    Misplaced Cervical Screws Requiring Reoperation.

    Get PDF
    STUDY DESIGN: A multicenter, retrospective case series. OBJECTIVE: In the past several years, screw fixation of the cervical spine has become commonplace. For the most part, this is a safe, low-risk procedure. While rare, screw backout or misplaced screws can lead to morbidity and increased costs. We report our experiences with this uncommon complication. METHODS: A multicenter, retrospective case series was undertaken at 23 institutions in the United States. Patients were included who underwent cervical spine surgery from January 1, 2005, to December 31, 2011, and had misplacement of screws requiring reoperation. Institutional review board approval was obtained at all participating institutions, and detailed records were sent to a central data center. RESULTS: A total of 12 903 patients met the inclusion criteria and were analyzed. There were 11 instances of screw backout requiring reoperation, for an incidence of 0.085%. There were 7 posterior procedures. Importantly, there were no changes in the health-related quality-of-life metrics due to this complication. There were no new neurologic deficits; a patient most often presented with pain, and misplacement was diagnosed on plain X-ray or computed tomography scan. The most common location for screw backout was C6 (36%). CONCLUSIONS: This study represents the largest series to tabulate the incidence of misplacement of screws following cervical spine surgery, which led to revision procedures. The data suggest this is a rare event, despite the widespread use of cervical fixation. Patients suffering this complication can require revision, but do not usually suffer neurologic sequelae. These patients have increased cost of care. Meticulous technique and thorough knowledge of the relevant anatomy are the best means of preventing this complication

    Incidence and Outcomes of Acute Implant Extrusion Following Anterior Cervical Spine Surgery.

    Get PDF
    STUDY DESIGN: Multi-institutional retrospective case series of 8887 patients who underwent anterior cervical spine surgery. OBJECTIVE: Anterior decompression from discectomy or corpectomy is not without risk. Surgical morbidity ranges from 9% to 20% and is likely underreported. Little is known of the incidence and effects of rare complications on functional outcomes following anterior spinal surgery. In this retrospective review, we examined implant extrusions (IEs) following anterior cervical fusion. METHODS: A retrospective multicenter case series study involving 21 high-volume surgical centers from the AOSpine North America Clinical Research Network. Medical records for 17 625 patients who received cervical spine surgery (levels from C2 to C7) between January 1, 2005, and December 31, 2011, were reviewed to identify occurrence of 21 predefined treatment complications. RESULTS: Following anterior cervical fusion, the incidence of IE ranged from 0.0% to 0.8% across 21 institutions with 11 cases reported. All surgeries involved multiple levels, and 7/11 (64%) involved either multilevel corpectomies or hybrid constructs with at least one adjacent discectomy to a corpectomy. In 7/11 (64%) patients, constructs ended with reconstruction or stabilization at C7. Nine patients required surgery for repair and stabilization following IE. Average length of hospital stay after IE was 5.2 days. Only 2 (18%) had residual deficits after reoperation. CONCLUSIONS: IE is a very rare complication after anterior cervical spine surgery often requiring revision. Constructs requiring multilevel reconstruction, especially at the cervicothoracic junction, have a higher risk for failure, and surgeons should proceed with caution in using an anterior-only approach in these demanding cases. Surgeons can expect most patients to regain function after reoperation

    Refractory Intracranial Hypertension due to Fentanyl Administration Following Closed Head Injury

    Get PDF
    BackgroundAlthough the effects of opioids on intracranial pressure have long been a subject of controversy, they are frequently administered to patients with severe head trauma. We present a patient with an uncommon paradoxical response to opioids.Case ReportA patient with refractory intracranial hypertension after closed head injury was managed with standard medical therapy with only transient decreases in the intracranial pressure. Only after discontinuation of opiates did the intracranial pressure become manageable without metabolic suppression and rescue osmotic therapy, implicating opiates as the etiology of refractory intracranial hypertension in this patient. ConclusionsClinicians should consider opioids as a contributing factor in malignant intracranial hypertension when findings on neuroimaging do not explain persistent and refractory intracranial hypertension

    Elevated hematocrit enhances platelet accumulation following vascular injury

    No full text
    Red blood cells (RBCs) demonstrate procoagulant properties in vitro, and elevated hematocrit is associated with reduced bleeding and increased thrombosis risk in humans. These observations suggest RBCs contribute to thrombus formation. However, effects of RBCs on thrombosis are difficult to assess because humans and mice with elevated hematocrit typically have coexisting pathologies. Using an experimental model of elevated hematocrit in healthy mice, we measured effects of hematocrit in 2 in vivo clot formation models. We also assessed thrombin generation, platelet-thrombus interactions, and platelet accumulation in thrombi ex vivo, in vitro, and in silico. Compared with controls, mice with elevated hematocrit (RBCHIGH) formed thrombi at a faster rate and had a shortened vessel occlusion time. Thrombi in control and RBCHIGH mice did not differ in size or fibrin content, and there was no difference in levels of circulating thrombin-antithrombin complexes. In vitro, increasing the hematocrit increased thrombin generation in the absence of platelets; however, this effect was reduced in the presence of platelets. In silico, direct numerical simulations of whole blood predicted elevated hematocrit increases the frequency and duration of interactions between platelets and a thrombus.Whenhumanwhole blood was perfused over collagen at arterial shear rates, elevating the hematocrit increased the rate of platelet deposition and thrombus growth. These data suggest RBCs promote arterial thrombosis by enhancing platelet accumulation at the site of vessel injury. Maintaining a normal hematocrit may reduce arterial thrombosis risk in humans

    Catastrophic acute failure of pelvic fixation in adult spinal deformity requiring revision surgery: a multicenter review of incidence, failure mechanisms, and risk factors

    No full text
    OBJECTIVE: There are few prior reports of acute pelvic instrumentation failure in spinal deformity surgery. The objective of this study was to determine if a previously identified mechanism and rate of pelvic fixation failure were present across multiple institutions, and to determine risk factors for these types of failures. METHODS: Thirteen academic medical centers performed a retrospective review of 18 months of consecutive adult spinal fusions extending 3 or more levels, which included new pelvic screws at the time of surgery. Acute pelvic fixation failure was defined as occurring within 6 months of the index surgery and requiring surgical revision. RESULTS: Failure occurred in 37 (5%) of 779 cases and consisted of either slippage of the rods or displacement of the set screws from the screw tulip head (17 cases), screw shaft fracture (9 cases), screw loosening (9 cases), and/or resultant kyphotic fracture of the sacrum (6 cases). Revision strategies involved new pelvic fixation and/or multiple rod constructs. Six patients (16%) who underwent revision with fewer than 4 rods to the pelvis sustained a second acute failure, but no secondary failures occurred when at least 4 rods were used. In the univariate analysis, the magnitude of surgical correction was higher in the failure cohort (higher preoperative T1-pelvic angle [T1PA], presence of a 3-column osteotomy; p \u3c 0.05). Uncorrected postoperative deformity increased failure risk (pelvic incidence-lumbar lordosis mismatch \u3e 10°, higher postoperative T1PA; p \u3c 0.05). Use of pelvic screws less than 8.5 mm in diameter also increased the likelihood of failure (p \u3c 0.05). In the multivariate analysis, a larger preoperative global deformity as measured by T1PA was associated with failure, male patients were more likely to experience failure than female patients, and there was a strong association with implant manufacturer (p \u3c 0.05). Anterior column support with an L5-S1 interbody fusion was protective against failure (p \u3c 0.05). CONCLUSIONS: Acute catastrophic failures involved large-magnitude surgical corrections and likely resulted from high mechanical strain on the pelvic instrumentation. Patients with large corrections may benefit from anterior structural support placed at the most caudal motion segment and multiple rods connecting to more than 2 pelvic fixation points. If failure occurs, salvage with a minimum of 4 rods and 4 pelvic fixation points can be successful