522 research outputs found
Radiological Decision Aid to determine suitability for medial unicompartmental knee arthroplasty: development and preliminary validation
Aims: An evidence-based radiographic Decision Aid for meniscal-bearing unicompartmental knee arthroplasty (UKA) has been developed and this study investigates its performance at an independent centre. Patients: and Methods Pre-operative radiographs, including stress views, from a consecutive cohort of 550 knees undergoing arthroplasty (UKA or total knee arthroplasty; TKA) by a single-surgeon were assessed. Suitability for UKA was determined using the Decision Aid, with the assessor blinded to treatment received, and compared with actual treatment received, which was determined by an experienced UKA surgeon based on history, examination, radiographic assessment including stress radiographs, and intra-operative assessment in line with the recommended indications as described in the literature. Results: The sensitivity and specificity of the Decision Aid was 92% and 88%, respectively. Excluding knees where a clear pre-operative plan was made to perform TKA, i.e. patient request, the sensitivity was 93% and specificity 96%. The false-positive rate was low (2.4%) with all affected patients readily identifiable during joint inspection at surgery. In patients meeting Decision Aid criteria and receiving UKA, the five-year survival was 99% (95% confidence intervals (CI) 97 to 100). The false negatives (3.5%), who received UKA but did not meet the criteria, had significantly worse functional outcomes (flexion p < 0.001, American Knee Society Score - Functional p < 0.001, University of California Los Angeles score p = 0.04), and lower implant survival of 93.1% (95% CI 77.6 to 100). Conclusion: The radiographic Decision Aid safely and reliably identifies appropriate patients for meniscal-bearing UKA and achieves good results in this population. The widespread use of the Decision Aid should improve the results of UKA
What are we measuring? A critique of range of motion methods currently in use for Dupuytren's disease and recommendations for practice
Background: Range of motion is the most frequently reported measure used in practice to evaluate outcomes.
A goniometer is the most reliable tool to assess range of motion yet, the lack of consistency in reporting prevents comparison between studies. The aim of this study is to identify how range of motion is currently assessed and reported in Dupuytren’s disease literature. Following analysis recommendations for practice will be made to enable consistency in future studies for comparability. This paper highlights the variation in range of motion reporting in Dupuytren’s disease.
Methods: A Participants, Intervention, Comparison, Outcomes and Study design format was used for the search strategy and search terms. Surgery, needle fasciotomy or collagenase injection for primary or recurrent Dupuytren’s disease in adults were included if outcomes were monitored using range of motion to record change. A literature search was performed in May 2013 using subject heading and free-text terms to also capture electronic publications ahead of print. In total 638 publications were identified and following screening 90 articles met the inclusion criteria. Data was extracted and entered onto a spreadsheet for analysis. A thematic analysis was carried out to establish any duplication, resulting in the final range of motion measures identified.
Results: Range of motion measurement lacked clarity, with goniometry reportedly used in only 43 of the 90 studies, 16 stated the use of a range of motion protocol. A total of 24 different descriptors were identified describing range of motion in the 90 studies. While some studies reported active range of motion, others reported passive or were unclear. Eight of the 24 categories were identified through thematic analysis as possibly describing the same measure, ‘lack of joint extension’ and accounted for the most frequently used. Conclusions: Published studies lacked clarity in reporting range of motion, preventing data comparison and
meta-analysis. Percentage change lacks context and without access to raw data, does not allow direct comparison of baseline characteristics. A clear description of what is being measured within each study was required. It is recommended that range of motion measuring and reporting for Dupuytren’s disease requires consistency to address issues that fall into 3 main categories:-
Definition of terms
Protocol statement
Outcome reportin
Examining intra-rater and inter-rater response agreement: A medical chart abstraction study of a community-based asthma care program
<p>Abstract</p> <p>Background</p> <p>To assess the intra- and inter-rater agreement of chart abstractors from multiple sites involved in the evaluation of an Asthma Care Program (ACP).</p> <p>Methods</p> <p>For intra-rater agreement, 110 charts randomly selected from 1,433 patients enrolled in the ACP across eight Ontario communities were re-abstracted by 10 abstractors. For inter-rater agreement, data abstractors reviewed a set of eight fictitious charts. Data abstraction involved information pertaining to six categories: physical assessment, asthma control, spirometry, asthma education, referral visits, and medication side effects. Percentage agreement and the kappa statistic (κ) were used to measure agreement. Sensitivity and specificity estimates were calculated comparing results from all raters against the gold standard.</p> <p>Results</p> <p>Intra-rater re-abstraction yielded an overall kappa of 0.81. Kappa values for the chart abstraction categories were: physical assessment (κ 0.84), asthma control (κ 0.83), spirometry (κ 0.84), asthma education (κ 0.72), referral visits (κ 0.59) and medication side effects (κ 0.51). Inter-rater abstraction of the fictitious charts produced an overall kappa of 0.75, sensitivity of 0.91 and specificity of 0.89. Abstractors demonstrated agreement for physical assessment (κ 0.88, sensitivity and specificity 0.95), asthma control (κ 0.68, sensitivity 0.89, specificity 0.85), referral visits (κ 0.77, sensitivity 0.88, specificity 0.95), and asthma education (κ 0.49, sensitivity 0.87, specificity 0.77).</p> <p>Conclusion</p> <p>Though collected by multiple abstractors, the results show high sensitivity and specificity and substantial to excellent inter- and intra-rater agreement, assuring confidence in the use of chart abstraction for evaluating the ACP.</p
Identifying a Window of Vulnerability during Fetal Development in a Maternal Iron Restriction Model
It is well acknowledged from observations in humans that iron deficiency during pregnancy can be associated with a number of developmental problems in the newborn and developing child. Due to the obvious limitations of human studies, the stage during gestation at which maternal iron deficiency causes an apparent impairment in the offspring remains elusive. In order to begin to understand the time window(s) during pregnancy that is/are especially susceptible to suboptimal iron levels, which may result in negative effects on the development of the fetus, we developed a rat model in which we were able to manipulate and monitor the dietary iron intake during specific stages of pregnancy and analyzed the developing fetuses. We established four different dietary-feeding protocols that were designed to render the fetuses iron deficient at different gestational stages. Based on a functional analysis that employed Auditory Brainstem Response measurements, we found that maternal iron restriction initiated prior to conception and during the first trimester were associated with profound changes in the developing fetus compared to iron restriction initiated later in pregnancy. We also showed that the presence of iron deficiency anemia, low body weight, and changes in core body temperature were not defining factors in the establishment of neural impairment in the rodent offspring
Item response theory analysis of the recoded Internet Gaming Disorder Scale-Short-Form (IGDS9-SF)
Based on the nine criteria for Internet gaming disorder (IGD) in DSM-5, the Internet Gaming Disorder Scale 9-Short Form (IGDS9-SF; Pontes and Griffiths 2015) is the most widely used questionnaire for assessing IGD. The present study examined support for the unidimensional factor structure of the instrument, with a group of 868 adolescent and adult gamers from the USA, with criteria recoded as present or absent. The two-parameter logistic model (2PLM) was used to examine the item response theory properties of the criteria included in the measure. Confirmatory factor analysis supported the one-factor model. The 2PLM analysis indicated that all the criteria were strong discriminators of high and low latent IGD. Furthermore, the items measured more of the GAD dimension and with more precision from around +2 SD from the mean trait level. The implications of the findings for interpreting the IGDS9-SF scores for clinical practice are discussed
Optimal functional outcome measures for assessing treatment for Dupuytren's disease: A systematic review and recommendations for future practice
This article is available through the Brunel Open Access Publishing Fund. Copyright © 2013 Ball et al.; licensee BioMed Central Ltd.Background: Dupuytren's disease of the hand is a common condition affecting the palmar fascia, resulting in progressive flexion deformities of the digits and hence limitation of hand function. The optimal treatment remains unclear as outcomes studies have used a variety of measures for assessment. Methods: A literature search was performed for all publications describing surgical treatment, percutaneous needle aponeurotomy or collagenase injection for primary or recurrent Dupuytren’s disease where outcomes had been monitored using functional measures. Results: Ninety-one studies met the inclusion criteria. Twenty-two studies reported outcomes using patient reported outcome measures (PROMs) ranging from validated questionnaires to self-reported measures for return to work and self-rated disability. The Disability of Arm, Shoulder and Hand (DASH) score was the most utilised patient-reported function measure (n=11). Patient satisfaction was reported by eighteen studies but no single method was used consistently. Range of movement was the most frequent physical measure and was reported in all 91 studies. However, the methods of measurement and reporting varied, with seventeen different techniques being used. Other physical measures included grip and pinch strength and sensibility, again with variations in measurement protocols. The mean follow-up time ranged from 2 weeks to 17 years. Conclusions: There is little consistency in the reporting of outcomes for interventions in patients with Dupuytren’s disease, making it impossible to compare the efficacy of different treatment modalities. Although there are limitations to the existing generic patient reported outcomes measures, a combination of these together with a disease-specific questionnaire, and physical measures of active and passive individual joint Range of movement (ROM), grip and sensibility using standardised protocols should be used for future outcomes studies. As Dupuytren’s disease tends to recur following treatment as well as extend to involve other areas of the hand, follow-up times should be standardised and designed to capture both short and long term outcomes
Observation of an Exotic Baryon in Exclusive Photoproduction from the Deuteron
In an exclusive measurement of the reaction , a
narrow peak that can be attributed to an exotic baryon with strangeness
is seen in the invariant mass spectrum. The peak is at
GeV/c with a measured width of 0.021 GeV/c FWHM, which is largely
determined by experimental mass resolution. The statistical significance of the
peak is . The mass and width of the observed peak are
consistent with recent reports of a narrow baryon by other experimental
groups.Comment: 5 pages, 5 figure
Measurement of Beam-Spin Asymmetries for Deep Inelastic Electroproduction
We report the first evidence for a non-zero beam-spin azimuthal asymmetry in
the electroproduction of positive pions in the deep-inelastic region. Data have
been obtained using a polarized electron beam of 4.3 GeV with the CLAS detector
at the Thomas Jefferson National Accelerator Facility (JLab). The amplitude of
the modulation increases with the momentum of the pion relative to
the virtual photon, , with an average amplitude of for range.Comment: 5 pages, RevTEX4, 3 figures, 2 table
Measurement of the Polarized Structure Function for in the Resonance Region
The polarized longitudinal-transverse structure function
has been measured in the resonance region at and 0.65
GeV. Data for the reaction were taken at Jefferson Lab
with the CEBAF Large Acceptance Spectrometer (CLAS) using longitudinally
polarized electrons at an energy of 1.515 GeV. For the first time a complete
angular distribution was measured, permitting the separation of different
non-resonant amplitudes using a partial wave analysis. Comparison with previous
beam asymmetry measurements at MAMI indicate a deviation from the predicted
dependence of using recent phenomenological
models.Comment: 5 pages, LaTex, 4 eps figures: to be published in PRC/Rapid
Communications. Version 2 has revised Q^2 analysi
- …