295 research outputs found

    Validation of whole slide imaging in the primary diagnosis of gynaecological pathology in a University Hospital

    Get PDF
    AIMS: Experience in the use of whole slide imaging (WSI) for primary diagnosis in pathology is very limited. We aimed to determine the accuracy of interpretation of WSI compared with conventional light microscopy (CLM) in the diagnosis of routine gynaecological biopsies. METHODS: All gynaecological specimens (n=452) received over a 2-month period at the Department of Pathology of the Hospital Clinic of Barcelona were analysed blindly by two gynaecological pathologists, one using CLM and the other WSI. All slides were digitised in a Ventana iScan HT (Roche diagnostics) at 200×. All discrepant diagnoses were reviewed, and a final consensus diagnosis was established. The results were evaluated by weighted κ statistics for two observers. RESULTS: The level of interobserver agreement between WSI and CLM evaluations was almost perfect (κ value: 0.914; 95% CI 0.879 to 0.949) and increased during the study period: κ value 0.890; 95% CI 0.835 to 0.945 in the first period and 0.941; 95%; CI 0.899 to 0.983 in the second period. Major discrepancies (differences in clinical management or prognosis) were observed in 9 cases (2.0%). All discrepancies consisted of small lesions (8 high grade squamous intraepithelial lesions of the uterine cervix, one lymph node micrometastasis of an ovarian carcinoma) underdiagnosed or missed in the WSI or the CLM evaluation. Discrepancies with no or minor clinical relevance were identified in 3.8% of the biopsies. No discrepancy was related to the poor quality of the WSI image. CONCLUSIONS: Diagnosis of gynaecological specimens by WSI is accurate and may be introduced into routine diagnosis

    Resuscitating the Dying Autopsy

    Get PDF
    Summary points Despite the relevant information that postmortem examinations can provide, autopsy rates have been declining worldwide in the last few decades. Autopsies are especially necessary in low-income countries, where reliable information on cause of death is much more limited and in vivo clinical diagnosis is hampered by the scarce availability of diagnostic tools. The use of the autopsy or of robust substitutes for this procedure needs to be encouraged as a mechanism for the continuous improvement of clinical diagnosis and as a complement for cause-of-death investigation and surveillance

    Fracaso del cartílago costal en el tratamiento de defectos óseos experimentales: Estudio histológico y radiológico

    Get PDF
    Se realiza un estudio experimental para demostrar la utilidad del cartílago costal, fresco o criopreservado (autólogo y homólogo), en el tratamiento de defectos óseos cavitarios de huesos largos y observar si la radiología simple es fiable para la valoración de su incorporación. Para ello se implanta cartílago costal, sin pericondrio, en un defecto óseo cavitario de la metáfisis distal del fémur de conejo. Se utilizan dos tipos de injerto según su procedencia (antólogo y homólogo) y el procedimiento de conservación (fresco y criopreservado). Se trabaja sobre 3 grupos de 6 conejos cada uno. Se valora la incorporación del injerto mediante histología y radiología simple, a las 3, 6 y 12 semanas. Las conclusiones de este trabajo demuestran que el implante de cartílago costal no actúa como elemento osteoinductor; la radiología simple no es un método fiable para la valoración de la incorporación del injerto.An experimental study was carried out to demonstrate the utility of costal, fresh or cryopreserved cartilage (autologus and homologous), in the treatment of cavitary bone defects of long bones and to observe whether simple radiology is reliable for assessing of its incorporation. The study involved implanting costal cartilage, without perichondrial tissue, in a cavitary bone defect of the distal metafisis in rabbit femur. Two types of graft were used, according to their origin (autologus and homologous) and to the conservation procedure (fresh and cryopreserved). We workek on 3 separate groups of 6 rabbits. We assessed the incorporation of the graft by means of histology and simple radiology studies, at 3, 6 and 12 weeks. The conclusions of this work demonstrate that costal cartilage implants do not act as osteoinductor elements, and that simple radiology is not a reliable method for assessing the incorporation of the graft

    Validation of Whole-Slide Imaging for Histolopathogical Diagnosis: Current State

    Get PDF
    Rapid advances in informatics and technological improvements have led to the development of high-throughput whole-slide imaging (WSI) scanners able to produce high-quality digital images, which allow achieving a correct diagnosis of the biopsies using virtual viewers. This technology is currently prepared to be introduced in the departments of pathology for routine diagnosis. The aim of this review is to analyze the current evidence regarding the use of WSI in primary or routine diagnosis in the different subspecialties of pathology. An increasing number of studies have shown almost perfect inter- and intraobserver agreement between the diagnoses obtained with WSI and the classical diagnoses based on conventional light microscopy. The only exception seems to be cytology, which still requires some technological development. Although validation studies are needed in some areas of pathology, growing evidence indicates that WSI is a reliable tool for routine diagnosis. Pathologists have a positive perception of the ergonomics of the workstations, the low magnification of WSI and the possibility of making annotations and measurements. WSI can be used from any device and anywhere, thereby providing great opportunities for teleconsultation. New technologies such as the recognition of histopathology patterns using image analysis may facilitate diagnosis and improve the reproducibility among pathologists in the future

    Comparison of the Analytical and Clinical Performance of Five Tests for the Detection of Human Papillomavirus Genital Infection

    Get PDF
    HPV-based screening provides greater protection against cervical cancer (CC) than cytology-based strategies. Currently, several molecular diagnostic assays for the detection of human papillomavirus (HPV) are available. In this study, we analyzed 5 different HPV testing and genotyping techniques (Hybrid Capture 2 [HC2; Qiagen, Hilden, Germany], AnyplexTMII HPV28 [Anyplex; Seegene, Seoul, Korea], Linear Array [Roche, Branchburg, NJ, USA], GP5+/6+ PCR-EIA-RH [Labo Bio-medical Products, Rijswijk, The Netherlands] and CLART2 [Genomica, Madrid, Spain]) in 295 women referred to the hospital Colposcopy Clinic from 2007 to 2008 due to positive HPV test results or an abnormal Pap test. DNA extraction for HPV genotyping was performed in cervical sample specimens after Pap test and HPV detection by HC2. The inclusion criteria were: (1) adequate cervical sampling with sufficient material for the Pap test and HPV detection and genotyping, and (2) colposcopically-directed biopsy and/or endocervical curettage. HC2 showed the highest sensitivity for high-grade squamous intraepithelial lesion and CC (HSIL+) detection (96.1%), but all the HPV genotyping tests showed a higher specificity. (Anyplex 86.8%; Linear Array 86.0%; GP5+/6+ 78.8%; CLART2 76.5%). The agreement between HC2 results and the other techniques was similar: 82.4%, kappa=0.650 for Anyplex; 83.4%, kappa=0.670 for Linear Array, 79.93%, kappa=0.609 for GP5+/6+ and 82.4%, kappa=0.654 for CLART2. HPV 16 and/or 18 infection was a risk factor for underlying HSIL+ in the univariate analysis. Anyplex showed the highest risk of underlying HSIL+ after positive HPV 16 and/or 18 tests (OR 31.1; 95% IC 12.1-80.0)

    Current Status of Whole-Slide Imaging in Education

    Get PDF
    Conventional light microscopy (CLM) has classically been the basic tool to teach histology and pathology. In recent years, whole-slide imaging (WSI), which consists of generating a high-magnification digital image of an entire histological glass slide, has emerged as a useful alternative to CLM offering a myriad of opportunities for education. Navigation through the digitized slides closely simulates viewing glass slides with a microscope and is also referred to as virtual microscopy. WSI has many advantages for education. Students feel more comfortable with its use, and it can be used in any classroom as it only requires a computer with Internet access and it allows remote access from anywhere and from any device. WSI can be used simultaneously by a large number of people, stimulating cooperation between students and improving the interaction with the teachers. It allows making marks and annotations on specific fields, which enable specific directed questions to the teacher. Finally, WSI supports are cost-effective compared with CLM. Consequently, WSI has begun to replace CLM in many institutions. WSI has shown to be an extremely useful tool for undergraduate education (medical, dental and veterinary schools), for the training of residents of pathology, tele-education and in tumor boards

    HPV Vaccination as Adjuvant to Conization in Women with Cervical Intraepithelial Neoplasia: A Study under Real-Life Conditions

    Get PDF
    Background: Recent studies have shown preliminary evidence that vaccination against human papillomavirus (HPV) could decrease the risk of persistent/recurrent HSIL in women treated for high-grade cervical intraepithelial lesion (HSIL). We aimed to determine the benefits of HPV vaccination in patients undergoing conization for HSIL in real-life conditions and evaluate vaccination compliance associated with different funding policies. Methods: From January 2013 to July 2018, 265 women underwent conization in our center. From January 2013 to July 2017, treated patients (n = 131) had to pay for the vaccine, whereas after July 2017 the vaccine was publicly funded and free for treated women (n = 134). Post-conization follow-up controls were scheduled every six months with a Pap smear, HPV testing, and a colposcopy. Results: 153 (57.7%) women accepted vaccination (vaccinated group), and 112 (42.3%) refused the vaccine (non-vaccinated group). Persistent/recurrent HSIL was less frequent in vaccinated than in non-vaccinated women (3.3% vs. 10.7%, p = 0.015). HPV vaccination was associated with a reduced risk of persistent/recurrent HSIL (OR 0.2, 95%CI: 0.1–0.7, p = 0.010). Vaccination compliance increased when the vaccine was publicly funded (from 35.9% [47/131] to 79.1% [106/134], p < 0.001). Conclusions: HPV vaccination in women undergoing conization is associated with a 4.5-fold reduction in the risk of persistent/recurrent HSIL. Vaccination policies have an important impact on vaccination compliance

    Leukoerythroblastosis in a Young Child with Severe Malaria and Superimposed Gram Negative Infection

    Get PDF
    Background: Leukoerythroblastosis, a non-specific and often short-lasting response of the bone marrow to different diseases such as malignancies or infections, is characterized by the presence in the peripheral blood of immature red and white cells. Methods: We present a case of leukoerythoblastosis occurring in a 24 months old Mozambican girl, in the context of a severe malaria episode and an associated urinary tract infection. Peripheral blood smear was used for diagnosis of malaria and leukoerythroblastosis. Enterobacter cloacae isolation and antibiotic susceptibility testing were performed by conventional microbiology. Results: Peripheral blood smear was positive for Plasmodium falciparum and showed a leukoerythroblastosis with red cell anisopoikilocytosis and left shifted neutrophils. Urine culture confirmed the presence of a multi-resistant E. cloacae. Treatment of underlying conditions resolved the leukoerythroblastic reaction. Conclusions: Leukoerythroblastosis may be related to different infectious diseases and may also appear in the context of severe malaria. Bacterial superinfection needs to be investigated

    Healthcare providers’ views and perceptions on post-mortem procedures for cause of death determination in Southern Mozambique

    Get PDF
    Background: The minimally invasive autopsy (MIA) is being investigated as an alternative to the complete diagnostic autopsy (CDA), gold standard for CoD determination, in settings where CDA is unfeasible and/or unacceptable. We aimed to explore healthcare providers’ views and perceptions on theoretical and factual acceptability of the CDA and the MIA. Methods: A qualitative study, combining ethnographic and grounded-theory approaches, was conducted within a project aiming to validate the MIA tool against the CDA for CoD investigation. We present data on in-depth and semi-structured interviews of 33 healthcare providers operating within the formal and informal health services in Southern Mozambique. MIA perception was analysed through the theory of diffusion of innovations. Results: All participants considered CDA useful for CoD determination. CDA was perceived reliable, but the unpleasant nature of the procedure and its associated infection risk were the main perceived disadvantages. Participants considered the MIA simple, easy and quick to perform; likely to meet families’ expectations to know the CoD, and able to provide evidence-based knowledge for disease management. Concerns were raised on its reliability compared to the CDA. Family's emotional status and accessibility to decision-makers were mentioned as principal barriers for MIA performance. The main jeopardizing factors for MIA implementation were the shortage of required resources and the significant proportion of people dying at home. Key facilitators for MIA acceptance included the need for the support from community and religious leaders, provision of clear information to the community, and accompaniment to bereaved families. Conclusions: Healthcare providers consider the MIAs potentially more acceptable and feasible than CDAs in places where the latter have shown significant implementation challenges. A clear understanding of healthcare provider’s perceived barriers and facilitators for conducting post-mortem procedures in general, and MIAs in particular, will shed light on their future field implementation for more robust mortality surveillance
    corecore