12 research outputs found

    Respiratory-gated (4D) contrast-enhanced FDG PET-CT for radiotherapy planning of lower oesophageal carcinoma: Feasibility and impact on planning target volume

    Get PDF
    Background: To assess the feasibility and potential impact on target delineation of respiratory-gated (4D) contrast-enhanced 18 Fluorine fluorodeoxyglucose (FDG) positron emission tomography - computed tomography (PET-CT), in the treatment planning position, for a prospective cohort of patients with lower third oesophageal cancer. Methods: Fifteen patients were recruited into the study. Imaging included 4D PET-CT, 3D PET-CT, endoscopic ultrasound and planning 4D CT. Target volume delineation was performed on 4D CT, 4D CT with co-registered 3D PET and 4D PET-CT. Planning target volumes (PTV) generated with 4D CT (PTV 4DCT), 4D CT co-registered with 3D PET-CT (PTV 3DPET4DCT) and 4D PET-CT (PTV 4DPETCT ) were compared with multiple positional metrics. Results: Mean PTV 4DCT , PTV 3DPET4DCT and PTV 4DPETCT were 582.4 ± 275.1 cm 3 , 472.5 ± 193.1 cm 3 and 480.6 ± 236.9 cm 3 respectively (no significant difference). Median DICE similarity coefficients comparing PTV 4DCT with PTV 3DPET4DCT, PTV 4DCT with PTV 4DPETCT and PTV 3DPET4DCT with PTV 4DPETCT were 0.85 (range 0.65-0.9), 0.85 (range 0.69-0.9) and 0.88 (range 0.79-0.9) respectively. The median sensitivity index for overlap comparing PTV 4DCT with PTV 3DPET4DCT, PTV 4DCT with PTV 4DPETCT and PTV 3DPET4DCT with PTV 4DPETCT were 0.78 (range 0.65-0.9), 0.79 (range 0.65-0.9) and 0.89 (range 0.68-0.94) respectively. Conclusions: Planning 4D PET-CT is feasible with careful patient selection. PTV generated using 4D CT, 3D PET-CT and 4D PET-CT were of similar volume, however, overlap analysis demonstrated that approximately 20% of PTV 3DPETCT and PTV 4DPETCT are not included in PTV 4DCT , leading to under-coverage of target volume and a potential geometric miss. Additionally, differences between PTV 3DPET4DCT and PTV 4DPETCT suggest a potential benefit for 4D PET-CT. Trial registration: ClinicalTrials.gov Identifier - NCT02285660(Registered 21/10/2014)

    IMRT treatment plans and functional planning with functional lung imaging from 4D-CT for thoracic cancer patients

    Get PDF
    <p>Abstract</p> <p>Background and purpose</p> <p>Currently, the inhomogeneity of the pulmonary function is not considered when treatment plans are generated in thoracic cancer radiotherapy. This study evaluates the dose of treatment plans on highly-functional volumes and performs functional treatment planning by incorporation of ventilation data from 4D-CT.</p> <p>Materials and methods</p> <p>Eleven patients were included in this retrospective study. Ventilation was calculated using 4D-CT. Two treatment plans were generated for each case, the first one without the incorporation of the ventilation and the second with it. The dose of the first plans was overlapped with the ventilation and analyzed. Highly-functional regions were avoided in the second treatment plans.</p> <p>Results</p> <p>For small targets in the first plans (PTV < 400 cc, 6 cases), all V5, V20 and the mean lung dose values for the highly-functional regions were lower than that of the total lung. For large targets, two out of five cases had higher V5 and V20 values for the highly-functional regions. All the second plans were within constraints.</p> <p>Conclusion</p> <p>Radiation treatments affect functional lung more seriously in large tumor cases. With compromise of dose to other critical organs, functional treatment planning to reduce dose in highly-functional lung volumes can be achieved</p
    corecore