1,278 research outputs found
Fast path and polarisation manipulation of telecom wavelength single photons in lithium niobate waveguide devices
We demonstrate fast polarisation and path control of photons at 1550 nm in
lithium niobate waveguide devices using the electro-optic effect. We show
heralded single photon state engineering, quantum interference, fast state
preparation of two entangled photons and feedback control of quantum
interference. These results point the way to a single platform that will enable
the integration of nonlinear single photon sources and fast reconfigurable
circuits for future photonic quantum information science and technology.Comment: 6 page
Fabrication on the microscale : a two-photon polymerized device for oocyte microinjection
Open Access funding enabled and organized by CAUL and its Member Institutions. KRD is supported by a Mid-Career Fellowship from the Hospital Research Foundation (C-MCF-58–2019). KD acknowledges funding from the UK Engineering and Physical Sciences Research Council (grant EP/P030017/1). This study was funded by the Australian Research Council (ARC) Centre of Excellence for Nanoscale BioPhotonics (CE140100003).Purpose Intracytoplasmic sperm injection (ICSI) addresses male sub-fertility by injecting a spermatozoon into the oocyte. This challenging procedure requires the use of dual micromanipulators, with success influenced by inter-operator expertise. We hypothesized that minimizing oocyte handling during ICSI will simplify the procedure. To address this, we designed and fabricated a micrometer scale device that houses the oocyte and requires only one micromanipulator for microinjection. Methods The device consisted of 2 components, each of sub-cubic millimeter volume: a Pod and a Garage. These were fabricated using 2-photon polymerization. Toxicity was evaluated by culturing single-mouse presumptive zygotes (PZs) to the blastocyst stage within a Pod, with several Pods (and embryos) docked in a Garage. The development was compared to standard culture. The level of DNA damage/repair in resultant blastocysts was quantified (γH2A.X immunohistochemistry). To demonstrate the capability to carry out ICSI within the device, PZs were microinjected with 4-μm fluorescent microspheres and cultured to the blastocyst stage. Finally, the device was assessed for oocyte traceability and high-throughput microinjection capabilities and compared to standard microinjection practice using key parameters (pipette setup, holding then injecting oocytes). Results Compared to standard culture, embryo culture within Pods and a Garage showed no differences in development to the blastocyst stage or levels of DNA damage in resultant blastocysts. Furthermore, microinjection within our device removes the need for a holding pipette, improves traceability, and facilitates high-throughput microinjection. Conclusion This novel device could improve embryo production following ICSI by simplifying the procedure and thus decreasing inter-operator variability.Publisher PDFPeer reviewe
Pseudo-label refinement using superpixels for semi-supervised brain tumour segmentation
Training neural networks using limited annotations is an important problem in the medical domain. Deep Neural Networks (DNNs) typically require large, annotated datasets to achieve acceptable performance which, in the medical domain, are especially difficult to obtain as they require significant time from expert radiologists. Semi-supervised learning aims to overcome this problem by learning segmentations with very little annotated data, whilst exploiting large amounts of unlabelled data. However, the best-known technique, which utilises inferred pseudo-labels, is vulnerable to inaccurate pseudo-labels degrading the performance. We propose a framework based on superpixels - meaningful clusters of adjacent pixels - to improve the accuracy of the pseudo labels and address this issue. Our framework combines superpixels with semi-supervised learning, refining the pseudo-labels during training using the features and edges of the superpixel maps. This method is evaluated on a multimodal magnetic resonance imaging (MRI) dataset for the task of brain tumour region segmentation. Our method demonstrates improved performance over the standard semi-supervised pseudo-labelling baseline when there is a reduced annotator burden and only 5 annotated patients are available. We report DSC=0.824 and DSC=0.707 for the test set whole tumour and tumour core regions respectively
Pseudo-label refinement using superpixels for semi-supervised brain tumour segmentation
Training neural networks using limited annotations is an important problem in the medical domain. Deep Neural Networks (DNNs) typically require large, annotated datasets to achieve acceptable performance which, in the medical domain, are especially difficult to obtain as they require significant time from expert radiologists. Semi-supervised learning aims to overcome this problem by learning segmentations with very little annotated data, whilst exploiting large amounts of unlabelled data. However, the best-known technique, which utilises inferred pseudo-labels, is vulnerable to inaccurate pseudo-labels degrading the performance. We propose a framework based on superpixels - meaningful clusters of adjacent pixels - to improve the accuracy of the pseudo labels and address this issue. Our framework combines superpixels with semi-supervised learning, refining the pseudo-labels during training using the features and edges of the superpixel maps. This method is evaluated on a multimodal magnetic resonance imaging (MRI) dataset for the task of brain tumour region segmentation. Our method demonstrates improved performance over the standard semi-supervised pseudo-labelling baseline when there is a reduced annotator burden and only 5 annotated patients are available. We report DSC=0.824 and DSC=0.707 for the test set whole tumour and tumour core regions respectively
Gallium Arsenide (GaAs) Quantum Photonic Waveguide Circuits
Integrated quantum photonics is a promising approach for future practical and
large-scale quantum information processing technologies, with the prospect of
on-chip generation, manipulation and measurement of complex quantum states of
light. The gallium arsenide (GaAs) material system is a promising technology
platform, and has already successfully demonstrated key components including
waveguide integrated single-photon sources and integrated single-photon
detectors. However, quantum circuits capable of manipulating quantum states of
light have so far not been investigated in this material system. Here, we
report GaAs photonic circuits for the manipulation of single-photon and
two-photon states. Two-photon quantum interference with a visibility of 94.9
+/- 1.3% was observed in GaAs directional couplers. Classical and quantum
interference fringes with visibilities of 98.6 +/- 1.3% and 84.4 +/- 1.5%
respectively were demonstrated in Mach-Zehnder interferometers exploiting the
electro-optic Pockels effect. This work paves the way for a fully integrated
quantum technology platform based on the GaAs material system.Comment: 10 pages, 4 figure
Photon Pair Generation in Silicon Micro-Ring Resonator with Reverse Bias Enhancement
Photon sources are fundamental components for any quantum photonic
technology. The ability to generate high count-rate and low-noise correlated
photon pairs via spontaneous parametric down-conversion using bulk crystals has
been the cornerstone of modern quantum optics. However, future practical
quantum technologies will require a scalable integration approach, and
waveguide-based photon sources with high-count rate and low-noise
characteristics will be an essential part of chip-based quantum technologies.
Here, we demonstrate photon pair generation through spontaneous four-wave
mixing in a silicon micro-ring resonator, reporting a maximum
coincidence-to-accidental (CAR) ratio of 602 (+-) 37, and a maximum photon pair
generation rate of 123 MHz (+-) 11 KHz. To overcome free-carrier related
performance degradations we have investigated reverse biased p-i-n structures,
demonstrating an improvement in the pair generation rate by a factor of up to
2, with negligible impact on CAR.Comment: 5 pages, 3 figure
Vitrification within a nanoliter volume : oocyte and embryo cryopreservation within a 3D photopolymerized device
Open Access funding enabled and organized by CAUL and its Member Institutions. KRD is supported by a Mid-Career Fellowship from the Hospital Research Foundation (C-MCF-58–2019). KD acknowledges funding from the UK Engineering and Physical Sciences Research Council (grants EP/P030017/1). This study was funded by the Australian Research Council (ARC) Centre of Excellence for Nanoscale BioPhotonics (CE140100003).Purpose Vitrification permits long-term banking of oocytes and embryos. It is a technically challenging procedure requiring direct handling and movement of cells between potentially cytotoxic cryoprotectant solutions. Variation in adherence to timing, and ability to trace cells during the procedure, affects survival post-warming. We hypothesized that minimizing direct handling will simplify the procedure and improve traceability. To address this, we present a novel photopolymerized device that houses the sample during vitrification. Methods The fabricated device consisted of two components: the Pod and Garage. Single mouse oocytes or embryos were housed in a Pod, with multiple Pods docked into a Garage. The suitability of the device for cryogenic application was assessed by repeated vitrification and warming cycles. Oocytes or early blastocyst-stage embryos were vitrified either using standard practice or within Pods and a Garage and compared to non-vitrified control groups. Post-warming, we assessed survival rate, oocyte developmental potential (fertilization and subsequent development) and metabolism (autofluorescence). Results Vitrification within the device occurred within ~ 3 nL of cryoprotectant: this volume being ~ 1000-fold lower than standard vitrification. Compared to standard practice, vitrification and warming within our device showed no differences in viability, developmental competency, or metabolism for oocytes and embryos. The device housed the sample during processing, which improved traceability and minimized handling. Interestingly, vitrification-warming itself, altered oocyte and embryo metabolism. Conclusion The Pod and Garage system minimized the volume of cryoprotectant at vitrification—by ~ 1000-fold—improved traceability and reduced direct handling of the sample. This is a major step in simplifying the procedure.Publisher PDFPeer reviewe
Undifferentiated febrile illness in Kathmandu, Nepal.
Undifferentiated febrile illnesses (UFIs) are common in low- and middle-income countries. We prospectively investigated the causes of UFIs in 627 patients presenting to a tertiary referral hospital in Kathmandu, Nepal. Patients with microbiologically confirmed enteric fever (218 of 627; 34.8%) randomized to gatifloxacin or ofloxacin treatment were previously reported. We randomly selected 125 of 627 (20%) of these UFI patients, consisting of 96 of 409 (23%) cases with sterile blood cultures and 29 of 218 (13%) cases with enteric fever, for additional diagnostic investigations. We found serological evidence of acute murine typhus in 21 of 125 (17%) patients, with 12 of 21 (57%) patients polymerase chain reaction (PCR)-positive for Rickettsia typhi. Three UFI cases were quantitative PCR-positive for Rickettsia spp., two UFI cases were seropositive for Hantavirus, and one UFI case was seropositive for Q fever. Fever clearance time (FCT) for rickettsial infection was 44.5 hours (interquartile range = 26-66 hours), and there was no difference in FCT between ofloxacin or gatifloxacin. Murine typhus represents an important cause of predominantly urban UFIs in Nepal, and fluoroquinolones seem to be an effective empirical treatment
High-extinction ratio integrated photonic filters for silicon quantum photonics
We present the generation of quantum-correlated photon
pairs and subsequent pump rejection across two
silicon-on-insulator photonic integrated circuits. Incoherently
cascaded lattice filters are used to provide over
100 dB pass-band to stop-band contrast with no additional
external filtering. Photon pairs generated in a
microring resonator are successfully separated from the
input pump, confirmed by a temporal correlations measurements
- …