3,914 research outputs found

    A Coproantigen Diagnostic Test for Strongyloides Infection

    Get PDF
    Accurate diagnosis of infection with the parasite Strongyloides stercoralis is hampered by the low concentration of larvae in stool, rendering parasitological diagnosis insensitive. Even if the more sensitive agar plate culture method is used repeated stool sampling is necessary to achieve satisfactory sensitivity. In this manuscript we describe the development of a coproantigen ELISA for diagnosis of infection. Polyclonal rabbit antiserum was raised against Strongyloides ratti excretory/secretory (E/S) antigen and utilized to develop an antigen capture ELISA. The assay enabled detection of subpatent rodent S. ratti and human S. stercoralis infection. No cross-reactivity was observed with purified E/S from Schistosoma japonicum, the hookworms Ancylostoma caninum, A. ceylanicum, nor with fecal samples collected from rodents harboring Trichuris muris or S. mansoni infection. Strongyloides coproantigens that appear stable when frozen as formalin-extracted fecal supernatants stored at −20°C remained positive up to 270 days of storage, whereas supernatants stored at 4°C tested negative. These results indicate that diagnosis of human strongyloidiasis by detection of coproantigen is an approach worthy of further development

    A comparison of pilot-scale supersonic direct steam injection to conventional steam infusion and tubular heating systems for the heat treatment of protein-enriched skim milk-based beverages

    Get PDF
    peer-reviewedDirect supersonic steam injection, direct steam infusion, and indirect tubular heating were each applied to protein-enriched skim milk-based beverages with 4, 6 and 8% (w/w) total protein, and the effect of final heat temperature on the physical properties of these beverages was investigated. Supersonic steam injection resulted in significantly lower levels of denaturation of β-lactoglobulin (34.5%), compared to both infusion (76.3%) and tubular (97.1%) heating technologies. Viscosity, particle size and accelerated physical stability of formulations did not differ significantly between the heating technologies, while noticeable colour differences due to heat treatment (mainly attributed to increasing b* value) were observed, particularly for tubular heating. Overall, the extent of protein denaturation in high-protein dairy products was significantly influenced by the particular heating technology applied. The application of supersonic steam injection technology, with rapid heating and high shear characteristics, may enable differenciated product characteristics for ready-to-drink ambient-delivery high-protein dairy beverages. Industrial relevance: The design and application of novel direct supersonic steam injection technology was comprehensively studied and found to provide significant benefits over direct steam infusion and indirect tubular heating technologies for skim milk-based protein beverages. This type of injection heating system resulted in heat-treated formulations with lower levels of denatured whey proteins, compared to tubular and infusion heating, offering an alternative opportunity to the industry in terms of producing shelf-stable dairy protein beverages

    The effect of Holstein-Friesian genotype and feeding system on selected performance parameters of dairy cows on grass-based systems of milk production in Ireland

    Get PDF
    End of project reportThe overall objective of this project was to assess, the effect of strain of Holstein-Friesian dairy cow, pasture-based feed system (FS) and their interaction on animal performance in terms of milk productivity and lactation profile, body weight (BW), body condition score (BCS), feed intake and energy balance (EB), reproductive performance and overall economic profitability

    Advanced Ultrasonic Inspection of Thick-Section Composite Structures for In-Field Asset Maintenance

    Get PDF
    An investigation into the inspection capabilities of in-field advanced ultrasound detection for use on ultra-thick (20 to 100 mm) glass fibre-reinforced polyester composites is presented. Plates were manufactured using custom moulding techniques, such that delamination flaws were created at calibrated depths. The full matrix capture technique with an on-board total focussing method was used to detect flaws scanned by a 0.5 MHz linear array probe. Flaw through-thickness dimensions were altered to assess the threshold for crack face separation at which delaminations could be identified. Furthermore, part thickness and in-plane flaw dimensions were varied to identify the inspection capability limitations of advanced ultrasonics for thick composites. The results presented in this study demonstrate an inverse relationship between the ability to find delaminations and plate thicknesses, with inspections successful at depths up to 74 mm. When the delamination thickness exhibited surface-to-surface contact, the inspection capability was reduced to 35 mm. There was an exponential decay relationship between the accuracy of the flaw depth measurement and plate thickness, likely due to the necessity of low probe frequencies. The effective inspection depth was determined to be in the range of 1 to 20 times the wavelength. It is speculated that the accuracy of measurements could be improved using probes with novel coupling solutions, and detectors with optimised signal processing/filtration algorithms

    Protein kinase activity is associated with CD63 in melanoma cells

    Get PDF
    BACKGROUND: The tetraspan protein CD63, originally described as a stage-specific melanoma antigen but also present in a number of normal cells, regulates melanoma cell growth in nude mice, motility in serum containing media, and adhesion to several extracellular matrix proteins. CD63 has been reported to associate with β1 and β2 integrins, but the mechanism of signal transduction by CD63 is not clear. This study examined whether CD63 is associated with protein kinase and can transmit signals in melanoma cells. METHODS: Immunoprecipitation and radiolabeling were used to test for association of protein kinase activity with CD63. Adhesion of cells to monoclonal antibodies immobilized to microtiter plates was used to examine the ability of CD63 to transmit signals. RESULTS: CD63 was capable of transmitting a signal in melanoma cells that required extracellular calcium. In the absence of extracellular calcium at the time of binding to the CD63 mAb, the cell was no longer responsive to stimulation by CD63. Immunoprecipitation studies demonstrated protein kinase activity associated with CD63, and phosphoamino acid analysis revealed that most of this protein kinase activity was due to serine kinase activity. CONCLUSION: The current study suggests that serine protein kinase activity associated with CD63 may play a role in signaling by CD63 in melanoma cells

    Effect of Glass Fibre Sizing on the Interfacial Properties of Composites Produced using In-Situ Polymerised Polyamide-6 Transfer Moulding

    Get PDF
    The fibre-matrix interfacial properties of glass-fibre/polyamide-6 (GF/PA-6) composites produced by thermoplastic resin transfer moulding (TP-RTM) were investigated. Two different fibre sizings were compared, a specially-developed novel reactive fibre sizing and a standard silane glass fibre sizing. Scanning electron microscopy, atomic force microscopy and a number of mass-loss techniques were employed to study the form, distribution, quantity and degradation temperature of the fibre sizings. Activated PA-6 monomer precursor materials with viscosities of ∼10 mPa s were injected into the glass-fibre fabrics, contained between heated press platens, and polymerisation occurred in-situ within several minutes. Glass-fabric laminates with fibre volume fractions of ∼53% and low void content were produced at a pressure of ∼4 bar, with the low viscosity of the monomer negating the need for expensive high-pressure injection. Similar quality between the laminates was demonstrated by measuring density, thickness, fibre volume fraction, void content and fibre bundle distribution. Transverse mechanical properties of the composites reinforced with the novel reactive sizing were 20–28% higher than those with the standard fibre sizings, demonstrating improved fibre-matrix interfacial properties. Average mode I fracture toughness was also measured to be 10–30% higher than with the standard fibre sizing. Scanning electron microscopy and 3D depth composition were used to investigate fracture surfaces and determine the surface roughness. The novel reactive fibre sizing resulted in improved fibre-matrix adhesion and improved fracture toughness

    Left ventricular echocardiographic and histologic changes: Impact of chronic unloading by an implantable ventricular assist device

    Get PDF
    AbstractObjectives. We studied the effects of chronic left ventricular unloading by a ventricular assist device and assessed left ventricular morphologic and histologic changes.Background. The implantable left ventricular assist device has been effective as a “bridge” to cardiac transplantation. Although there are reports documenting its circulatory support, little is known about the effects of chronic left ventricular unloading on the heart itself.Methods. We performed intraoperative transesophageal echocardiography at the insertion and explantation of a HeartMate left ventricular assist device in 19 patients with end-stage heart failure. They were supported by the assist device for 3 to 153 days (mean [±SD] 68±33). Measurements were taken retrospectively to obtain left atrial and ventricular diameters and interventricular septal and posterior wall thicknesses. Histologic examinations were made from the left ventricular myocardial specimens of 15 patients at the times of insertion and explantation for heart transplantation. Insertion and explantation specimens were compared qualitatively (0 to 3 scale) for wavy fibers, contraction band necrosis and fibrosis, with quantitative measurement of minimal myocyte diameter across the nucleus.Results. Left atrial and left ventricular diastolic and systolic diameters decreased immediately after insertion of the left ventricular assist device (from 46 to 35, 63 to 41 and 59 to 36 mm, respectively, all p < 0.001). Left ventricular wall thickness increased from 10 to 14 mm (p < 0.001) for the interventricular septum and from 10 to 13 mm for the posterior wall (p < 0.001). No echocardiographic measurements showed significant subsequent changes at the chronic stage. Myocardial histologic findings demonstrated a reduction in myocyte damage (from 1.9 to 0.5, p < 0.001, for wavy fiber and from 1.3 to 0.2, p < 0.01, for contraction band necrosis) and an increase in fibrosis (from 1.3 to 1.9, p < 0.05), but without significant change in myocyte diameter (from 15.6 to 16.8 μm, p = 0.065).Conclusions.Left ventricular unloading with the implantable assist device induces an immediate increase in wall thickness, consistent with the reduction in chamber size, thereby decreasing wall stress. Chronic unloading allows myocardial healing and fibrosis without evidence for ongoing myocyte damage or atrophy. Left ventricular assist device insertion may have a role in “resting” the ventricle for selected patients with heart failure

    The Sloan Bright Arcs Survey : Six Strongly Lensed Galaxies at z=0.4-1.4

    Get PDF
    We present new results of our program to systematically search for strongly lensed galaxies in the Sloan Digital Sky Survey (SDSS) imaging data. In this study six strong lens systems are presented which we have confirmed with follow-up spectroscopy and imaging using the 3.5m telescope at the Apache Point Observatory. Preliminary mass models indicate that the lenses are group-scale systems with velocity dispersions ranging from 466-878 km s^{-1} at z=0.17-0.45 which are strongly lensing source galaxies at z=0.4-1.4. Galaxy groups are a relatively new mass scale just beginning to be probed with strong lensing. Our sample of lenses roughly doubles the confirmed number of group-scale lenses in the SDSS and complements ongoing strong lens searches in other imaging surveys such as the CFHTLS (Cabanac et al 2007). As our arcs were discovered in the SDSS imaging data they are all bright (r22r\lesssim22), making them ideally suited for detailed follow-up studies.Comment: 13 pages, 3 figures, submitted to ApJL, the Sloan Bright Arcs page is located here: http://home.fnal.gov/~kubo/brightarcs.htm

    Mechanical Characterisation of Pneumatically-Spliced Carbon Fibre Yarns as Reinforcements for Polymer Composites

    Get PDF
    An investigation into the mechanical response of pneumatically-spliced carbon fibre yarns as a potential reinforcing material for polymer composites is presented. High strength mechanical connections between carbon fibre yarns are produced by joining short discontinuous tows into longer lengths via fibre entanglement. The effect of altering the number of high-pressure air pulses fired by a commercially available (Airbond 701H) splicing machine, to form the tow-tow connection, on load bearing capacity and linear stiffness is first evaluated on splices between virgin T700SC-24K-50C carbon fibre tows. The best performing spliced configuration is subsequently utilised in reinforcing unidirectional epoxy laminates, which are mechanically characterised, and their properties compared to those of various continuous fibre and chopped strand mat panels. Results presented in this study demonstrate that pneumatic splicing provides a high strength and sustainable solution for reinforcing polymers with discontinuous (approx. >50 mm in length) virgin, off-cut or waste carbon fibre yarns. It is speculated that with further research, quasi-continuous yarns remanufactured by splicing waste fibres could provide a novel material for weaving, braiding, non-crimp fabrics, or use in 3D printing applications
    corecore