25 research outputs found

    Is Radiation Superior to Indomethacin to Prevent Heterotopic Ossification in Acetabular Fractures?: A Systematic Review

    Get PDF
    Heterotopic ossification is a well-known complication after fixation of an acetabular fracture. Indomethacin and radiation therapy are used as prophylaxis to prevent heterotopic ossification. It is unclear, however, whether either is superior, although this may relate to lack of power in individual studies. To compare the effectiveness of indomethacin with the effectiveness of radiation therapy, we conducted a systematic review in which all published prospective studies were evaluated. We performed a literature search in PubMed®, MEDLINE®, EMBASE™, and the Cochrane Controlled Trial Register. The retrieved studies were analyzed and categorized according to the quality and validity score of Jadad et al. We found five appropriate prospective studies, describing 384 patients. Although the quality of the available studies made a proper meta-analysis inappropriate, the incidence of heterotopic ossification was significantly lower in patients treated with radiation than in patients receiving indomethacin (five of 160 versus 20 of 224, respectively). Until further information is available, we believe the evidence supports radiation therapy as the preferred method for preventing heterotopic ossification after operative treatment of acetabular fractures

    Have Surgery and Implant Modifications Been Associated With Reduction in Soft Tissue Complications in Transfemoral Bone-anchored Prostheses?

    Get PDF
    BackgroundThe most frequently occurring adverse events in individuals with a transfemoral amputation treated with a bone-anchored prosthesis are soft tissue infections and stoma-related complications. These soft tissue complications are believed to be influenced by surgical technique and implant design, but little is known about the effect of changes to treatment on these events.Questions/purposes(1) What is the result of surgical technique and implant modifications on the incidence of soft tissue infections and stoma-related complications in transfemoral bone-anchored prosthesis users, depending on whether they had a conventional stoma and a cobalt-chrome-molybdenum (CoCrMo) osseointegration implant (treatment period 2009 to 2013) or a shallower stoma and titanium osseointegration implant (2015 to 2018)? (2) What is the incidence of serious complications, such as bone or implant infection, aseptic loosening, intramedullary stem breakage, and periprosthetic fracture?MethodsBetween 2009 and 2013, we performed osseointegration implant surgery using a conventional surgical technique and a CoCrMo implant in 42 individuals who had a lower extremity amputation experiencing socket-related problems that resulted in limited prosthesis use. We considered all individuals treated with two-stage surgery with a standard press-fit transfemoral osseointegration implant as potentially eligible for inclusion. Based on this, 100% (42) were eligible, and 5% (two of 42) were excluded because they did not provide informed consent, leaving 95% (40 of 42) for analysis. Between 2015 and 2018, we treated 79 individuals with similar indications with osseointegration implant surgery, now also treating individuals with dysvascular amputations. We used an adapted surgical technique resulting in a shallower stoma combined with a titanium implant. Using the same eligibility criteria as for the first group, 51% (40 of 79) were eligible; 49% (39 of 79) were excluded because they were treated with transtibial amputation, a patient-specific implant, or single-stage surgery and 1% (one of 79) were lost before the 2-year follow-up interval, leaving 49% (39 of 79) for analysis. The period of 2013 to 2015 was a transitional period and was excluded from analysis in this study to keep groups reasonably comparable and to compare a historical approach with the present approach. Hence, we presented a comparative study of two study groups (defined by surgical technique and implant design) with standardized 2-year follow-up. The risk factors for adverse events were similar between groups, although individuals treated with the shallow stoma surgical technique and titanium implant potentially possessed an increased risk because of the inclusion of individuals with dysvascular amputation and the discontinuation of prolonged postoperative antibiotic prophylaxis. Outcomes studied were soft tissue infections and stoma-related complications (hypergranulation or keloid formation as well as stoma redundant tissue) and bone or implant infection, aseptic loosening, implant stem breakage, periprosthetic fracture, and death.ResultsPatients treated with the shallow stoma surgical technique and titanium implant experienced fewer soft tissue infections (13 versus 76 events, absolute risk 0.17 [95% CI 0.09 to 0.30] versus 0.93 [95% CI 0.60 to 1.45]; p &lt; 0.01), which were treated with less invasive measures, and fewer stoma redundant tissue events (0 versus five events, absolute risk 0 versus 0.06 [95% CI 0.03 to 0.14]) than patients treated with the conventional stoma surgical technique and CoCrMo implant. This was contrasted by an increased incidence of surgical site infections occurring between surgical stages 1 and 2, when no stoma was yet created, after the implementation of treatment changes (conventional surgery and CoCrMo implant versus shallow stoma surgery and titanium implant: one versus 11 events, absolute risk 0.01 [95% CI 0.00 to 0.08] versus 0.14 [95% CI 0.08 to 0.25]; p = 0.02). Patients treated with the shallow stoma surgical technique and titanium implant did not experience serious complications, although bone infections occurred (six events in 8% [three of 40] of patients) in the conventional surgery and CoCrMo implant group, all of which were successfully treated with implant retention.ConclusionAdaptations to surgical technique and newer implant designs, as well as learning curve and experience, have resulted in a reduced incidence and severity of soft tissue infections and stoma redundant tissue, contrasted by an increase in surgical site infections before stoma creation. Serious complications such as deep implant infection were infrequent in this 2-year follow-up period. We believe the benefits of these treatment modifications outweigh the disadvantages and currently advise surgeons to create a shallower stoma with a stable soft tissue envelope, combined with a titanium implant.Level of EvidenceLevel III, therapeutic study.</p

    Brugada syndrome during physical therapy: a case report

    Get PDF
    This case report describes about a young, male patient with persisting syncope during physical therapy for complex regional pain syndrome type 1 after metatarsal fractures

    Displaced midshaft fractures of the clavicle: non-operative treatment versus plate fixation (Sleutel-TRIAL). A multicentre randomised controlled trial

    Get PDF
    Contains fulltext : 96826.pdf (publisher's version ) (Open Access)BACKGROUND: The traditional view that the vast majority of midshaft clavicular fractures heal with good functional outcomes following non-operative treatment may be no longer valid for all midshaft clavicular fractures. Recent studies have presented a relatively high incidence of non-union and identified speciic limitations of the shoulder function in subgroups of patients with these injuries. AIM: A prospective, multicentre randomised controlled trial (RCT) will be conducted in 21 hospitals in the Netherlands, comparing fracture consolidation and shoulder function after either non-operative treatment with a sling or a plate fixation. METHODS/DESIGN: A total of 350 patients will be included, between 18 and 60 years of age, with a dislocated midshaft clavicular fracture. The primary outcome is the incidence of non-union, which will be determined with standardised X-rays (Antero-Posterior and 30 degrees caudocephalad view). Secondary outcome will be the functional outcome, measured using the Constant Score. Strength of the shoulder muscles will be measured with a handheld dynamometer (MicroFET2). Furthermore, the health-related Quality of Life score (ShortForm-36) and the Disabilities of Arm, Shoulder and Hand (DASH) Outcome Measure will be monitored as subjective parameters. Data on complications, bone union, cosmetic aspects and use of painkillers will be collected with follow-up questionnaires. The follow-up time will be two years. All patients will be monitored at regular intervals over the subsequent twelve months (two and six weeks, three months and one year). After two years an interview by telephone and a written survey will be performed to evaluate the two-year functional and mechanical outcomes. All data will be analysed on an intention-to-treat basis, using univariate and multivariate analyses. DISCUSSION: This trial will provide level-1 evidence for the comparison of consolidation and functional outcome between two standardised treatment options for dislocated midshaft clavicular fractures. The gathered data may support the development of a clinical guideline for treatment of clavicular fractures. TRIAL REGISTRATION: Netherlands National Trial Register NTR2399

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Gasoline contact burns after a car accident.

    No full text
    Contains fulltext : 53432.pdf (publisher's version ) (Closed access

    Safety of osseointegrated implants for transfemoral amputees : a two-center prospective cohort study

    No full text
    Background: Osseointegrated implants are an alternative for prosthetic attachment for individuals unable to wear a socket following an amputation. The concept of an integrated metal implant communicating with the external environment raises substantial concern about the risk of ascending infection. We report on the safety of press-fit osseointegrated implants currently used in Australia and the Netherlands. Methods: We prospectively recorded all adverse events in all patients with transfemoral amputation who were managed with an osseointegration implant system between 2009 and 2013 at two centers. The procedure was performed in two stages. A customized porous-coated implant was placed in the first stage, and a stoma was created in the second. Adverse events were categorized according to type (infection or “other”) and severity. Infections were classified according to four grades of severity based on clinical and radiographic findings: (1) low-grade soft-tissue infection, (2) high-grade soft-tissue infection, (3) bone infection, and (4) septic implant failure. Results: Eighty-six patients (ninety-one implants), twenty-five to eighty-one years of age, were included in the study and followed for a median of thirty-four months (range, twenty-four to seventy-one months). Thirty-one patients had an uneventful course with no complications; twenty-nine developed infection (all grade 1 or 2); and twenty-six did not develop infection but had one or more other complications requiring intervention, including stoma hypergranulation (seventeen patients), soft-tissue redundancy (fourteen), proximal femoral fracture (three), inadequate osseointegration leading to implant replacement (one), implant breakage (two), and breakage of the pin used as a fail-safe mechanism (twenty-five). Conclusions: Mild infection and irritation of the soft tissue in the skin-penetration area are common in transfemoral amputees who have an osseointegrated implant. These complications were successfully managed with simple measures. Severe infections resulting in septic implant loosening are rare.10 page(s
    corecore