137 research outputs found

    Vein graft surveillance: Is graft revision without angiography justified and what criteria should be used?

    Get PDF
    AbstractPurpose: The objective of this study was to assess the accuracy of color-flow duplex surveillance parameters to detect infrainguinal vein graft stenoses and to investigate whether graft revision without angiography is justified. Methods: In a prospective study in which three centers participated, the data of graft surveillance in 300 patients were analyzed. For the evaluation of surveillance criteria all patients underwent a digital subtraction angiography if a graft stenosis was suspected. To create a control group, in patients with normal grafts a consented digital subtraction angiography was performed also. From these data the accuracy of seven duplex and three ankle blood pressure-derived variables was assessed. The relation between various surveillance criteria and continued graft patency was determined with life table analysis with the transient state method. Results: The mean follow-up period was 20 months (range, 1 to 40 months). At univariate and multivariate analysis the peak systolic velocity (PSV) ratio provided the best correlation with angiographic stenoses ≥70% (PSV ratio cutoff 3.0: sensitivity 80%, specificity 84%). This finding did not differ between the participating centers. With life table methods it was demonstrated that the best combination of efficacy (limitation of the number of unnecessary revisions), safety (minimal number of correctable lesions missed), and reduction of angiograms was obtained by a two-parameter surveillance algorithm. This algorithm included a PSV ratio <2.5 to delineate patients in whom a conservative approach without angiography or revision was appropriate, a PSV ratio ≥4.0 to indicate patients in whom vein graft revision without angiography could be scheduled, and a group with PSV ratios between 2.5 and 4.0 in whom angiography was to be performed to determine clinical management on the basis of the stenosis severity. This algorithm had a positive predictive value of 93% and a negative predictive value of 89%. In addition, it resulted in a reduction of the number of angiograms of 49% compared with a policy of angiographies in all patients with a PSV ratio ≥2.5. Conclusions: The best criterion to identify a failing graft is the PSV ratio. With a two-parameter algorithm for vein graft surveillance, the incidence of unnecessary revisions and of missed high-grade lesions was acceptably low, whereas the number of angiograms was reduced by one half. (J Vasc Surg 1998;27:399-413.

    A randomized multicenter study of the outcome of brachial-basilic arteriovenous fistula and prosthetic brachial-antecubital forearm loop as vascular access for hemodialysis

    Get PDF
    BackgroundVascular access is a necessity for patients with end-stage renal disease who need chronic intermittent hemodialysis. According to Kidney Disease Outcomes Quality Initiative (KDOQI) guidelines, radial-cephalic (RC) and brachial-cephalic (BC) arteriovenous fistulas (AVF) are the first and second choice for vascular access, respectively. If these options are not possible, an autogenous brachial-basilic fistula in the upper arm (BBAVF) or a prosthetic brachial-antecubital forearm loop (PTFE loop) may be considered. Until now, it was not clear which access type was preferable. We have performed a randomized study comparing BBAVF and prosthetic implantation in patients without the possibility for RCAVF or BCAVF.MethodsPatients with failed primary/secondary access or inadequate arterial and/or venous vessels were randomized for either BBAVF or PTFE loop creation. The numbers of complications and interventions were recorded. Kaplan-Meier method was used to calculate primary, assisted-primary and secondary patency rates. The patency rates were compared with the log-rank test. Complication and intervention rates were compared with the Mann-Whitney test.ResultsA total of 105 patients were randomized for a BBAVF or PTFE loop (52 vs 53, respectively). Primary and assisted-primary 1-year patency rates were significantly higher in the BBAVF group: 46% ± 7.4% vs 22% ± 6.1% (P = .005) and 87% ± 5.0% vs 71% ± 6.7% (P = .045) for the BBAVF and PTFE group, respectively. Secondary patencies were comparable for both groups; 89% ± 4.6% vs 85% ± 5.2% for the BBAVF and PTFE group, respectively. The incidence rate of complications was 1.6 per patient-year in the BBAVF group vs 2.7 per patient-year in the PTFE group. Patients in the BBAVF group needed a total of 1.7 interventions per patient-year vs 2.7 per patient-year for the PTFE group.ConclusionThese data show a significantly better primary and assisted-primary patency in the BBAVF group compared with the PTFE group. Furthermore, in the BBAVF group, fewer interventions were needed. Therefore, we conclude that BBAVF is the preferred choice for vascular access if RCAVF or BCAVF creation is impossible, or when these types of access have already failed

    Patient-Specific Computational Modeling of Upper Extremity Arteriovenous Fistula Creation: Its Feasibility to Support Clinical Decision-Making

    Get PDF
    <div><h3>Introduction</h3><p>Inadequate flow enhancement on the one hand, and excessive flow enhancement on the other hand, remain frequent complications of arteriovenous fistula (AVF) creation, and hamper hemodialysis therapy in patients with end-stage renal disease. In an effort to reduce these, a patient-specific computational model, capable of predicting postoperative flow, has been developed. The purpose of this study was to determine the accuracy of the patient-specific model and to investigate its feasibility to support decision-making in AVF surgery.</p> <h3>Methods</h3><p>Patient-specific pulse wave propagation models were created for 25 patients awaiting AVF creation. Model input parameters were obtained from clinical measurements and literature. For every patient, a radiocephalic AVF, a brachiocephalic AVF, and a brachiobasilic AVF configuration were simulated and analyzed for their postoperative flow. The most distal configuration with a predicted flow between 400 and 1500 ml/min was considered the preferred location for AVF surgery. The suggestion of the model was compared to the choice of an experienced vascular surgeon. Furthermore, predicted flows were compared to measured postoperative flows.</p> <h3>Results</h3><p>Taken into account the confidence interval (25<sup>th</sup> and 75<sup>th</sup> percentile interval), overlap between predicted and measured postoperative flows was observed in 70% of the patients. Differentiation between upper and lower arm configuration was similar in 76% of the patients, whereas discrimination between two upper arm AVF configurations was more difficult. In 3 patients the surgeon created an upper arm AVF, while model based predictions allowed for lower arm AVF creation, thereby preserving proximal vessels. In one patient early thrombosis in a radiocephalic AVF was observed which might have been indicated by the low predicted postoperative flow.</p> <h3>Conclusions</h3><p>Postoperative flow can be predicted relatively accurately for multiple AVF configurations by using computational modeling. This model may therefore be considered a valuable additional tool in the preoperative work-up of patients awaiting AVF creation.</p> </div

    High Log-Scale Expansion of Functional Human Natural Killer Cells from Umbilical Cord Blood CD34-Positive Cells for Adoptive Cancer Immunotherapy

    Get PDF
    Immunotherapy based on natural killer (NK) cell infusions is a potential adjuvant treatment for many cancers. Such therapeutic application in humans requires large numbers of functional NK cells that have been selected and expanded using clinical grade protocols. We established an extremely efficient cytokine-based culture system for ex vivo expansion of NK cells from hematopoietic stem and progenitor cells from umbilical cord blood (UCB). Systematic refinement of this two-step system using a novel clinical grade medium resulted in a therapeutically applicable cell culture protocol. CD56+CD3− NK cell products could be routinely generated from freshly selected CD34+ UCB cells with a mean expansion of >15,000 fold and a nearly 100% purity. Moreover, our protocol has the capacity to produce more than 3-log NK cell expansion from frozen CD34+ UCB cells. These ex vivo-generated cell products contain NK cell subsets differentially expressing NKG2A and killer immunoglobulin-like receptors. Furthermore, UCB-derived CD56+ NK cells generated by our protocol uniformly express high levels of activating NKG2D and natural cytotoxicity receptors. Functional analysis showed that these ex vivo-generated NK cells efficiently target myeloid leukemia and melanoma tumor cell lines, and mediate cytolysis of primary leukemia cells at low NK-target ratios. Our culture system exemplifies a major breakthrough in producing pure NK cell products from limited numbers of CD34+ cells for cancer immunotherapy

    Precurved non-tunnelled catheters for haemodialysis are comparable in terms of infections and malfunction as compared to tunnelled catheters: A retrospective cohort study

    Get PDF
    Background: The main limitations of central venous catheters for haemodialysis access are infections and catheter malfunction. Our objective was to assess whether precurved non-tunnelled central venous catheters are comparable to tunnelled central venous catheters in terms of infection and catheter malfunction and to assess whether precurved non-tunnelled catheters are superior to straight catheters. Materials and methods: In this retrospective, observational cohort study, adult patients in whom a central venous catheter for haemodialysis was inserted between 2012 and 2016 were included. The primary endpoint was a combined endpoint consisting of the first occurrence of either an infection or catheter malfunction. The secondary endpoint was a combined endpoint of the removal of the central venous catheter due to either an infection or a catheter malfunction. Using multivariable analysis, cause-specific hazard ratios for endpoints were calculated for tunnelled catheter versus precurved non-tunnelled catheter, tunnelled catheter versus non-tunnelled catheter, and precurved versus straight nontunnelled catheter. Results: A total of 1603 patients were included. No difference in reaching the primary endpoint was seen between tunnelled catheters, compared to precurved non-tunnelled catheters (hazard ratio, 0.91; 95% confidence interval, 0.70– 1.19, p=0.48). Tunnelled catheters were removed less often, compared to precurved non-tunnelled catheters (hazard ratio, 0.65; 9

    Kliničke praktične smjernice za perioperacijsku i poslijeoperacijsku skrb o arterijsko-venskim fistulama i umetcima za hemodijalizu u odraslih

    Get PDF
    Krvožilni pristup omogućuje hemodijalizu koja spašava život. Stoga je nužna dobra funkcija krvožilnog pristupa koja omogućuje prikladan krvni protok radi uklanjanja tvari koje se u uremiji zadržavaju u krvi bolesnika, uz istodobno sniženje rizika od sustavne infekcije na najmanju moguću mjeru. Godine 2007. Europske smjernice najbolje prakse (engl. European Best Practice Guidelines – EBPG), prethodnice trenutačne Europske najbolje bubrežne prakse (engl. European Renal Best Practice – ERBP), donijele su nacrt skupine preporuka – vodiča pri donošenju odluka o upućivanju na pregled radi krvožilnog pristupa, o procjeni i nadzoru izbora pristupa te o postupcima kod komplikacija. (1) Otad su se znatno razvili ne samo dokazi na kojima se temelje ove preporuke nego i procesi nastajanja smjernica. (2) Kao odgovor na to, ERBP je ažurirao prethodno djelo u suradnji s raznim stručnjacima iz tog područja uključujući i predstavnike Društva za krvožilni pristup (engl. Vascular Access Society – VAS), kirurge za krvožilni pristup, radiologe, medicinske sestre za dijalizu, znanstvenike, bolesnike i one koji se za njih brinu. Nastojanje da se pridržavaju sve strože metodike izrade smjernica nalagalo je određena odricanja u pogledu područja obuhvata ovih smjernica. Posljedično, one ne „pokrivaju” baš sve iste teme kao njihova prethodna verzija. Neka su područja zajednička, a neka su arhivirana da bi ustupila mjesto novim pitanjima kojima su prednost dali i pružatelji zdravstvene skrbi i oni za koje se skrbi. Odvojeno su objavljene pojedinosti postupka izbora djelokruga problematike koju su smjernice obuhvatile. (3) Nastajanje ovih smjernica slijedilo je strog proces pregleda i procjene dokaza koji se temeljio na sustavnim pregledima rezultata kliničkih istraživanja te opservacijskih podataka gdje je to bilo potrebno. Strukturirani pristup slijedio je model sustava GRADE (hrv. stupanj), koji svakoj preporuci pripisuje stupanj s obzirom na sigurnost sveukupnih dokaza te snagu. (4) Gdje je to bilo primjereno skupina za izradu smjernica unijela je nestupnjevan savjet za kliničku praksu, a koji nije proistekao iz pregleda sustavnih dokaza. Kliničke praktične smjernice iz 2019. godine specifično pokrivaju peritransplantacijske i poslijetransplantacijske aspekte arterijsko-venskih (AV) fistula i umetaka (graftova). Drugi dio, koji je bio u nastajanju kada su ove smjernice išle u tisak, pokrit će aspekte izbora krvožilnog pristupa, prijeoperacijske procjene krvnih žila i središnje venske katetere. Unatoč nedostatku dokaza velike sigurnosti za većinu područja krvožilnih pristupa, ERBP se posvetio izradi smjernica velike kakvoće, dajući smjernicu gdje god je moguće, a popis preporuka za istraživanje ondje gdje se nije moglo uputiti smjernicom. Nadamo se da će ove smjernice i one planirane pomoći stručnoj zajednici pri donošenju odluka o postupcima, postupnicima i skrbi vezanima s krvožilnim pristupima, pomoći bolesnicima i onima koji se za njih brinu da steknu uvid u problematiku te olakšati zajedničko donošenje odluka u tom području

    Patient safety in dialysis access: education and research.

    No full text
    Today, a growing activity to improve patient safety in all domains of medicine is reality. This chapter deals with patient safety research in general, but is also about strategies to implement this evidence in the daily clinical work treating patients on dialysis. Good clinical research practice has been well established for some years. In the domain of dialysis access, further basic, clinical, epidemiological and health service research will be important to further improve patient safety as a whole
    corecore