26 research outputs found

    Improved survival of left ventricular assist device carriers in Europe according to implantation eras: results from the PCHF-VAD registry

    Full text link
    AIMS Temporal changes in patient selection and major technological developments have occurred in the field of left ventricular assist devices (LVADs), yet analyses depicting this trend are lacking for Europe. We describe the advances of European LVAD programmes from the PCHF-VAD registry across device implantation eras. METHODS AND RESULTS Of 583 patients from 13 European centres in the registry, 556 patients (mean age 53 ± 12 years, 82% male) were eligible for this analysis. Patients were divided into eras (E) by date of LVAD implantation: E1 from December 2006 to December 2012 (6 years), E2 from January 2013 to January 2020 (7 years). Patients implanted more recently were older with more comorbidities, but less acutely ill. Receiving an LVAD in E2 was associated with improved 1-year survival in adjusted analysis (hazard ratio [HR] 0.58, 95% confidence interval [CI] 0.35-0.98; p = 0.043). LVAD implantation in E2 was associated with a significantly lower chance of heart transplantation (adjusted HR 0.40, 95% CI 0.23-0.67; p = 0.001), and lower risk of LVAD-related infections (adjusted HR 0.64, 95% CI 0.43-0.95; p = 0.027), both in unadjusted and adjusted analyses. The adjusted risk of haemocompatibility-related events decreased (HR 0.60, 95% CI 0.39-0.91; p = 0.016), while heart failure-related events increased in E2 (HR 1.67, 95% CI 1.02-2.75; p = 0.043). CONCLUSION In an analysis depicting the evolving landscape of continuous-flow LVAD carriers in Europe over 13 years, a trend towards better survival was seen in recent years, despite older recipients with more comorbidities, potentially attributable to increasing expertise of LVAD centres, improved patient selection and pump technology. However, a smaller chance of undergoing heart transplantation was noted in the second era, underscoring the relevance of improved outcomes on LVAD support

    Impact of progressive aortic regurgitation on outcomes after left ventricular assist device implantation

    Full text link
    Aortic regurgitation (AR) following continuous flow left ventricular assist device implantation (cf-LVAD) may adversely impact outcomes. We aimed to assess the incidence and impact of progressive AR after cf-LVAD on prognosis, biomarkers, functional capacity and echocardiographic findings. In an analysis of the PCHF-VAD database encompassing 12 European heart failure centers, patients were dichotomized according to the progression of AR following LVAD implantation. Patients with de-novo AR or AR progression (AR_1) were compared to patients without worsening AR (AR_0). Among 396 patients (mean age 53 ± 12 years, 82% male), 153 (39%) experienced progression of AR over a median of 1.4 years on LVAD support. Before LVAD implantation, AR_1 patients were less frequently diabetic, had lower body mass indices and higher baseline NT-proBNP values. Progressive AR did not adversely impact mortality (26% in both groups, HR 0.91 [95% CI 0.61-1.36]; P = 0.65). No intergroup variability was observed in NT-proBNP values and 6-minute walk test results at index hospitalization discharge and at 6-month follow-up. However, AR_1 patients were more likely to remain in NYHA class III and had worse right ventricular function at 6-month follow-up. Lack of aortic valve opening was related to de-novo or worsening AR (P < 0.001), irrespective of systolic blood pressure (P = 0.67). Patients commonly experience de-novo or worsening AR when exposed to continuous flow of contemporary LVADs. While reducing effective forward flow, worsening AR did not influence survival. However, less complete functional recovery and worse RV performance among AR_1 patients were observed. Lack of aortic valve opening was associated with progressive AR

    Impact of 14-day bed rest on serum adipokines and low-grade inflammation in younger and older adults

    No full text
    Ageing and inactivity both contribute to systemic inflammation, but the effects of inactivity on inflammation in healthy elderly individuals have not been elucidated. We hypothesised that 14-day bed rest could affect the pro- and anti-inflammatory markers in young subjects differently than in older adults. A short-term 14-day horizontal bed rest study (BR14) has been used as a model of inactivity in two groups of healthy male volunteers: 7 aged 18–30 years (young) and 16 aged 55–65 years (older adults). The effects of inactivity on inflammation were compared. Key low-grade inflammation mediators, tumour necrosis factor α (TNF-α), interleukin-6 (IL-6), visfatin, resistin, and anti-inflammatory adiponectin were measured in fasting serum samples, collected at baseline (BDC) and post BR14. Young responded to BR14 by increasing serum visfatin and resistin while older adults responded to BR14 by increasing IL-6 and TNF-α. In addition, serum adiponectin increased in all participants. Data from correlation analysis demonstrated positive association between Δ serum visfatin and Δ IL-6 in both groups, while Δ serum adiponectin was negatively associated with Δ TNF-α in young and positively associated with Δ resistin in the older adults. As little as 14 days of complete physical inactivity (BR14) negatively affected markers of low-grade inflammation in both groups, but the inflammation after BR14 was more pronounced in older adults. The effect of BR14 on IL-6 and resistin differed between young and older adults. Inflammatory responses to BR14 in older adults differed from those reported in the literature for obese or subjects in pathological states, suggesting potentially different mechanisms between inactivity- and obesity-induced inflammations

    Structural changes in the rat placenta during the last third of gestation discovered by stereology

    Get PDF
    Structural changes in the rat placenta during the last third of gestation were for the first time assessed by stereology. Fischer female rats were euthanized on the day 16 or day 19 of gestation, and 35 placentas were collected. Three randomly selected placentas from each group were stereologically analyzed for the absolute volume. The proportion of the glycogenic cells and the trophoblast giant cells (TGC) in the basal part of the placenta was calculated using volume density.  The absolute volume of the rat placenta on the day 16 of gestation was determined as 0.0638 cm3. The labyrinth comprised 0.0274 cm3, the basal plate 0.0271 cm3 and the decidua 0.0093 cm3. On the day 19 of gestation, the absolute volume of the placenta was 0.1627 cm3, the labyrinth occupied 0.0922 cm3, the basal plate 0.0596 cm3 and the decidua 0.0109 cm3. The volume density of trophoblast giant cells was 0.174 cm0 on the day 16 and 0.107 cm0 on the day 19 of gestation. The glycogenic cells comprised 0.379 percentage of the basal plate on the day 16 and 0.236 on the day 19 of gestation. We conclude that the absolute volume of the whole placenta and the labyrinth has increased from day 16 to the day 19 of gestation. In contrast, the volume density of glycogenic cells and trophoblast giant cells was higher on the day 16 than on the day 19 of gestation, probably due to the intensive trophoblast invasion during that time

    Cardiovascular implantable electronic device therapy in patients with left ventricular assist devices

    Get PDF
    Background: There is conflicting observational data on the survival benefit cardiac implantable electronic devices (CIED) in patients with LVADs. Methods: Patients in whom an LVAD was implanted between January 2008 and April 2017 in the multinational Trans-Atlantic Registry on VAD and Transplant (TRAViATA) registry were separated into four groups based on the presence of CIED prior to LVAD implantation: none (n = 146), implantable cardiac defibrillator (ICD) (n = 239), cardiac resynchronization without defibrillator (CRT-P) (n = 28), and CRT with defibrillator (CRT-D) (n = 111). Results: A total of 524 patients (age 52 years ±12, 84.4% male) were followed for 354 (interquartile range: 166–701) days. After multivariable adjustment, there were no differences in survival across the groups. In comparison to no device, only CRT-D was associated with late right ventricular failure (RVF) (hazard ratio 2.85, 95% confidence interval [CI] 1.42–5.72, p = 0.003). There was no difference in risk of early RVF across the groups or risk of ICD shocks between those with ICD and CRT-D. Conclusion: In a multinational registry of patients with LVADs, there were no differences in survival with respect to CIED subtype. However, patients with a pre-existing CRT-D had a higher likelihood of late RVF suggesting significant lo

    Impact of progressive aortic regurgitation on outcomes after left ventricular assist device implantation.

    No full text
    Aortic regurgitation (AR) following continuous flow left ventricular assist device implantation (cf-LVAD) may adversely impact outcomes. We aimed to assess the incidence and impact of progressive AR after cf-LVAD on prognosis, biomarkers, functional capacity and echocardiographic findings. In an analysis of the PCHF-VAD database encompassing 12 European heart failure centers, patients were dichotomized according to the progression of AR following LVAD implantation. Patients with de-novo AR or AR progression (AR_1) were compared to patients without worsening AR (AR_0). Among 396 patients (mean age 53 ± 12 years, 82% male), 153 (39%) experienced progression of AR over a median of 1.4 years on LVAD support. Before LVAD implantation, AR_1 patients were less frequently diabetic, had lower body mass indices and higher baseline NT-proBNP values. Progressive AR did not adversely impact mortality (26% in both groups, HR 0.91 [95% CI 0.61-1.36]; P = 0.65). No intergroup variability was observed in NT-proBNP values and 6-minute walk test results at index hospitalization discharge and at 6-month follow-up. However, AR_1 patients were more likely to remain in NYHA class III and had worse right ventricular function at 6-month follow-up. Lack of aortic valve opening was related to de-novo or worsening AR (P < 0.001), irrespective of systolic blood pressure (P = 0.67). Patients commonly experience de-novo or worsening AR when exposed to continuous flow of contemporary LVADs. While reducing effective forward flow, worsening AR did not influence survival. However, less complete functional recovery and worse RV performance among AR_1 patients were observed. Lack of aortic valve opening was associated with progressive AR
    corecore