a significantly increased risk of falls over the study period. Our study adds further evidence to the complex relationship between gait and cognition in this vulnerable group and highlights increased falls risk in older adults with AD and slow gait speed. Trial registration: Secondary analysis of the NILVAD trial (Clincaltrials.gov NCT02017340; EudraCT number 2012-002764-27). First registered: 20/12/2013