    Audio-visual speech processing system for Polish applicable to human-computer interaction

    Get PDF
    This paper describes audio-visual speech recognition system for Polish language and a set of performance tests under various acoustic conditions. We first present the overall structure of AVASR systems with three main areas: audio features extraction, visual features extraction and subsequently, audiovisual speech integration. We present MFCC features for audio stream with standard HMM modeling technique, then we describe appearance and shape based visual features. Subsequently we present two feature integration techniques, feature concatenation and model fusion. We also discuss the results of a set of experiments conducted to select best system setup for Polish, under noisy audio conditions. Experiments are simulating human-computer interaction in computer control case with voice commands in difficult audio environments. With Active Appearance Model (AAM) and multistream Hidden Markov Model (HMM) we can improve system accuracy by reducing Word Error Rate for more than 30%, comparing to audio-only speech recognition, when Signal-to-Noise Ratio goes down to 0dB

    Komórki macierzyste serca

    Get PDF

    Two-dimensional versus three-dimensional transesophageal echocardiography in percutaneous left atrial appendage occlusion

    Get PDF
    Background: Real-time three-dimensional transesophageal echocardiography (RT3D TEE) enablesbetter visualization of the left atrial appendage (LAA) and may be superior to real-time two-dimensionaltransesophageal echocardiography (RT2D TEE) for LAA occlusion (LAAO). The aim of this study wasto assess inter- and intra-observer variability of RT2D TEE and RT3D TEE measurements of LAA,and to assess the accordance of RT2D TEE and RT3D TEE with appropriate occluder selection.Methods: Transesophageal echocardiography was performed in 40 patients during LAAO. RT2DTEE and RT3D TEE measurements of the ostium and landing zone were performed independently bytwo echocardiographers. The appropriate choice of occluder was confirmed with fluoroscopic criteria.After the procedures, RT2D TEE and RT3D TEE evaluation were repeated separately by the sameechocardiographers.Results: The mean ostium diameters by RT2D TEE obtained by the two observers were 23.6 ± 4.2 vs.24.8 ± 5.2 (p = 0.04), and the mean landing zone diameters were 17.7 ± 4.4 vs. 19.4 ± 3.9 (p < 0.01).In the case of RT3D TEE, the ostium diameters were 29.6 ± 5.3 vs. 29.4 ± 6.4 (p = not significant[NS]) and the landing zone diameters were 21.4 ± 3.8 vs. 21.6 ± 3.9 (p = NS). Intra-observer differenceswere absent in the case of RT3D TEE. The comparison of RT2D TEE vs. RT3D TEE analysesperformed by the same echocardiographer revealed significant differences in the ostium and landingzone measurements (both p < 0.01). Agreement between the suggested device size was better for RT3DTEE (weighted kappa was 0.62 vs. 0.28, respectively).Conclusions: The results obtained with RT3D TEE showed significantly larger dimensions of theostium and the landing zone. RT3D TEE showed lesser inter- and intra-observer variability and betteragreement with the implanted device

    Dyssynchronous Left Ventricular Activation is Insufficient for the Breakdown of Wringing Rotation

    Get PDF
    Cardiac resynchronization therapy is a valuable tool to restore left ventricular function in patients experiencing dyssynchronous ventricular activation. However, the non-responder rate is still as high as 40%. Recent studies suggest that left ventricular torsion or specifically the lack thereof might be a good predictor for the response of cardiac resynchronization therapy. Since left ventricular torsion is governed by the muscle fiber orientation and the heterogeneous electromechanical activation of the myocardium, understanding the relation between these components and the ability to measure them is vital. To analyze if locally altered electromechanical activation in heart failure patients affects left ventricular torsion, we conducted a simulation study on 27 personalized left ventricular models. Electroanatomical maps and late gadolinium enhanced magnetic resonance imaging data informed our in-silico model cohort. The angle of rotation was evaluated in every material point of the model and averaged values were used to classify the rotation as clockwise or counterclockwise in each segment and sector of the left ventricle. 88% of the patient models (n = 24) were classified as a wringing rotation and 12% (n = 3) as a rigid-body-type rotation. Comparison to classification based on in vivo rotational NOGA XP maps showed no correlation. Thus, isolated changes of the electromechanical activation sequence in the left ventricle are not sufficient to reproduce the rotation pattern changes observed in vivo and suggest that further patho-mechanisms are involved

    Mobilization of CD34+CXCR4+ Stem/Progenitor Cells and the Parameters of Left Ventricular Function and Remodeling in 1-Year Follow-up of Patients with Acute Myocardial Infarction

    Get PDF
    Mobilization of stem cells in acute MI might signify the reparatory response. Aim of the Study. Prospective evaluation of correlation between CD34+CXCR4+ cell mobilization and improvement of LVEF and remodeling in patients with acute MI in 1-year followup. Methods. 50 patients with MI, 28 with stable angina (SAP), and 20 individuals with no CAD (CTRL). CD34+CXCR4+ cells, SDF-1, G-CSF, troponin I (TnI) and NT-proBNP were measured on admission and 1 year after MI. Echocardiography and ergospirometry were carried out after 1 year. Results. Number of CD34+CXCR4+ cells in acute MI was significantly higher in comparison with SAP and CTRL, but lower in patients with decreased LVEF ≤40%. In patients who had significant LVEF increase ≥5% in 1 year FU the number of cells in acute MI was significantly higher versus patients with no LVEF improvement. Number of cells was positively correlated (r = 0,41, P = 0,031) with absolute LVEF change and inversely with absolute change of ESD and EDD in 1-year FU. Mobilization of CD34+CXCR4+ cells in acute MI was negatively correlated with maximum TnI and NT-proBNP levels. Conclusion. Mobilization of CD34+CXCR4+ cells in acute MI shows significant positive correlation with improvement of LVEF after 1 year

    Effects of trans-endocardial delivery of bone marrow-derived CD133+ cells on angina and quality of life in patients with refractory angina: A sub-analysis of the REGENT-VSEL trial

    Get PDF
    Background: The REGENT-VSEL trial demonstrated a neutral effect of transendocardial injection of autologous bone marrow (BM)-derived CD133+ in regard to myocardial ischemia. The current sub-analysis of the REGENT VSEL trial aims to assess the effect stem cell therapy has on quality of life (QoL) in patients with refractory angina.Methods: Thirty-one patients (63.0 ± 6.4 years, 70% male) with recurrent CCS II–IV angina, despite optimal medical therapy, enrolled in the REGENT-VSEL single center, randomized, double-blinded, and placebo-controlled trial. Of the 31 patients, 16 individuals were randomly assigned to the active stem cell group and 15 individuals were randomly assigned to the placebo group on a 1:1 basis. The inducibility of ischemia, (≥ one myocardial segment) was confirmed for each patient using Tc-99m SPECT. QoL was measured using the Seattle Angina Questionnaire. Each patient completed the questionnaire prior to treatment and at the time of their outpatient follow-up visits at 1, 4, 6, and 12 months after cell/placebo treatment.Results: The main finding of the REGENT-VSEL trial sub-analysis was that transendocardial injection of autologous BM-derived CD133+ stem cells in patients with chronic refractory angina did not show significant improvement in QoL in comparison to the control group. Moreover, there was no significant difference between cell therapy and placebo in a number of patients showing improvement of at least 1 Canadian Cardiovascular Society class during the follow-up period.Conclusions: Intra-myocardial delivery of autologous CD133+ stem cells is safe and feasible but does not show a significant improvement in the QoL or angina pectoris symptoms in patients with chronic myocardial ischemia

    STereotactic Arrhythmia Radioablation (STAR): the Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary consortium (STOPSTORM.eu) and review of current patterns of STAR practice in Europe

    Full text link
    The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions' experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs
    corecore