Electrocardiographic indicators of acute coronary syndrome are more common in patients with ambulance transport compared to those who self-transport to the emergency department journal of electrocardiology
The American Heart Association recommends individuals with symptoms suggestive of acute coronary syndrome (ACS) activate the Emergency Medical Services’ (EMS) 911 system for ambulance transport to the emergency department (ED), which enables treatment to begin prior to hospital arrival. Despite this recommendation, the majority of patients with symptoms suspicious of ACS continue to self-transport to the ED. The IMMEDIATE AIM study was a prospective study that enrolled individuals who presented to the ED with ischemic symptoms
Cardiac Monitoring in the Emergency Department
Patients present to the emergency department (ED) with a wide range of complaints and ED clinicians are responsible for identifying which conditions are life threatening. Cardiac monitoring strategies in the ED include, but are not limited to, 12-lead electrocardiography and bedside cardiac monitoring for arrhythmia and ischemia detection as well as QT-interval monitoring. ED nurses are in a unique position to incorporate cardiac monitoring into the early triage and risk stratification of patients with cardiovascular emergencies to optimize patient management and outcomes
Patient Characteristics Associated with False Arrhythmia Alarms in Intensive Care
Introduction
A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms.
Objective
The aim of this study was to identify patient characteristics, such as gender, age, body mass index, and diagnosis associated with frequent false arrhythmia alarms in the ICU.
Methods
This descriptive, observational study prospectively enrolled patients who were consecutively admitted to one of five adult ICUs (77 beds) at an urban medical center over a period of 31 days in 2013. All monitor alarms and continuous waveforms were stored on a secure server. Nurse scientists with expertise in cardiac monitoring used a standardized protocol to annotate six clinically important types of arrhythmia alarms (asystole, pause, ventricular fibrillation, ventricular tachycardia, accelerated ventricular rhythm, and ventricular bradycardia) as true or false. Total monitoring time for each patient was measured, and the number of false alarms per hour was calculated for these six alarm types. Medical records were examined to acquire data on patient characteristics.
Results
A total of 461 unique patients (mean age =60±17 years) were enrolled, generating a total of 2,558,760 alarms, including all levels of arrhythmia, parameter, and technical alarms. There were 48,404 hours of patient monitoring time, and an average overall alarm rate of 52 alarms/hour. Investigators annotated 12,671 arrhythmia alarms; 11,345 (89.5%) were determined to be false. Two hundred and fifty patients (54%) generated at least one of the six annotated alarm types. Two patients generated 6,940 arrhythmia alarms (55%). The number of false alarms per monitored hour for patients’ annotated arrhythmia alarms ranged from 0.0 to 7.7, and the duration of these false alarms per hour ranged from 0.0 to 158.8 seconds. Patient characteristics were compared in relation to 1) the number and 2) the duration of false arrhythmia alarms per 24-hour period, using nonparametric statistics to minimize the influence of outliers. Among the significant associations were the following: age ≥60 years (P=0.013; P=0.034), confused mental status (P\u3c0.001 for both comparisons), cardiovascular diagnoses (P\u3c0.001 for both comparisons), electrocardiographic (ECG) features, such as wide ECG waveforms that correspond to ventricular depolarization known as QRS complex due to bundle branch block (BBB) (P=0.003; P=0.004) or ventricular paced rhythm (P=0.002 for both comparisons), respiratory diagnoses (P=0.004 for both comparisons), and support with mechanical ventilation, including those with primary diagnoses other than respiratory ones (P\u3c0.001 for both comparisons).
Conclusion
Patients likely to trigger a higher number of false arrhythmia alarms may be those with older age, confusion, cardiovascular diagnoses, and ECG features that indicate BBB or ventricular pacing, respiratory diagnoses, and mechanical ventilatory support. Algorithm improvements could focus on better noise reduction (eg, motion artifact with confused state) and distinguishing BBB and paced rhythms from ventricular arrhythmias. Increasing awareness of patient conditions that apparently trigger a higher rate of false arrhythmia alarms may be useful for reducing unnecessary noise and improving alarm management
Impact of Using Drones in Emergency Medicine: What Does the Future Hold?
The use of unmanned aerial vehicles or drones has expanded in the last decade, as their technology has become more sophisticated, and costs have decreased. They are now used routinely in farming, environmental surveillance, public safety, commercial product delivery, recreation, and other applications. Health-related applications are only recently becoming more widely explored and accepted. The use of drone technology in emergency medicine is especially promising given the need for a rapid response to enhance patient outcomes. The purpose of this paper is to describe some of the main current and expanding applications of drone technology in emergency medicine and to describe challenges and future opportunities. Current applications being studied include delivery of defibrillators in response to out-of-hospital cardiac arrest, blood and blood products in response to trauma, and rescue medications. Drones are also being studied and actively used in emergency response to search and rescue operations as well as disaster and mass casualty events. Current challenges to expanding their use in emergency medicine and emergency medical system (EMS) include regulation, safety, flying conditions, concerns about privacy, consent, and confidentiality, and details surrounding the development, operation, and maintenance of a medical drone network. Future research is needed to better understand end user perceptions and acceptance. Continued technical advances are needed to increase payload capacities, increase flying distances, and integrate drone networks into existing 9-1-1 and EMS systems. Drones are a promising technology for improving patient survival, outcomes, and quality of life, particularly for those in areas that are remote or that lack funds or infrastructure. Their cost savings compared with ground transportation alone, speed, and convenience make them particularly applicable in the field of emergency medicine. Research to date suggests that use of drones in emergency medicine is feasible, will be accepted by the public, is cost-effective, and has broad application
Patient characteristics associated with false arrhythmia alarms in intensive care
A high rate of false arrhythmia alarms in the intensive care unit (ICU) leads to alarm fatigue, the condition of desensitization and potentially inappropriate silencing of alarms due to frequent invalid and nonactionable alarms, often referred to as false alarms
Normal prehospital electrocardiography is linked to long-term survival in patients presenting to the emergency department with symptoms of acute coronary syndrome
We studied 735 patients who activated “911” for chest pain and/or anginal equivalent symptoms and received 12-lead ECG monitoring with specialized ischemia monitoring software in the ambulance. Prehospital electrocardiograms (PH ECG) were analyzed to determine the proportion of patients who present with completely normal PH ECG findings (absence of ischemia/infarction, arrhythmia, or any other abnormality) and to compare outcomes amongst patients with and without any PH ECG abnormality
- …