12 research outputs found

    Fenestrated aortic endograft branching with Gore VBX poses failure risk from delayed-onset branch kinking

    No full text
    The Gore VBX stent graft (Gore Medical, Flagstaff, Ariz) provides a new option for branching of fenestrated aortic endografts. However, its modular stent structure has raised concerns about potential kinking at the interspace between stent rings if lateralizing force exists between the fenestration and target vessel orifice. We present a case of near-occlusion of a VBX celiac branch due to narrowing of this interspace identified at postoperative month 3. Although the Gore VBX offers several potential advantages as a branch endoprosthesis, its design poses the risk of unpredictable, delayed-onset kinking and raises concern for its use as a fenestrated endograft branch. Keywords: Fenestrated endograft, Stent, Branc

    Acute ischemia secondary to popliteal artery stent fracture and embolization

    No full text
    Femoropopliteal disease comprises more than one half of lesions in peripheral vascular disease. The treatment modalities for stenosis or occlusion of this anatomic region include femoropopliteal bypass and percutaneous transluminal angioplasty with or without stenting. Our patient developed acute leg ischemia 3 years after stenting, secondary to stent fracture, with distal embolization of stent fragments. Using mechanical thromboembolectomy and superficial femoral artery to below-the-knee popliteal in situ saphenous vein bypass, we were able to restore perfusion to the limb and retrieve fragments of the fractured stent

    Successful use of continuous vasodilator infusion to treat critical vasospasm threatening a distal bypass

    No full text
    Vasospasm immediately after lower extremity arterial bypass may represent an uncommon cause of early graft failure. We report a successful case of catheter-directed, intra-arterial continuous vasodilator infusion to salvage a bypass graft threatened by severe, refractory vasospasm after incomplete response to nicardipine, verapamil, and nitroglycerin boluses. A continuous nitroglycerin infusion was administered for 24 hours, by which time the vasospasm resolved. At 12 months postoperatively, the graft remained patent with normal results of vascular laboratory studies. This report demonstrates that in cases of refractory vasospasm after peripheral bypass, continuous vasodilator infusion can be an effective treatment to prevent early graft failure

    Current status of patient-reported outcome measures in vascular surgery

    No full text
    A previously published review focused on generic and disease-specific patient-reported outcome measures (PROMs) relevant to vascular surgery but limited to arterial conditions. The objective of this project was to identify all available PROMs relevant to diseases treated by vascular surgeons and to evaluate vascular surgeon perceptions, barriers to widespread implementation, and concerns regarding PROMs. We provide an overview of what a PROM is and how they are developed, and summarize currently available PROMs specific to vascular surgeons. We also report results from a survey of 78 Society for Vascular Surgery members serving on committees within the Policy and Advocacy Council addressing the barriers and facilitators to using PROMs in clinical practice. Finally, we report the qualitative results of two focus groups conducted to assess granular perceptions of PROMS and preparedness of vascular surgeons for widespread implementation of PROMs. These focus groups identified a lack of awareness of existing PROMs, knowledge of how PROMs are developed and validated, and clarity around how PROMs should be used by the clinician as main subthemes for barriers to PROM implementation in clinical practice

    Factors associated with successful median arcuate ligament release in an international, multi-institutional cohort

    Get PDF
    Objective: Prior research on median arcuate ligament syndrome has been limited to institutional case series, making the optimal approach to median arcuate ligament release (MALR) and resulting outcomes unclear. In the present study, we compared the outcomes of different approaches to MALR and determined the predictors of long-term treatment failure. Methods: The Vascular Low Frequency Disease Consortium is an international, multi-institutional research consortium. Data on open, laparoscopic, and robotic MALR performed from 2000 to 2020 were gathered. The primary outcome was treatment failure, defined as no improvement in median arcuate ligament syndrome symptoms after MALR or symptom recurrence between MALR and the last clinical follow-up. Results: For 516 patients treated at 24 institutions, open, laparoscopic, and robotic MALR had been performed in 227 (44.0%), 235 (45.5%), and 54 (10.5%) patients, respectively. Perioperative complications (ileus, cardiac, and wound complications; readmissions; unplanned procedures) occurred in 19.2% (open, 30.0%; laparoscopic, 8.9%; robotic, 18.5%; P < .001). The median follow-up was 1.59 years (interquartile range, 0.38-4.35 years). For the 488 patients with follow-up data available, 287 (58.8%) had had full relief, 119 (24.4%) had had partial relief, and 82 (16.8%) had derived no benefit from MALR. The 1- and 3-year freedom from treatment failure for the overall cohort was 63.8% (95% confidence interval [CI], 59.0%-68.3%) and 51.9% (95% CI, 46.1%-57.3%), respectively. The factors associated with an increased hazard of treatment failure on multivariable analysis included robotic MALR (hazard ratio [HR], 1.73; 95% CI, 1.16-2.59; P = .007), a history of gastroparesis (HR, 1.83; 95% CI, 1.09-3.09; P = .023), abdominal cancer (HR, 10.3; 95% CI, 3.06-34.6; P < .001), dysphagia and/or odynophagia (HR, 2.44; 95% CI, 1.27-4.69; P = .008), no relief from a celiac plexus block (HR, 2.18; 95% CI, 1.00-4.72; P = .049), and an increasing number of preoperative pain locations (HR, 1.12 per location; 95% CI, 1.00-1.25; P = .042). The factors associated with a lower hazard included increasing age (HR, 0.99 per increasing year; 95% CI, 0.98-1.0; P = .012) and an increasing number of preoperative diagnostic gastrointestinal studies (HR, 0.84 per study; 95% CI, 0.74-0.96; P = .012) Open and laparoscopic MALR resulted in similar long-term freedom from treatment failure. No radiographic parameters were associated with differences in treatment failure. Conclusions: No difference was found in long-term failure after open vs laparoscopic MALR; however, open release was associated with higher perioperative morbidity. These results support the use of a preoperative celiac plexus block to aid in patient selection. Operative candidates for MALR should be counseled regarding the factors associated with treatment failure and the relatively high overall rate of treatment failure
    corecore