82 research outputs found

    Diagnostic accuracy of contrast-enhanced MR angiography in severe carotid stenosis: meta-analysis with metaregression of different techniques

    Get PDF
    Contrast-enhanced magnetic resonance angiography (CE-MRA) has become a well-established noninvasive imaging method for the assessment of severe carotid stenosis (70–99% by NASCET criteria). However, CE-MRA is not a standardised technique, but encompasses different concurrent techniques. This review analyses possible differences. A bivariate random effects meta-analysis of 17 primary diagnostic accuracy studies confirmed a high pooled sensitivity of 94.3% and specificity of 93.0% for carotid CE-MRA in severe carotid stenosis. Sensitivity was fairly uniform among the studies, while specificity showed significant variation (I2 = 73%). Metaregressions found significant differences for specificity with two covariates: specificity was higher when using not only maximum intensity projection (MIP) images, but also three-dimensional (3D) images (P = 0.01). Specificity was also higher with electronic images than with hardcopies (P = 0.02). The timing technique (bolus-timed, fluoroscopically triggered or time-resolved) did not result in any significant differences in diagnostic accuracy. Some nonsignificant trends were found for the percentages of severe carotid disease, acquisition time and voxel size. In conclusion, in CE-MRA of severe carotid stenosis the three major timing techniques yield comparably high diagnostic accuracy, electronic images are more specific than hardcopies, and 3D images should be used in addition to MIP images to increase the specificity

    Whole shaft visibility and mechanical performance for active MR catheters using copper-nitinol braided polymer tubes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Catheter visualization and tracking remains a challenge in interventional MR.</p> <p>Active guidewires can be made conspicuous in "profile" along their whole shaft exploiting metallic core wire and hypotube components that are intrinsic to their mechanical performance. Polymer-based catheters, on the other hand, offer no conductive medium to carry radio frequency waves. We developed a new "active" catheter design for interventional MR with mechanical performance resembling braided X-ray devices. Our 75 cm long hybrid catheter shaft incorporates a wire lattice in a polymer matrix, and contains three distal loop coils in a flexible and torquable 7Fr device. We explored the impact of braid material designs on radiofrequency and mechanical performance.</p> <p>Results</p> <p>The incorporation of copper wire into in a superelastic nitinol braided loopless antenna allowed good visualization of the whole shaft (70 cm) <it>in vitro </it>and <it>in vivo </it>in swine during real-time MR with 1.5 T scanner. Additional distal tip coils enhanced tip visibility. Increasing the copper:nitinol ratio in braiding configurations improved flexibility at the expense of torquability. We found a 16-wire braid of 1:1 copper:nitinol to have the optimum balance of mechanical (trackability, flexibility, torquability) and antenna (signal attenuation) properties. With this configuration, the temperature increase remained less than 2Β°C during real-time MR within 10 cm horizontal from the isocenter. The design was conspicuous <it>in vitro </it>and <it>in vivo</it>.</p> <p>Conclusion</p> <p>We have engineered a new loopless antenna configuration that imparts interventional MR catheters with satisfactory mechanical and imaging characteristics. This compact loopless antenna design can be generalized to visualize the whole shaft of any general-purpose polymer catheter to perform safe interventional procedures.</p

    Effectiveness and acceptability of progestogens in combined oral contraceptives – a systematic review

    Get PDF
    BACKGROUND: The progestogen component of oral contraceptives (OCs) has undergone changes since it was recognized that their chemical structure can influence the spectrum of minor adverse and beneficial effects. METHODS: The objective of this review was to evaluate currently available low-dose OCs containing ethinylestradiol and different progestogens in terms of contraceptive effectiveness, cycle control, side effects and continuation rates. The Cochrane Controlled Trials Register, MEDLINE and EMBASE databases were searched. Randomized trials reporting clinical outcomes were considered for inclusion and were assessed for methodological quality and validity. RESULTS: Twenty–two trials were included in the review. Eighteen were sponsored by pharmaceutical companies and in only 5 there was an attempt for blinding. Most comparisons between different interventions included one to three trials, involving usually less than 500 women. Discontinuation was less with second-generation progestogens compared to first–generation (RR 0.79; 95% CI 0.69–0.91). Cycle control appeared to be better with second-compared to first-generation progestogens for both, mono-and triphasic preparations (RR 0.69; 95% CI 0.52–0.91) and (RR 0.61; 95% CI 0.43–0.85), respectively. Intermenstrual bleeding was less with third- compared to second-generation pills (RR 0.71; 95% CI 0.55–0.91). Contraceptive effectiveness of gestodene (GSD) was comparable to that of levonorgestrel (LNG), and had similar pattern of spotting, breakthrough bleeding and absence of withdrawal bleeding). Drospirenone (DRSP) was similar compared to desogestrel (DSG) regarding contraceptive effectiveness, cycle control and side effects. CONCLUSION: The third- and second-generation progestogens are preferred over first generation in all indices of acceptability. Current evidence suggests that GSD is comparable to LNG in terms of contraceptive effectiveness and for most cycle control indices. GSD is also comparable to DSG. DRSP is comparable to DSG. Future research should focus on independently conducted well designed randomized trials comparing particularly the third- with second-generation progestogens

    Pioglitazone Decreases Hepatitis C Viral Load in Overweight, Treatment NaΓ―ve, Genotype 4 Infected-Patients: A Pilot Study

    Get PDF
    Insulin resistance (IR) is induced by chronic hepatitis C virus (HCV) genotypes 1 and 4 infections. It is not known whether drugs that affect IR such as Pioglitazone and Prednisone also affect serum HCV RNA titers independently of PEG-Interferon-Ξ±2/ribavirin treatment. The primary aim was to assess whether Pioglitazone by improving IR and/or inflammation decreases HCV viral load independently of standard of care HCV treatment. A secondary aim was to assess whether Prednisone, a drug that induces insulin resistance and stimulates HCV viral entry and replication in replicon culture systems, increases HCV viral load in this population.We designed a two-arm, parallel Pilot Study of overweight, treatment naΓ―ve genotype 4 HCV-infected patients at a public referral Liver Clinic in Giza, Egypt. The subjects received Pioglitazone (30 mg/day for 14 days) or Prednisone (40 mg/day for 4 days) in a randomized fashion, but the two arms can be considered independent pilot studies. Only changes from baseline within each arm were assessed and no contrasts of the interventions were made, as this was not an aim of the study. Among 105 consecutive HCV genotype 4 patients, 39 were enrolled based on the optimal sample size and power analysis according to the CONSORT statement; 20 to the Pioglitazone group and 19 to the Prednisone group. Pioglitazone was effective in decreasing serum HCV RNA at day-14 (nβ€Š=β€Š10; difference of meansβ€Š=β€Š205,618 IU/ml; 95% CI 26,600 to 384,600; P<0.001). Although Prednisone did increase serum HCV RNA at day-4 (nβ€Š=β€Š10; change from baselineβ€Š=β€Š-42,786 IU/ml; 95% CI -85,500 to -15,700; Pβ€Š=β€Š0.049), the log(10) HCV RNA titers were statistically not different from baseline day-0.This is the first documentation that Pioglitazone decreases the serum HCV RNA titers independently of PEG-Interferon-Ξ±2/ribavirin treatment. The novel findings of our Study provide the foundation for basic and clinical investigations on the molecular mechanisms responsible for the Pioglitazone-induced decrease in HCV genotype 4 RNA titers.ClinicalTrials.gov NCT01157975

    Risk factors for hepatitis C virus infection among blood donors in southern Brazil: a case-control study

    Get PDF
    BACKGROUND: In Brazil, it is estimated that between 2.5 and 4.9% of the general population present anti-hepatitis C virus (HCV) antibodies, which corresponds to as many as 3.9 to 7.6 million chronic carriers. Chronic liver disease is associated with HCV infection in 20% to 58% of the Brazilian patients. The objective of this case-control study was to investigate the risk factors for presence of anti-HCV antibody in blood donors in southern Brazil. METHODS: One hundred and seventy eight blood donors with two positive ELISA results for anti-HCV were cases, and 356 controls tested negative. A standardized questionnaire was used to collect data concerning demographic and socioeconomic aspects, history of previous hepatitis infection, social and sexual behaviors, and number of donations. Variables were grouped into sets of hierarchical categories. Cases and controls were compared using logistic regression, odds ratios, and 95% confidence intervals. The statistical significance of the associations was assessed through likelihood ratio tests based on a P value < 0.05. RESULTS: The prevalence of anti-HCV among blood donors was 1.1%. Most of the donors were white and males. In the multivariate analysis, independent predictors of anti-HCV positivity were: intravenous drug use, blood transfusion >10 years earlier, having had two to four sexually transmitted diseases, incarceration, tattooing, sex with a hepatitis B or C virus carrier or with intravenous drug users. CONCLUSION: Intravenous drug use, blood transfusion, and tattooing were the main risk factors for anti-HCV positivity among blood donors from southern Brazil, but sexual HCV transmission should also be considered

    AMP-Activated Kinase Restricts Rift Valley Fever Virus Infection by Inhibiting Fatty Acid Synthesis

    Get PDF
    The cell intrinsic innate immune responses provide a first line of defense against viral infection, and often function by targeting cellular pathways usurped by the virus during infection. In particular, many viruses manipulate cellular lipids to form complex structures required for viral replication, many of which are dependent on de novo fatty acid synthesis. We found that the energy regulator AMPK, which potently inhibits fatty acid synthesis, restricts infection of the Bunyavirus, Rift Valley Fever Virus (RVFV), an important re-emerging arthropod-borne human pathogen for which there are no effective vaccines or therapeutics. We show restriction of RVFV both by AMPK and its upstream activator LKB1, indicating an antiviral role for this signaling pathway. Furthermore, we found that AMPK is activated during RVFV infection, leading to the phosphorylation and inhibition of acetyl-CoA carboxylase, the first rate-limiting enzyme in fatty acid synthesis. Activating AMPK pharmacologically both restricted infection and reduced lipid levels. This restriction could be bypassed by treatment with the fatty acid palmitate, demonstrating that AMPK restricts RVFV infection through its inhibition of fatty acid biosynthesis. Lastly, we found that this pathway plays a broad role in antiviral defense since additional viruses from disparate families were also restricted by AMPK and LKB1. Therefore, AMPK is an important component of the cell intrinsic immune response that restricts infection through a novel mechanism involving the inhibition of fatty acid metabolism
    • …
    corecore