Financial implications of the current Washington Special Education Funding Formula for the 1980-81 school year were studied. Financial data for 229 school districts which provided education for handicapped children was collected for the study. The results showed that the majority of school districts which provide education for handicapped children did not receive funding equal to expenditures for education programs for the 1980-81 school year. Recommendations for increasing Washington\u27s funding for handicapped education programs are discussed
Étude des interactions entre phénomènes d'incendie et systèmes d'extinction à eau. Développement d'un module d'extinction dans le logiciel FDS
This work is devoted to the study of interactions between fuel, flame and water droplets generated by water mist systems. It is completed by an extinction model development in FDS (Fire Dynamics Simulator) software, which is a CFD code widely used by the scientific and engineering communities. Knowledge on physical phenomena induced by water application on fire is acquired thanks to an experimental campaign at real scale. 84 confined and ventilated fire tests have been carried out involving water mist and metrology allowing to study the influence on extinction of: fuel, combustion time before water mist application, pool diameter for liquid fuel fires, number of nozzles and fuel location. A post-processing in the form of mass and energy balances has been added to FDS, allowing to complete experimental observations and to quantify the different heat transfer modes before and during water application. Two complementary models allow extinction determination by fuel cooling and flame cooling / inerting effects. Their capability is analyzed for appropriate cases on the versions 5 and 6 of FDS. The capability of the complete modified code to predict extinction is finally evaluatedCe travail est consacré à l'étude des interactions entre combustible, flamme et gouttes d'eau générées par des systèmes de type brouillard d'eau. Il est complété par le développement d'un modèle d'extinction dans le logiciel FDS (Fire Dynamics Simulator), code CFD largement utilisé dans la communauté scientifique et dans l'ingénierie. L'acquisition de connaissances sur les phénomènes physiques induits par l'application d'un spray sur un feu résulte de l'analyse d'une campagne expérimentale à échelle réelle. 84 essais de feux confinés et ventilés ont ainsi été réalisés faisant intervenir un brouillard d'eau et une instrumentation qui permet d'étudier l'influence sur l'extinction: du combustible, du temps de combustion avant déclenchement du brouillard d'eau, du diamètre du bac pour les feux de liquide inflammable, du nombre de buses et du placement du foyer. L'ajout d'un post-traitement au logiciel FDS sous la forme de bilans de masse et d'énergie dans le code permet de compléter les observations expérimentales et de quantifier l'importance des différents transferts thermiques avant et pendant l'aspersion d'eau. Deux modèles complémentaires permettent de déterminer l'extinction par refroidissement du combustible et par refroidissement de la flamme / inertage. Ils sont étudiés pour des cas appropriés sur les versions 5 et 6 de FDS. La capacité du code complet modifié à prédire l'extinction est évalué
Study of the interactions between fire and water mist systems. Development of a suppression model for FDS software
Ce travail est consacré à l'étude des interactions entre combustible, flamme et gouttes d'eau générées par des systèmes de type brouillard d'eau. Il est complété par le développement d'un modèle d'extinction dans le logiciel FDS (Fire Dynamics Simulator), code CFD largement utilisé dans la communauté scientifique et dans l'ingénierie. L'acquisition de connaissances sur les phénomènes physiques induits par l'application d'un spray sur un feu résulte de l'analyse d'une campagne expérimentale à échelle réelle. 84 essais de feux confinés et ventilés ont ainsi été réalisés faisant intervenir un brouillard d'eau et une instrumentation qui permet d'étudier l'influence sur l'extinction: du combustible, du temps de combustion avant déclenchement du brouillard d'eau, du diamètre du bac pour les feux de liquide inflammable, du nombre de buses et du placement du foyer. L'ajout d'un post-traitement au logiciel FDS sous la forme de bilans de masse et d'énergie dans le code permet de compléter les observations expérimentales et de quantifier l'importance des différents transferts thermiques avant et pendant l'aspersion d'eau. Deux modèles complémentaires permettent de déterminer l'extinction par refroidissement du combustible et par refroidissement de la flamme / inertage. Ils sont étudiés pour des cas appropriés sur les versions 5 et 6 de FDS. La capacité du code complet modifié à prédire l'extinction est évaluéeThis work is devoted to the study of interactions between fuel, flame and water droplets generated by water mist systems. It is completed by an extinction model development in FDS (Fire Dynamics Simulator) software, which is a CFD code widely used by the scientific and engineering communities. Knowledge on physical phenomena induced by water application on fire is acquired thanks to an experimental campaign at real scale. 84 confined and ventilated fire tests have been carried out involving water mist and metrology allowing to study the influence on extinction of: fuel, combustion time before water mist application, pool diameter for liquid fuel fires, number of nozzles and fuel location. A post-processing in the form of mass and energy balances has been added to FDS, allowing to complete experimental observations and to quantify the different heat transfer modes before and during water application. Two complementary models allow extinction determination by fuel cooling and flame cooling / inerting effects. Their capability is analyzed for appropriate cases on the versions 5 and 6 of FDS. The capability of the complete modified code to predict extinction is finally evaluate
Intérêt de santé publique et individuel du certificat de santé du vingt-quatriéme mois, par une revue bibliographique
Le certificat de santé obligatoire du vingt-quatrième mois n'a pas fait l'objet, depuis sa création, d'une évaluation de son intérêt en terme de santé publique ou individuelle. Au niveau épidémiologique ce certificat est une source de données de valeur, surtout devant l'absence de tout autre source de données concernant cette classe d'âge. Son intérêt est certain dans la connaissance et l'amélioration de la couverture vaccinale. Au niveau individuel, le certificat de santé du vingt-quatrième mois n'est important que dans le dépistage des troubles praxiques et des troubles autistiques. Le dépistage et la prise en charge des retards de langage, des troubles de l'audition, de la vision, de la croissance, de l'obésité, et du comportements, ne concerne pas spécifiquement cet examen, hormis dans le cadre d'un suivi régulier global de l'enfant et de son environnement social.GRENOBLE1-BU Médecine pharm. (385162101) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF
Étude des interactions entre phénomènes d'incendie et systèmes d'extinction à eau. Développement d'un module d'extinction dans le logiciel FDS
Ce travail est consacré à l'étude des interactions entre combustible, flamme et gouttes d'eau générées par des systèmes de type brouillard d'eau. Il est complété par le développement d'un modèle d'extinction dans le logiciel FDS (Fire Dynamics Simulator), code CFD largement utilisé dans la communauté scientifique et dans l'ingénierie. L'acquisition de connaissances sur les phénomènes physiques induits par l'application d'un spray sur un feu résulte de l'analyse d'une campagne expérimentale à échelle réelle. 84 essais de feux confinés et ventilés ont ainsi été réalisés faisant intervenir un brouillard d'eau et une instrumentation qui permet d'étudier l'influence sur l'extinction: du combustible, du temps de combustion avant déclenchement du brouillard d'eau, du diamètre du bac pour les feux de liquide inflammable, du nombre de buses et du placement du foyer. L'ajout d'un post-traitement au logiciel FDS sous la forme de bilans de masse et d'énergie dans le code permet de compléter les observations expérimentales et de quantifier l'importance des différents transferts thermiques avant et pendant l'aspersion d'eau. Deux modèles complémentaires permettent de déterminer l'extinction par refroidissement du combustible et par refroidissement de la flamme / inertage. Ils sont étudiés pour des cas appropriés sur les versions 5 et 6 de FDS. La capacité du code complet modifié à prédire l'extinction est évaluéeThis work is devoted to the study of interactions between fuel, flame and water droplets generated by water mist systems. It is completed by an extinction model development in FDS (Fire Dynamics Simulator) software, which is a CFD code widely used by the scientific and engineering communities. Knowledge on physical phenomena induced by water application on fire is acquired thanks to an experimental campaign at real scale. 84 confined and ventilated fire tests have been carried out involving water mist and metrology allowing to study the influence on extinction of: fuel, combustion time before water mist application, pool diameter for liquid fuel fires, number of nozzles and fuel location. A post-processing in the form of mass and energy balances has been added to FDS, allowing to complete experimental observations and to quantify the different heat transfer modes before and during water application. Two complementary models allow extinction determination by fuel cooling and flame cooling / inerting effects. Their capability is analyzed for appropriate cases on the versions 5 and 6 of FDS. The capability of the complete modified code to predict extinction is finally evaluatedNANCY-INPL-Bib. électronique (545479901) / SudocSudocFranceF
Peut-on déterminer l'extinction d'un feu par brouillard d'eau avec FDS ?
La détermination du temps d’extinction d’un foyer par simulation numérique doit être précise et fiable pour la sécurité incendie. Cette étude est le fruit d’une collaboration entre le CNPP et le LEMTA, qui propose de tester les différents modes d’extinction disponibles sur FDS (Fire Dynamics Simulator) à partir de données expérimentales. Ces essais sont obtenus sur des feux de fioul éteints par brouillards d’eau dans une pièce ventilée. Deux essais sont présentés dans cette contribution, montrant des mécanismes d’extinction différents. Dans le premier essai (cas 1), l’extinction est attribuée au refroidissement du combustible, alors que le refroidissement de la phase gazeuse et l’inertage, résultant d’une forte évaporation, sont prépondérants dans le second (cas 2). Ces deux comportements distincts sont obtenus en jouant sur le temps de déclenchement du brouillard d’eau (respectivement 1 et 5 minutes), occasionnant des HRR (Heat Release Rate) et des champs de températures différents. Ces observations expérimentales sont confirmées par des résultats numériques faisant intervenir des bilans d’énergie intégrés à FDS. Dans FDS 6, le critère d’extinction par refroidissement de la flamme et inertage est basé sur un bilan énergétique alors que le modèle d’extinction par refroidissement du combustible consiste en une diminution du débit de pyrolyse selon une loi exponentielle. Cette loi fait intervenir la densité surfacique d’eau présente sur la surface de combustible et un facteur de calage. Ce modèle a été testé sur le cas 1 (extinction par refroidissement du combustible) et démontre que le coefficient de calage est un paramètre très sensible ce qui limite l’utilisation de cette loi. Cette comparaison justifie alors l’écriture d’un nouveau modèle. Celui-ci est dérivé d’une loi type Arrhénius et lie ainsi le débit de pyrolyse à la température de surface du combustible durant l’aspersion. Les résultats obtenus à l’aide de ce nouveau modèle seront présentés
Experimental and numerical study of pool fire suppression using water mist
International audienceExperiments in a real-scale room were done on water mist application to a pool fire. A fire produced with fuel oil in a 35 cm cylindrical pool was used, with a heat release rate reaching 75 kW in stationary conditions. Water application was studied with a nominal flow rate equal to 25 l/min provided by a set of four nozzles, injecting droplets with mean Sauter diameter equal to 112 μ m . Observations of fire suppression in these conditions showed two behaviors, which were analyzed and detailed with the help of numerical simulations conducted with FDS.v5. On one hand, a fast suppression (about 10 s required) was observed when water mist was applied to a developed fire. In this case, droplets were injected into a hot environment and thus evaporated strongly, generating a significant vapor concentration and resulting in a fast gas cooling and in an inerting effect. On the other hand, when the mist was applied early, fire growth was controlled, but its suppression required a longer application (about 1 min) and only occurred after a significant cooling of the flame and the liquid pool. These two mechanisms were detailed numerically through mass and energy balances for both the gas and the liquid phases and could help to derive suppression model improvements
Can we predict fire extinction by water mist with FDS?
International audienceAmong the primary phenomena observed when studying fire suppression are fuel surface cooling, fire plume cooling and inerting effects. The last two result from water evaporation generating a significant vapor concentration, thus leading to an important heat sink as well as displacement and dilution of both oxygen and fuel vapor. Fire Dynamics Simulator (FDS.v6) is expected to be able to reproduce these effects. Extinguishment criterion focusing on plume cooling and inerting effects is based on a dedicated heat balance, whereas suppression model related to fuel surface cooling evaluates the burning rate decrease according to an exponential law taking into account local water mass reaching the fuel surface per unit area and an empirical constant which penalizes the prediction ability. Therefore, a new model derived from an Arrhenius equation has been implemented, which links the burning rate to the fuel surface temperature. Numerical simulations are conducted and compared with experimental data for all extinguishing mechanisms
Modeling of fire suppression by fuel cooling
International audienceFire suppression with water spray was investigated, focusing on cases where fuel cooling is the dominant suppression mechanism, with the aim to add a specific suppression model addressing this mechanism in Fire Dynamics Simulator (FDS), which already involves a suppression model addressing effects related to flame cooling. A series of experiments was selected, involving round pools of either 25 or 35 cm diameter and using both diesel and fuel oil, in a well-ventilated room. The fire suppression system is designed with four nozzles delivering a total flow rate of 25 l/min and injecting droplets with mean Sauter diameter 112 μm. Among the 74 tests conducted in various conditions, 12 cases with early spray activation were especially considered, as suppression was observed to require a longer time to cool the fuel surface below the ignition temperature. This was quantified with fuel surface temperature measurements and flame video recordings in particular. A model was introduced simulating the reduction of the pyrolysis rate during the water spray application, in relation to the decrease of the fuel local temperature. The numerical implementation uses the free-burn step of the fire to identify the relationship between pyrolysis rate and fuel surface temperature, assuming that the same relationship is kept during the fire suppression step. As expected, numerical simulations reproduced a sharp HRR decrease following the spray activation in all tests and the suppression was predicted in all cases where it was observed experimentally. One specific case involving a water flow rate reduced such that it is too weak to allow complete suppression was successfully simulated. Indeed, the simulation showed a reduced HRR but a fire not yet suppressed. However, most of the tests showed an under-estimated duration before fire suppression (discrepancy up to 26 s for a spray activation lasting 73 s), which demonstrates the need for model improvement. In particular the simulation of the surface temperature should require a dedicated attention. Finally, when spray activation occurred in hotter environments, probably requiring a combination of fuel cooling and flame cooling effects, fire suppression was predicted but with an over-estimated duration. These results show the need for further modeling efforts to combine in a satisfactory manner the flame cooling model of FDS and the present suggested model for fuel cooling