17 research outputs found

    Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report

    Get PDF
    This study aimed to determine the retest variability of quantitative fundus autofluorescence (QAF) in patients with and without age-related macular degeneration (AMD) and evaluate the predictive value of patient reliability indices on retest reliability. A total of 132 eyes from 68 patients were examined, including healthy individuals and those with various stages of AMD. Duplicate QAF imaging was conducted at baseline and 2 weeks later across six study sites. Intraclass correlation (ICC) analysis was used to evaluate the consistency of imaging, and mean opinion scores (MOS) of image quality were generated by two researchers. The contribution of MOS and other factors to retest variation was assessed using mixed-effect linear models. Additionally, a Random Forest Regressor was trained to evaluate the extent to which manual image grading of image quality could be replaced by automated assessment (inferred MOS). The results showed that ICC values were high for all QAF images, with slightly lower values in AMD-affected eyes. The average inter-day ICC was found to be 0.77 for QAF segments within the QAF8 ring and 0.74 for peripheral segments. Image quality was predicted with a mean absolute error of 0.27 on a 5-point scale, and of all evaluated reliability indices, MOS/inferred MOS proved most important. The findings suggest that QAF allows for reliable testing of autofluorescence levels at the posterior pole in patients with AMD in a multicenter, multioperator setting. Patient reliability indices could serve as eligibility criteria for clinical trials, helping identify patients with adequate retest reliability

    Instrumental Activities of Daily Living Tools in Very-Low Vision: Ready for Use in Trials?

    No full text
    Traditional endpoints assessing visual function are limited by their responsiveness to interventions restoring or maintaining vision. An alternative concept is assessing instrumental activities of daily living (IADL). Herein, we review all available vision-specific IADL instruments relevant for vision restoration trials and report data for the most promising instrument. Six relevant instruments exist: The Low Vision Functional Status Evaluation (LVFSE), Timed IADL (TIADL), Melbourne Low-Vision Activities of Daily Living Index (MLVAI), Assessment of Disability Related to Vision (ADREV), Functional Low-Vision Observer Rated Assessment (FLORA), and Very Low Vision IADL (IADL-VLV). Both internal consistency and test-retest data were available for the LVFSE, MLVAI, and IADL-VLV. In a sample from a low-vision clinic (n = 51; age 57 ± 16 years), we report additional validation data on the IVI-VLV including test–retest reliability (intraclass correlation coefficient 0.981 [0.961; 0.991]). The LVSFE was noticeably less reliable than the MLVAI and the IADL-VLV. Content and construct validity data were available for the LVFSE, TIADL, MLVAI, ADREV, and IADL-VLV, but only the MLVAI and IADL-VLV were developed for an ultra-low vision context. Ceiling effects were present across instruments. Thus, of all appropriate IADL instruments related to vision, the IADL-VLV and MLVAI best meet existing requirements for use in vision restoration trials, e.g., in gene therapies or visual prostheses in inherited retinal diseases, but require further validation

    Automated thresholding algorithms outperform manual thresholding in macular optical coherence tomography angiography image analysis.

    No full text
    INTRODUCTION:For quantification of Optical Coherence Tomography Angiography (OCTA) images, Vessel Density (VD) and Vessel Skeleton Density (VSD) are well established parameters and different algorithms are in use for their calculation. However, comparability, reliability and ability to discriminate healthy and impaired macular perfusion of different algorithms are unclear, yet, of potential high clinical relevance. Hence, we assessed comparability and test-retest reliability of the most common approaches. MATERIALS AND METHODS:Two consecutive 3×3mm OCTA en face images of the superficial and deep retinal layer were acquired with swept-source OCTA. VD and VSD were calculated with manual thresholding and six automated thresholding algorithms (Huang, Li, Otsu, Moments, Mean, Percentile) using ImageJ and compared in terms of intra-class correlation coefficients, measurement differences and repeatability coefficients. Receiver operating characteristic analyses (healthy vs. macular pathology) were performed and Area Under the Curve (AUC) values were calculated. RESULTS:Twenty-six eyes (8 female, mean age: 47 years) of 15 patients were included (thereof 15 eyes with macular pathology). Binarization thresholds, VD and VSD differed significantly between the algorithms and compared to manual thresholding (p < 0.0001). Inter-measurement differences did not differ significantly between patients with healthy versus pathologic maculae (p ≥ 0.685). Reproducibility was higher for the automated algorithms compared to manual thresholding on all measures of reproducibility assessed. AUC was significantly higher for the Mean algorithm compared to the manual approach with respect to the superficial retinal layer. CONCLUSIONS:Automated thresholding algorithms yield a higher reproducibility of OCTA parameters and allow for a more sensitive diagnosis of macular pathology. However, different algorithms are not interchangeable nor results readily comparable. Especially the Mean algorithm should be investigated in further detail. Automated thresholding algorithms are preferable but more standardization is needed for clinical use

    Knowledge about age-related eye diseases in the general population in Germany

    No full text
    Abstract Background With a rising prevalence of age-related eye diseases, prevention and early diagnosis of these conditions are key goals of public eye health. Disease-related knowledge in the general public supports these goals but there is little data available. Thus, we have assessed knowledge of cataract, glaucoma, age-related macular degeneration (AMD) and diabetic eye disease in the German adult general population in a cross-sectional study and identified target groups for health education interventions. Methods Knowledge assessment content was identified based on a literature review, expert input, and a list of items was generated after a qualitative selection process. The resulting 16-item instrument (4 items per condition) was administered to 1,008 participants from a survey panel, demographically representative of the adult German population. Test properties were evaluated based on a Rasch model and multiple correspondence analysis (MCA). Binary-logistic regression analysis was performed to investigate associations with age, sex, education level, employment status, marital status, income, reported health status, visual difficulties, and recent general practitioner (GP) and ophthalmologist consultations. Results Replies were correct for a median of 9 out of 16 (range 2 – 16) items, which differed between conditions (p < 0.0001). Most responses were correct for cataract items (median: 3 / 4) and least were correct for AMD items (median: 2 / 4). 27%, 9%, 1% and 19% of respondents replied correctly to all cataract, glaucoma, AMD and diabetic eye disease-related items, respectively. Rasch analysis suggested an adequate targeting of items and in MCA, no evidence of multidimensionality was present. Older age, being retired, decreased general health and recent GP or ophthalmology consultations were significantly associated with more knowledge about common eye conditions (p ≤ 0.005). GP or ophthalmology consultations remained significant in a multivariable model (p ≤ 0.011). Conclusions Knowledge gaps regarding eye health are considerable in the German general population and should therefore be addressed in educational interventions targeting the public. Special attention when designing such campaigns needs to be paid to infrequent users of the healthcare system. Knowledge of AMD seems to be poorer compared to other eye conditions

    Patient-reported vision impairment in low luminance predicts multiple falls

    No full text
    Abstract Background Visual impairment is an independent risk factor for falling. Whether this extends to patient-reported visual difficulties has not been assessed to date. We have evaluated whether patient-reported visual difficulties in low-contrast and low luminance situations are a risk factor for falls and concerns about falling. Methods Baseline assessments in outpatients with varying degrees of visual impairment aged ≥ 60 years included the Vision Impairment in Low Luminance (VILL) questionnaire and socio-demographic data; prospective follow-up assessments included falls over 12 months, the Falls Efficacy Scale (FES-I) and the VILL. The VILL was scored using Rasch models, and the FES-I was categorized following published guidelines. Associations were investigated using logistic regression analysis, controlling for age, visual acuity and known risk factors of falling. Results We included 112 participants (74 women, mean age 70 ± 7 years). Twenty-seven participants recalled any falls and eleven recalled multiple falls at follow-up. Higher VILL reading subscale and mobility subscale scores at baseline were significantly associated with reporting less multiple falls at follow-up (OR 0.559 [0.333–0.936], p = 0.027 and OR 0.595 [0.377–0.940], p = 0.026). VILL scores were significantly associated with concerns about falling (high versus low: p ≤ 0.004, reading, mobility and emotional subscales; high versus moderate: p = 0.004, emotional subscale). Conclusions Patient-reported visual difficulties under low illumination and in low-contrast conditions are predictive of multiple falls in the future, have an additional predictive value over established risk scores, and are associated with concerns to fall. Current fall risk assessments may benefit from the inclusion of such assessments, e.g. the VILL questionnaire

    Modifications in ocular microperfusion after transcatheter aortic valve implantation

    No full text
    Abstract Cerebral embolization is a known complication of transcatheter aortic valve implantation (TAVI) but the effect of the procedure on the ocular perfusion is currently unclear. Thus, we investigated post-procedural morphologic and perfusion changes of the retina and choroid, using optical coherence tomography angiography (OCTA) and color fundus photography (CFP) in a prospective cohort study. Ophthalmic examinations were conducted pre- and post-TAVI. OCTA images were analyzed quantitatively based on vessel density and skeleton density of the superficial and deep retinal plexus as well as the signal intensity and flow deficits in the choriocapillaris. CFP images were assessed for presence of acute retinal ischemia, optic nerve swelling, vessel emboli, hemorrhages and cotton wool spots. Data was analyzed using linear mixed models. Twenty patients (9 women; 11 men) at a mean age of 81 ± 6 years were included. Pre- and post-interventional ocular imaging data were available for 32 eyes. The analysis revealed a significant impairment of the choriocapillaris perfusion after TAVI with an increased proportion of flow deficits (p = 0.044). When controlling for blood pressure, the average size of choriocapillaris flow voids was significantly increased (systolic and diastolic, p = 0.039 and 0.029). Qualitatively, focal areas of retinal ischemia were detected on OCTA in 33% of participants. Silent emboli or cotton wool spots were identified on CFP in 21%. Our findings indicate a reduced choroidal perfusion as well as areas of retinal ischemia and embolization in a considerable proportion of patients following TAVI. Pending confirmation in a larger sample, these complications merit monitoring as well as inclusion in consent procedures for TAVI

    Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report

    No full text
    &lt;p&gt;This study aimed to determine the retest variability of quantitative fundus autofluorescence (QAF) in patients with and without age-related macular degeneration (AMD) and evaluate the predictive value of patient reliability indices on retest reliability. A total of 132 eyes from 68 patients were examined, including healthy individuals and those with various stages of AMD. Duplicate QAF imaging was conducted at baseline and 2 weeks later across six study sites. Intraclass correlation (ICC) analysis was used to evaluate the consistency of imaging, and mean opinion scores (MOS) of image quality were generated by two researchers. The contribution of MOS and other factors to retest variation was assessed using mixed-effect linear models. Additionally, a Random Forest Regressor was trained to evaluate the extent to which manual image grading of image quality could be replaced by automated assessment (inferred MOS). The results showed that ICC values were high for all QAF images, with slightly lower values in AMD-affected eyes. The average inter-day ICC was found to be 0.77 for QAF segments within the QAF8 ring and 0.74 for peripheral segments. Image quality was predicted with a mean absolute error of 0.27 on a 5-point scale, and of all evaluated reliability indices, MOS/inferred MOS proved most important. The findings suggest that QAF allows for reliable testing of autofluorescence levels at the posterior pole in patients with AMD in a multicenter, multioperator setting. Patient reliability indices could serve as eligibility criteria for clinical trials, helping identify patients with adequate retest reliability.&lt;/p&gt

    Retest variability and patient reliability indices of quantitative fundus autofluorescence in age-related macular degeneration: a MACUSTAR study report

    No full text
    Abstract This study aimed to determine the retest variability of quantitative fundus autofluorescence (QAF) in patients with and without age-related macular degeneration (AMD) and evaluate the predictive value of patient reliability indices on retest reliability. A total of 132 eyes from 68 patients were examined, including healthy individuals and those with various stages of AMD. Duplicate QAF imaging was conducted at baseline and 2 weeks later across six study sites. Intraclass correlation (ICC) analysis was used to evaluate the consistency of imaging, and mean opinion scores (MOS) of image quality were generated by two researchers. The contribution of MOS and other factors to retest variation was assessed using mixed-effect linear models. Additionally, a Random Forest Regressor was trained to evaluate the extent to which manual image grading of image quality could be replaced by automated assessment (inferred MOS). The results showed that ICC values were high for all QAF images, with slightly lower values in AMD-affected eyes. The average inter-day ICC was found to be 0.77 for QAF segments within the QAF8 ring and 0.74 for peripheral segments. Image quality was predicted with a mean absolute error of 0.27 on a 5-point scale, and of all evaluated reliability indices, MOS/inferred MOS proved most important. The findings suggest that QAF allows for reliable testing of autofluorescence levels at the posterior pole in patients with AMD in a multicenter, multioperator setting. Patient reliability indices could serve as eligibility criteria for clinical trials, helping identify patients with adequate retest reliability
    corecore