1,556 research outputs found

    Implications of the X-ray Variability for the Mass of MCG-6-30-15

    Get PDF
    The bright Seyfert 1 galaxy \mcg shows large variability on a variety of time scales. We study the \aproxlt 3 day time scale variability using a set of simultaneous archival observations that were obtained from \rxte and the {\it Advanced Satellite for Cosmology and Astrophysics} (\asca). The \rxte\ observations span nearly 10610^6 sec and indicate that the X-ray Fourier Power Spectral Density has an rms variability of 16%, is flat from approximately 10^{-6} - 10^{-5} Hz, and then steepens into a power law fα\propto f^{-\alpha} with \alpha\aproxgt 1. A further steepening to α2\alpha \approx 2 occurs between 10^{-4}-10^{-3} Hz. The shape and rms amplitude are comparable to what has been observed in \ngc and \cyg, albeit with break frequencies that differ by a factor of 10^{-2} and 10^{4}, respectively. If the break frequencies are indicative of the central black hole mass, then this mass may be as low as 106M10^6 {\rm M}_\odot. An upper limit of 2\sim 2 ks for the relative lag between the 0.5-2 keV \asca band compared to the 8-15 keV \rxte band was also found. Again by analogy with \ngc and \cyg, this limit is consistent with a relatively low central black hole mass.Comment: 5 pages, 3 figures, LaTeX, uses emulateapj.sty and apjfonts.sty, revised version, accepted for publication in ApJ Letter

    Distribution of major anions and trace elements in the unsaturated zone at Franklin Lake Playa, California, USA

    Get PDF
    The composition of surficial salts formed near dry and drying saline lakes are partly the product of processes active in the unsaturated zone between the ground surface and the water table. These processes were investigated by determining the abundance of water-extractable solutes in sediment from the ground surface to the water table (~2.8 m) beneath Franklin Lake playa, California. Accumulation of solutes in the sediment is attributed to evaporation of aqueous solutions transported upward from the water table through the capillary fringe to an evaporation font that is currently 20-30 cm below the ground surface. Salts in the sediment from 0 to 20 cm depth are depleted in chloride and enriched in carbonate relative to deeper samples. Chloride depletion is most likely a product of selective dissolution by vertical recharge. The entire unsaturated zone contains greater amounts of carbonate than expected for evaporation of ground water and is best explained by preferential dissolution of more soluble salts in recharging precipitation but may also reflect the assimilation of CO2 as carbonate minerals precipitate. Variations in the concentrations of arsenic, molybdenum, tungsten, and uranium in the water-soluble fraction of the sediment are complex and suggest unique geochemical controls on the abundance of each element. The distribution of these trace element abundances indicates the arsenic is the element most likely to accumulate in near-surface salts

    Association analysis of \u3ci\u3ePRNP\u3c/i\u3e gene region with chronic wasting disease in Rocky Mountain elk

    Get PDF
    Background: Chronic wasting disease (CWD) is a transmissible spongiform encephalopathy (TSE) of cervids including white-tailed (Odocoileus virginianus) and mule deer (Odocoileus hemionus), Rocky Mountain elk (Cervus elaphus nelsoni), and moose (Alces alces). A leucine variant at position 132 (132L) in prion protein of Rocky Mountain elk confers a long incubation time with CWD, but not complete resistance. However, variants in regulatory regions outside the open reading frame of PRNP have been associated with varying degrees of susceptibility to prion disease in other species, and some variants have been observed in similar regions of Rocky Mountain elk PRNP. Thus, additional genetic variants might provide increased protection, either alone or in combination with 132L. Findings: This study provided genomic sequence of all exons for PRNP of Rocky Mountain elk. Many functional sites in and around the PRNP gene region were sequenced, and this report approximately doubled (to 75) the number of known variants in this region. A haplotype-tagging approach was used to reduce the number of genetic variants required to survey this variation in the PRNP gene region of 559 Rocky Mountain elk. Eight haplotypes were observed with frequencies over 1.0%, and one haplotype was present at 71.2% frequency, reflecting limited genetic diversity in the PRNP gene region. Conclusions: The presence of 132L cut odds of CWD by more than half (Odds Ratio = 0.43; P = 0.0031), which was similar to a previous report. However after accounting for 132L, no association with CWD was found for any additional variants in the PRNP region (P \u3e 0.05)

    Innovative Development of a Cross-Center Timeline Planning Tool

    Get PDF
    The Payload Operations Integration Center (POIC) at Marshall Space Flight Center (MSFC) is the United States focal point to support operations controllers and payload developers conducting payload science operations for the National Aeronautics and Space Administration (NASA) aboard the International Space Station (ISS). Some of the key functions are planning, coordination and scheduling of science activities. This effort occurs in coordination with other NASA centers, international partners, and payload developers. The ability to efficiently plan and re-plan in response to change is critical to the flight planning teams. Additionally, in Fall 2017, NASA will increase its ability to perform payload science operations aboard the ISS with a fourth crew member. In order to support this, there will be an increasing need to quickly plan and schedule more activities. In the past, it was cumbersome and time-consuming to consolidate copious amounts of planning and change request data from various sources. Planners would summarize information from the Johnson Space Center (JSC) Operations Planning Timeline Integration System (OPTIMIS) and manually integrate it with other data in order to produce a Timeline Planning Summary (TPS). This lengthy process of updating static documents while planning and re-planning was cumbersome, introduced human error, and was inflexible to last minute changes. There was a need for a dynamic, more efficient, less erroneous, and more concise way of building a report that could be readily updated as fast as payload science plans change

    Innovative Development of a Cross-Center Timeline Planning Tool

    Get PDF
    The Payload Operations Integration Center (POIC) at Marshall Space Flight Center (MSFC) supports planning, coordination and scheduling of science activities for the International Space Station (ISS) in coordination with other NASA centers, international partners, and payload developers. The ability to efficiently plan and re-plan in response to change is critical to the flight planning teams. With the achievement of supporting a fourth crew member aboard the ISS and an increasing amount of payload science activities, came the need for a dynamic, more efficient way of building timeline planning reports that could be readily updated as fast as payload science plans could change. This paper addresses software architecture considerations in the successful cross-center development of an automated planning tool with multiple data sources. It also discusses the practical implementation of a time-boxed, hybrid Agile Software Development (ASD) approach to deliver customer-driven value despite changing requirements with respect to low-Earth orbit operational planning activities. The goal of this paper is to open discussion with members of the international community and trade effective strategies for cross-center architectural and customer-developer driven collaborations, to support increasing utilization of planning and conducting science activities in space

    Detection of Children/Youth With Fetal Alcohol Spectrum Disorder Through Eye Movement, Psychometric, and Neuroimaging Data

    Get PDF
    Background: Fetal alcohol spectrum disorders (FASD) is one of the most common causes of developmental disabilities and neurobehavioral deficits. Despite the high-prevalence of FASD, the current diagnostic process is challenging and time- and money- consuming, with underreported profiles of the neurocognitive and neurobehavioral impairments because of limited clinical capacity. We assessed children/youth with FASD from a multimodal perspective and developed a high-performing, low-cost screening protocol using a machine learning framework.Methods and Findings: Participants with FASD and age-matched typically developing controls completed up to six assessments, including saccadic eye movement tasks (prosaccade, antisaccade, and memory-guided saccade), free viewing of videos, psychometric tests, and neuroimaging of the corpus callosum. We comparatively investigated new machine learning methods applied to these data, toward the acquisition of a quantitative signature of the neurodevelopmental deficits, and the development of an objective, high-throughput screening tool to identify children/youth with FASD. Our method provides a comprehensive profile of distinct measures in domains including sensorimotor and visuospatial control, visual perception, attention, inhibition, working memory, academic functions, and brain structure. We also showed that a combination of four to six assessments yields the best FASD vs. control classification accuracy; however, this protocol is expensive and time consuming. We conducted a cost/benefit analysis of the six assessments and developed a high-performing, low-cost screening protocol based on a subset of eye movement and psychometric tests that approached the best result under a range of constraints (time, cost, participant age, required administration, and access to neuroimaging facility). Using insights from the theory of value of information, we proposed an optimal annual screening procedure for children at risk of FASD.Conclusions: We developed a high-capacity, low-cost screening procedure under constrains, with high expected monetary benefit, substantial impact of the referral and diagnostic process, and expected maximized long-term benefits to the tested individuals and to society. This annual screening procedure for children/youth at risk of FASD can be easily and widely deployed for early identification, potentially leading to earlier intervention and treatment. This is crucial for neurodevelopmental disorders, to mitigate the severity of the disorder and/or frequency of secondary comorbidities

    The Mid-Infrared Emission of M87

    Get PDF
    We discuss Subaru and Spitzer Space Telescope imaging and spectroscopy of M87 in the mid-infrared from 5-35 um. These observations allow us to investigate mid-IR emission mechanisms in the core of M87 and to establish that the flaring, variable jet component HST-1 is not a major contributor to the mid-IR flux. The Spitzer data include a high signal-to-noise 15-35 μ\mum spectrum of the knot A/B complex in the jet, which is consistent with synchrotron emission. However, a synchrotron model cannot account for the observed {\it nuclear} spectrum, even when contributions from the jet, necessary due to the degrading of resolution with wavelength, are included. The Spitzer data show a clear excess in the spectrum of the nucleus at wavelengths longer than 25 um, which we model as thermal emission from cool dust at a characteristic temperature of 55 \pm 10 K, with an IR luminosity \sim 10^{39} {\rm ~erg ~s^{-1}}. Given Spitzer's few-arcsecond angular resolution, the dust seen in the nuclear spectrum could be located anywhere within ~5'' (390 pc) of the nucleus. In any case, the ratio of AGN thermal to bolometric luminosity indicates that M87 does not contain the IR-bright torus that classical unified AGN schemes invoke. However, this result is consistent with theoretical predictions for low-luminosity AGNsComment: 9 pages, 7 figures, ApJ, in pres

    A Better Index of Body Adiposity

    Get PDF
    Obesity is a growing problem in the United States and throughout the world. It is a risk factor for many chronic diseases. The BMI has been used to assess body fat for almost 200 years. BMI is known to be of limited accuracy, and is different for males and females with similar %body adiposity. Here, we define an alternative parameter, the body adiposity index (BAI = ((hip circumference)/((height)1.5)–18)). The BAI can be used to reflect %body fat for adult men and women of differing ethnicities without numerical correction. We used a population study, the “BetaGene” study, to develop the new index of body adiposity. %Body fat, as measured by the dual-energy X-ray absorptiometry (DXA), was used as a “gold standard” for validation. Hip circumference (R = 0.602) and height (R = −0.524) are strongly correlated with %body fat and therefore chosen as principal anthropometric measures on which we base BAI. The BAI measure was validated in the “Triglyceride and Cardiovascular Risk in African-Americans (TARA)” study of African Americans. Correlation between DXA-derived %adiposity and the BAI was R = 0.85 for TARA with a concordance of C_b = 0.95. BAI can be measured without weighing, which may render it useful in settings where measuring accurate body weight is problematic. In summary, we have defined a new parameter, the BAI, which can be calculated from hip circumference and height only. It can be used in the clinical setting even in remote locations with very limited access to reliable scales. The BAI estimates %adiposity directly

    Lrg1 Regulates β (1, 3)-Glucan Masking in Candida albicans through the Cek1 MAP Kinase Pathway

    Get PDF
    Candida albicans is among the most prevalent opportunistic human fungal pathogens. The ability to mask the immunogenic polysaccharide β (1,3)-glucan from immune detection via a layer of mannosylated proteins is a key virulence factor of C. albicans. We previously reported that hyperactivation of the Cek1 mitogen-activated protein (MAP) kinase pathway promotes β (1,3)-glucan exposure. In this communication, we report a novel upstream regulator of Cek1 activation and characterize the impact of Cek1 activity on fungal virulence. Lrg1 encodes a GTPase-activating protein (GAP) that has been suggested to inhibit the GTPase Rho1. We found that disruption of LRG1 causes Cek1 hyperactivation and β (1,3)-glucan unmasking. However, when GTPase activation was measured for a panel of GTPases, the lrg1ΔΔ mutant exhibited increased activation of Cdc42 and Ras1 but not Rho1 or Rac1. Unmasking and Cek1 activation in the lrg1ΔΔ mutant can be blocked by inhibition of the Ste11 MAP kinase kinase kinase (MAPKKK), indicating that the lrg1ΔΔ mutant acts through the canonical Cek1 MAP kinase cascade. In order to determine how Cek1 hyperactivation specifically impacts virulence, a doxycycline-repressible hyperactive STE11ΔN467 allele was expressed in C. albicans. In the absence of doxycycline, this allele overexpressed STE11ΔN467, which induced production of proinflammatory tumor necrosis factor alpha (TNF-α) from murine macrophages. This in vitrophenotype correlates with decreased colonization and virulence in a mouse model of systemic infection. The mechanism by which Ste11ΔN467 causes unmasking was explored with RNA sequencing (RNA-Seq) analysis. Overexpression of Ste11ΔN467 caused upregulation of the Cph1 transcription factor and of a group of cell wall-modifying proteins which are predicted to impact cell wall architecture

    The Radio Variability of the Gravitational Lens PMN J1838-3427

    Full text link
    We present the results of a radio variability study of the gravitational lens PMN J1838-3427. Our motivation was to determine the Hubble constant by measuring the time delay between variations of the two quasar images. We monitored the system for 4 months (approximately 5 times longer than the expected delay) using the Australia Telescope Compact Array at 9 GHz. Although both images were variable on a time scale of a few days, no correlated intrinsic variability could be identified, and therefore no time delay could be measured. Notably, the fractional variation of the fainter image (8%) was greater than that of the brighter image (4%), whereas lensed images of a point source would have the same fractional variation. This effect can be explained, at least in part, as the refractive scintillation of both images due to the turbulent interstellar medium of the Galaxy.Comment: To appear in AJ (8 pages, including 4 figures
    corecore