13 research outputs found

    Neutrinos from failed supernovae at future water and liquid argon detectors

    Full text link
    We discuss the diffuse flux of electron neutrinos and antineutrinos from cosmological failed supernovae, stars that collapse directly into a black hole, with no explosion. This flux has a hotter energy spectrum compared to regular, neutron-star forming collapses, and therefore it dominates the total diffuse flux from core collapses above 20-45 MeV of neutrino energy. Reflecting the features of the originally emitted neutrinos, the flux of nu_e and anti-nu_e at Earth is larger for larger survival probability of these species, and for stiffer equations of state of nuclear matter. In the energy window 19-29 MeV, the flux from failed supernovae is susbtantial, ranging from 7% to a dominant fraction of the total flux from all core collapses. It can be as large as phi = 0.38 s^{-1} cm^{-2} for anti-nu_e (phi = 0.28 s^{-1} cm^{-2} for nue), normalized to a local rate of core collapses of R_{cc}(0)=10^{-4} yr^{-1} Mpc^{-3}. In 5 years, a 0.45 Mt water Cherenkov detector should see 5-65 events from failed supernovae, while up to 160 events are expected for the same mass with Gadolinium addition. A 0.1 Mt liquid argon experiment should record 1-11 events. Signatures of neutrinos from failed supernovae are the enhancement of the total rates of events from core collapses (up to a factor of 2) and the appearance of high energy tails in the event spectra.Comment: LaTeX, 30 pages, 10 figures, 4 tables. Some clarifications added, new section of discussion added, references updated. Version to appear in Phys. Rev.

    The effectiveness of psychosocial interventions for anxiety in children and adolescents with autism spectrum disorder:a systematic review and meta-analysis

    Get PDF
    Anxiety is a common problem in children and adolescents with autism spectrum disorder (ASD). This meta-analysis aimed to systematically evaluate the evidence for the use of psychosocial interventions to manage anxiety in this population. Cognitive behavioural therapy (CBT) was the primary intervention modality studied. A comprehensive systematic search and study selection process was conducted. Separate statistical analyses were carried out for clinician-, parent-, and self-reported outcome measures. Sensitivity analyses were conducted by removing any outlying studies and any studies that did not use a CBT intervention. A subgroup analysis was performed to compare individual and group delivery of treatment. Ten randomised control trials involving a total of 470 participants were included. The overall SMD was d = 1.05 (95 % CI 0.45, 1.65; z = 3.45, p = 0.0006) for clinician- reported outcome measures; d = 1.00 (95%CI 0.21, 1.80; z = 2.47, p = 0.01) for parent-reported outcome measures; and d = 0.65 (95%CI -0.10, 1.07; z = 1.63, p = 0.10) for self-reported outcome measures. Clinician- and parent-reported outcome measures showed that psychosocial interventions were superior to waitlist and treatment-as-usual control conditions at post-treatment. However, the results of self-reported outcome measures failed to reach significance. The sensitivity analyses did not significantly change these results and the subgroup analysis indicated that individual treatment was more effective than group treatment. The main limitations of this review were the small number of included studies as well as the clinical and methodological variability between studies

    Effects of eight neuropsychiatric copy number variants on human brain structure

    Get PDF
    Many copy number variants (CNVs) confer risk for the same range of neurodevelopmental symptoms and psychiatric conditions including autism and schizophrenia. Yet, to date neuroimaging studies have typically been carried out one mutation at a time, showing that CNVs have large effects on brain anatomy. Here, we aimed to characterize and quantify the distinct brain morphometry effects and latent dimensions across 8 neuropsychiatric CNVs. We analyzed T1-weighted MRI data from clinically and non-clinically ascertained CNV carriers (deletion/duplication) at the 1q21.1 (n = 39/28), 16p11.2 (n = 87/78), 22q11.2 (n = 75/30), and 15q11.2 (n = 72/76) loci as well as 1296 non-carriers (controls). Case-control contrasts of all examined genomic loci demonstrated effects on brain anatomy, with deletions and duplications showing mirror effects at the global and regional levels. Although CNVs mainly showed distinct brain patterns, principal component analysis (PCA) loaded subsets of CNVs on two latent brain dimensions, which explained 32 and 29% of the variance of the 8 Cohen’s d maps. The cingulate gyrus, insula, supplementary motor cortex, and cerebellum were identified by PCA and multi-view pattern learning as top regions contributing to latent dimension shared across subsets of CNVs. The large proportion of distinct CNV effects on brain morphology may explain the small neuroimaging effect sizes reported in polygenic psychiatric conditions. Nevertheless, latent gene brain morphology dimensions will help subgroup the rapidly expanding landscape of neuropsychiatric variants and dissect the heterogeneity of idiopathic conditions

    Outcomes of Robot-assisted Partial Nephrectomy for Clinical T2 Renal Tumors: A Multicenter Analysis (ROSULA Collaborative Group).

    Get PDF
    BACKGROUND: While partial nephrectomy (PN) represents the standard surgical management for cT1 renal masses, its role for cT2 tumors is controversial. Robot-assisted PN (RAPN) is being increasingly implemented worldwide. OBJECTIVE: To analyze perioperative, functional, and oncological outcomes of RAPN for cT2 tumors. DESIGN, SETTING, AND PARTICIPANTS: Retrospective analysis of a large multicenter, multinational dataset of patients with nonmetastatic cT2 masses treated with robotic surgery (ROSULA: RObotic SUrgery for LArge renal mass). INTERVENTION: Robotic-assisted PN. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Patients\u27 demographics, lesion characteristics, perioperative variables, renal functional data, pathology, and oncological data were analyzed. Univariable and multivariable regression analyses assessed the relationships with the risk of intra-/postoperative complications, recurrence, and survival. RESULTS AND LIMITATIONS: A total of 298 patients were analyzed. Median tumor size was 7.6 (7-8.5) cm. Median RENAL score was 9 (8-10). Median ischemia time was 25 (20-32) min. Median estimated blood loss was 150 (100-300) ml. Sixteen patients had intraoperative complications (5.4%), whereas 66 (22%) had postoperative complications (5% were Clavien grade ≥3). Multivariable analysis revealed that a lower RENAL score (odds ratio [OR] 0.46, 95% confidence interval [CI] 0.21-0.65, p=0.02) and pathological pT2 stage (OR 0.51, 95% CI 0.12-0.86, p=0.001) were protective against postoperative complications. A total of 243 lesions (82%) were malignant. Twenty patients (8%) had positive surgical margins. Ten deaths and 25 recurrences/metastases occurred at a median follow-up of 12 (5-35) mo. At univariable analysis, higher pT stage was predictive of a likelihood of recurrences/metastases (p=0.048). While there was a significant deterioration of renal function at discharge, this remained stable over time at 1-yr follow-up. The main limitation of this study is its retrospective design. CONCLUSIONS: RAPN in the setting of select cT2 renal masses can safely be performed with acceptable outcomes. Further studies are warranted to corroborate our findings and to better define the role of robotic nephron sparing for this challenging indication. PATIENT SUMMARY: This report shows that robotic surgery can be used for safe removal of a large renal tumor in a minimally invasive fashion, maximizing preservation of renal function, and without compromising cancer control

    Outcomes of Robot-assisted Partial Nephrectomy for Clinical T2 Renal Tumors: A Multicenter Analysis (ROSULA Collaborative Group).

    No full text
    BACKGROUND: While partial nephrectomy (PN) represents the standard surgical management for cT1 renal masses, its role for cT2 tumors is controversial. Robot-assisted PN (RAPN) is being increasingly implemented worldwide. OBJECTIVE: To analyze perioperative, functional, and oncological outcomes of RAPN for cT2 tumors. DESIGN, SETTING, AND PARTICIPANTS: Retrospective analysis of a large multicenter, multinational dataset of patients with nonmetastatic cT2 masses treated with robotic surgery (ROSULA: RObotic SUrgery for LArge renal mass). INTERVENTION: Robotic-assisted PN. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Patients\u27 demographics, lesion characteristics, perioperative variables, renal functional data, pathology, and oncological data were analyzed. Univariable and multivariable regression analyses assessed the relationships with the risk of intra-/postoperative complications, recurrence, and survival. RESULTS AND LIMITATIONS: A total of 298 patients were analyzed. Median tumor size was 7.6 (7-8.5) cm. Median RENAL score was 9 (8-10). Median ischemia time was 25 (20-32) min. Median estimated blood loss was 150 (100-300) ml. Sixteen patients had intraoperative complications (5.4%), whereas 66 (22%) had postoperative complications (5% were Clavien grade ≥3). Multivariable analysis revealed that a lower RENAL score (odds ratio [OR] 0.46, 95% confidence interval [CI] 0.21-0.65, p=0.02) and pathological pT2 stage (OR 0.51, 95% CI 0.12-0.86, p=0.001) were protective against postoperative complications. A total of 243 lesions (82%) were malignant. Twenty patients (8%) had positive surgical margins. Ten deaths and 25 recurrences/metastases occurred at a median follow-up of 12 (5-35) mo. At univariable analysis, higher pT stage was predictive of a likelihood of recurrences/metastases (p=0.048). While there was a significant deterioration of renal function at discharge, this remained stable over time at 1-yr follow-up. The main limitation of this study is its retrospective design. CONCLUSIONS: RAPN in the setting of select cT2 renal masses can safely be performed with acceptable outcomes. Further studies are warranted to corroborate our findings and to better define the role of robotic nephron sparing for this challenging indication. PATIENT SUMMARY: This report shows that robotic surgery can be used for safe removal of a large renal tumor in a minimally invasive fashion, maximizing preservation of renal function, and without compromising cancer control
    corecore