34 research outputs found

    Effets des agents anesthésiques sur les paramÚtres électrophysiologiques impliqués dans la genÚse des réentrées ventriculaires

    No full text
    MONTPELLIER-BU MĂ©decine UPM (341722108) / SudocPARIS-BIUP (751062107) / SudocMONTPELLIER-BU MĂ©decine (341722104) / SudocSudocFranceF

    Collinearity and multivariable analysis

    No full text

    Magnetic needle‐tracking device for ultrasound guidance of radial artery puncture: A randomized study on a simulation model

    No full text
    International audienceUltrasound-guidance of radial artery catheter insertion improves the first attempt success and reduces the occurrence of hematomas. Needle-tracking devices optimize needle-ultrasound beam alignment by displaying in real-time the needle tip position. We compared the median time need by experienced physicians to achieve radial artery puncture using either a conventional ultrasonography device (CUD) or a magnetic needle-tracking ultrasound device (MUD) in a simulation training arm model.Methods: Fifty experienced residents and physicians performed two punctures in randomized order with the CUD and the MUD. The primary outcome was puncture duration; the secondary outcomes were puncture success, rate of accidental vein puncture, and practitioner's comfort (subjective scale 0-10).Results: The median [lower-upper quartile] puncture time was 10 [6-14] seconds when using CUD and 4 [3-7] seconds when using MUD (P < .01). In the multivariate analysis, MUD use was associated with decreased puncture duration whatever the puncture order (OR 1.13 [1.07-1.20], P < .01). The participants performed 99 (99%) successful punctures: 50 with the MUD (100%) and 49 with the CUD (98%). There was no accidental venous puncture. The practitioner's comfort level was 6.5 [6, 7] with the CUD and 8 [7-9] with the MUD (P < .01).Conclusion: MUD reduced radial artery puncture time and improved physician comfort in a simulation training arm model

    Integration of lung ultrasound in the diagnostic reasoning in acute dyspneic patients: A prospective randomized study

    No full text
    International audienceINTRODUCTION:Misdiagnosis in acute dyspneic patients (ADP) has consequences on their outcome. Lung ultrasound (LUS) is an accurate tool to improve diagnostic performance. The main goal of this study was to assess the determinants of increased diagnostic accuracy using LUS.MATERIALS:Multicentre, prospective, randomized study including emergency physicians and critical care physicians treating ADP on a daily basis. Each participant received three difficult clinical cases of ADP: one with only clinical data (OCD), one with only LUS data (OLD), and one with both. Ultrasound video loops of A, B and C profiles were associated with the cases. Which physician received what data for which clinical case was randomized. Physicians assessed the diagnostic probability from 0 to 10 for each possible diagnosis. The number of uncertain diagnoses (NUD) was the number of diagnoses with a diagnostic probability between 3 and 7, inclusive.RESULTS:Seventy-six physicians responded to the study cases (228 clinical cases resolved). Among the respondents, 28 (37%) were female, 64 (84%) were EPs, and the mean age was 37±8 years. The mean NUDs, respectively, when physicians had OCD, OLD, and both were 2.9±1.8, 2.2±1.7, 2.2±1.8 (p = 0.02). Ultrasound data and ultrasound frequency of use were the only variables related to the NUD. Higher frequency of ultrasound use by physicians decreased the number of uncertain diagnoses in difficult clinical cases with ultrasound data (OLD or associated with clinical data).CONCLUSION:LUS decreases the NUD in ADP. The ultrasound frequency of use decreased the NUD in ADP clinical cases with LUS data

    Global longitudinal strain changes during hemorrhagic shock: An experimental study

    No full text
    International audienceOBJECTIVES: Global longitudinal strain (GLS) appears sensitive and reproducible to identify left ventricular systolic dysfunction. The main objective was to analyze the GLS changes in an anesthetized-piglet model of controlled hemorrhagic shock (HS). The secondary objective was to evaluate if GLS changes was different depending on the expansion fluid treatment with or without norepinephrine.METHODS: Eighteen anesthetized and ventilated piglets were bled until the mean arterial pressure reached 40 mmHg. Controlled hemorrhage was maintained for 30 min before randomizing the piglets to three resuscitation groups: control group, LR group (resuscitated with lactated ringer), and NA group (resuscitated with lactated ringer and norepinephrine).RESULTS: There was no difference in the baseline hemodynamic, biological, and ultrasound data among the three groups. During the hemorrhagic phase, the GLS increased significantly from 25 mL/kg of depletion. During the resuscitation phase, the GLS decreased significantly from 20 mL/kg of fluid administration. There was no difference in GLS variation among the groups during the hemorrhagic, maintenance, and resuscitation phases.CONCLUSION: In our HS model, GLS increased with hemorrhage and decreased during resuscitation, showing its preload dependence

    Prescription errors by emergency physicians for inpatients are associated with emergency department length of stay

    No full text
    International audienceOBJECTIVES:Adverse drug events are the sixth-leading cause of death in Western countries and are also more frequent in emergency departments (EDs). In some hospitals or on some occasions, ED physicians prescribe for patients who they have admitted. These prescriptions are then followed by the wards and can persist for several days. Our objectives were to determine the frequency of prescription errors for patients over 18years old hospitalized from ED to medical or surgical wards, and whether there exists a relationship between those prescription errors and ED LOS.METHODS:This was a single center retrospective study that was conduct in the ED of a university hospital with an annual census of 65 000 patients. The population studied consisted of patients over 18years old hospitalized from ED to medical or surgical wards between January 1st, 2012 and January 21st, 2012.RESULTS:Six hundred eight patients were included. One hundred fifty-four (25%) patients had prescription errors. Prescription errors were associated with increased ED length of stay (OR=2.47; 95% CIs [1.58; 3.92]) and polypharmacy (OR=1.78; 95% CIs [1.20; 2.66]). Fewer prescription errors were found when the patient was examined in the ED by a consultant (OR=0.61; 95% CIs [0.41; 0.91]) and when the medical history was known (OR=0.28; 95% CIs [0.10; 0.88]).CONCLUSION:Prescription errors occurred frequently in the ED. We assume that a clear communication and cooperation between EPs and consultants may help improve prescription accuracy
    corecore