11,299 research outputs found

    Ultrasonic Wave Dispersion and Attenuation in Fluid Filled Porous Media

    Get PDF
    The study of ultrasonic wave propagation in granular materials can lead to a better understanding of wave interaction with such materials as uncured cement and concrete. The measured parameters can then be used to investigate the curing process in particular the time required for a given mixture to consolidate. The cohesionless granular materials having loose contact between the constituent grains form a matrix that has negligible shear modulus. Sediment, sandy ground and concrete before solidification can be considered as examples of cohesionless granular materials. The shear and rigidity moduli of these materials can differ greatly from the values obtained by effective medium theories. In particular these differences could affect the ultrasonic wave propagation in such a material. In the case of cohesionless granular material the complete description of mechanical properties requires the consideration of discrete nature of the solid frame and the contact areas between the grains. Therefore wave interaction with such a material should also include the above mentioned effects. The goal of this work is to investigate the ultrasonic wave dispersion and attenuation in cohesionless granular materials the results can be to applied to the monitoring of cement and concrete during the curing process

    The role of primary healthcare professionals in oral cancer prevention and detection

    Get PDF
    AIM: To investigate current knowledge, examination habits and preventive practices of primary healthcare professionals in Scotland, with respect to oral cancer, and to determine any relevant training needs. SETTING: Primary care. METHOD: Questionnaires were sent to a random sample of 357 general medical practitioners (GMPs) and 331 dental practitioners throughout Scotland. Additionally, focus group research and interviews were conducted amongst primary healthcare team members. RESULTS: Whilst 58% of dental respondents reported examining regularly for signs of oral cancer, GMPs examined patients' mouths usually in response to a complaint of soreness. The majority of GMPs (85%) and dentists (63%) indicated that they felt less than confident in detecting oral cancer, with over 70% of GMPs identifying lack of training as an important barrier. Many practitioners were unclear concerning the relative importance of the presence of potentially malignant lesions in the oral cavity. A high proportion of the GMPs indicated that they should have a major role to play in oral cancer detection (66%) but many felt strongly that this should be primarily the remit of the dental team. CONCLUSION: The study revealed a need for continuing education programmes for primary care practitioners in oral cancer-related activities. This should aim to improve diagnostic skills and seek to increase practitioners' participation in preventive activities

    Coronary fly-through or virtual angioscopy using dual-source MDCT data

    Get PDF
    Coronary fly-through or virtual angioscopy (VA) has been studied ever since its invention in 2000. However, application was limited because it requires an optimal computed tomography (CT) scan and time-consuming post-processing. Recent advances in post-processing software facilitate easy construction of VA, but until now image quality was insufficient in most patients. The introduction of dual-source multidetector CT (MDCT) could enable VA in all patients. Twenty patients were scanned using a dual-source MDCT (Definition, Siemens, Forchheim, Germany) using a standard coronary artery protocol. Post-processing was performed on an Aquarius Workstation (TeraRecon, San Mateo, Calif.). Length travelled per major branch was recorded in millimetres, together with the time required in minutes. VA could be performed in every patient for each of the major coronary arteries. The mean (range) length of the automated fly-through was 80 (32–107) mm for the left anterior descending (LAD), 75 (21–116) mm for the left circumflex artery (LCx), and 109 (21–190) mm for the right coronary artery (RCA). Calcifications and stenoses were visualised, as well as most side branches. The mean time required was 3 min for LAD, 2.5 min for LCx, and 2 min for the RCA. Dual-source MDCT allows for high quality visualisation of the coronary arteries in every patient because scanning with this machine is independent of the heart rate. This is clearly shown by the successful VA in all patients. Potential clinical value of VA should be determined in the near future

    Technical performance and diagnostic utility of the new Elecsys (R) neuron-specific enolase enzyme immunoassay

    Get PDF
    This international multicenter study was designed to evaluate the technical performance of the new double-monoclonal, single-step Elecsys neuron-specific enolase (NSE) enzyme immunoassay (EIA) and to assess its utility as a sensitive and specific test for the diagnosis of small-cell lung cancer (SCLC). Intra and interassay coefficients of variation, determined in five control or serum specimens in six laboratories, ranged from 0.7 to 5.3 (interlaboratory median: 1.3%) and from 1.3 to 8.5 (interlaboratory median: 3.4%), respectively. Laboratory-to-laboratory comparability was excellent with respect to recovery and interassay coefficients of variation. The test was linear between 0.0 and 320 ng/ml (highest measured concentration). There was a significant correlation between NSE concentrations measured using the Elecsys NSE and the established Cobas Core NSE EIA II in all subjects (n=723) and in patients with lung cancer (n=333). However, NSE concentrations were systematically lower (approximately 9%) with the Elecsys NSE than with the comparison test. Based on a specificity of 95% in comparison with the group suffering from benign lung diseases (n=183), the cutoff value for the discrimination between malignant and benign conditions was set at 21.6 ng/ml. NSE was raised in 73.4% of SCLC patients (n=188) and was significantly higher (p<0.01) in extensive (87.8%) as opposed to limited disease (56.7%). NSE was also elevated in 16.0% of the cases with non-small cell lung cancer (NSCLC, n=374). It is concluded that the Elecsys NSE EIA is a reliable and accurate diagnostic procedure for the measurement of NSE in serum samples. The special merits of this new assay are the wide measuring range (according to manufacturers declaration up to 370 ng/ml) and a short incubation time of 18 min

    A strategy for the characterization of minute chromosome rearrangements using multiple color fluorescence in situ hybridization with chromosome-specific DNA libraries and YAC clones

    Get PDF
    The identification of marker chromosomes in clinical and tumor cytogenetics by chromosome banding analysis can create problems. In this study, we present a strategy to define minute chromosomal rearrangements by multicolor fluorescence in situ hybridization (FISH) with whole chromosome painting probes derived from chromosome-specific DNA libraries and Alu-polymerase chain reaction (PCR) products of various region-specific yeast artificial chromosome (YAC) clones. To demonstrate the usefulness of this strategy for the characterization of chromosome rearrangements unidentifiable by banding techniques, an 8p+ marker chromosome with two extra bands present in the karyotype of a child with multiple anomalies, malformations, and severe mental retardation was investigated. A series of seven-color FISH experiments with sets of fluorochrome-labeled DNA library probes from flow-sorted chromosomes demonstrated that the additional segment on 8p+ was derived from chromosome 6. For a more detailed characterization of the marker chromosome, three-color FISH experiments with library probes specific to chromosomes 6 and 8 were performed in combination with newly established telomeric and subtelomeric YAC clones from 6q25, 6p23, and 8p23. These experiments demonstrated a trisomy 6pter6p22 and a monosomy 8pter8p23 in the patient. The present limitations for a broad application of this strategy and its possible improvements are discusse

    Visual art inspired by the collective feeding behavior of sand-bubbler crabs

    Full text link
    Sand--bubblers are crabs of the genera Dotilla and Scopimera which are known to produce remarkable patterns and structures at tropical beaches. From these pattern-making abilities, we may draw inspiration for digital visual art. A simple mathematical model is proposed and an algorithm is designed that may create such sand-bubbler patterns artificially. In addition, design parameters to modify the patterns are identified and analyzed by computational aesthetic measures. Finally, an extension of the algorithm is discussed that may enable controlling and guiding generative evolution of the art-making process

    The effect of time constraint on anticipation, decision making, and option generation in complex and dynamic environments

    Get PDF
    Researchers interested in performance in complex and dynamic situations have focused on how individuals predict their opponent(s) potential courses of action (i.e., during assessment) and generate potential options about how to respond (i.e., during intervention). When generating predictive options, previous research supports the use of cognitive mechanisms that are consistent with long-term working memory (LTWM) theory (Ericsson and Kintsch in Phychol Rev 102(2):211–245, 1995; Ward et al. in J Cogn Eng Decis Mak 7:231–254, 2013). However, when generating options about how to respond, the extant research supports the use of the take-the-first (TTF) heuristic (Johnson and Raab in Organ Behav Hum Decis Process 91:215–229, 2003). While these models provide possible explanations about how options are generated in situ, often under time pressure, few researchers have tested the claims of these models experimentally by explicitly manipulating time pressure. The current research investigates the effect of time constraint on option-generation behavior during the assessment and intervention phases of decision making by employing a modified version of an established option-generation task in soccer. The results provide additional support for the use of LTWM mechanisms during assessment across both time conditions. During the intervention phase, option-generation behavior appeared consistent with TTF, but only in the non-time-constrained condition. Counter to our expectations, the implementation of time constraint resulted in a shift toward the use of LTWM-type mechanisms during the intervention phase. Modifications to the cognitive-process level descriptions of decision making during intervention are proposed, and implications for training during both phases of decision making are discussed
    • …
    corecore