10 research outputs found

    The sine-Gordon model with integrable defects revisited

    Get PDF
    Application of our algebraic approach to Liouville integrable defects is proposed for the sine-Gordon model. Integrability of the model is ensured by the underlying classical r-matrix algebra. The first local integrals of motion are identified together with the corresponding Lax pairs. Continuity conditions imposed on the time components of the entailed Lax pairs give rise to the sewing conditions on the defect point consistent with Liouville integrability.Comment: 24 pages Latex. Minor modifications, added comment

    Liouville integrable defects: the non-linear Schrodinger paradigm

    Get PDF
    A systematic approach to Liouville integrable defects is proposed, based on an underlying Poisson algebraic structure. The non-linear Schrodinger model in the presence of a single particle-like defect is investigated through this algebraic approach. Local integrals of motions are constructed as well as the time components of the corresponding Lax pairs. Continuity conditions imposed upon the time components of the Lax pair to all orders give rise to sewing conditions, which turn out to be compatible with the hierarchy of charges in involution. Coincidence of our results with the continuum limit of the discrete expressions obtained in earlier works further confirms our approach.Comment: 22 pages, Latex. Minor misprints correcte

    Tangential beam IMRT versus tangential beam 3D-CRT of the chest wall in postmastectomy breast cancer patients: A dosimetric comparison

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>This study evaluates the dose distribution of reversed planned tangential beam intensity modulated radiotherapy (IMRT) compared to standard wedged tangential beam three-dimensionally planned conformal radiotherapy (3D-CRT) of the chest wall in unselected postmastectomy breast cancer patients</p> <p>Methods</p> <p>For 20 unselected subsequent postmastectomy breast cancer patients tangential beam IMRT and tangential beam 3D-CRT plans were generated for the radiotherapy of the chest wall. The prescribed dose was 50 Gy in 25 fractions. Dose-volume histograms were evaluated for the PTV and organs at risk. Parameters of the dose distribution were compared using the Wilcoxon matched pairs test.</p> <p>Results</p> <p>Tangential beam IMRT statistically significantly reduced the ipsilateral mean lung dose by an average of 21% (1129 cGy versus 1437 cGy). In all patients treated on the left side, the heart volume encompassed by the 70% isodose line (V70%; 35 Gy) was reduced by an average of 43% (5.7% versus 10.6%), and the mean heart dose by an average of 20% (704 cGy versus 877 cGy). The PTV showed a significantly better conformity index with IMRT; the homogeneity index was not significantly different.</p> <p>Conclusions</p> <p>Tangential beam IMRT significantly reduced the dose-volume of the ipsilateral lung and heart in unselected postmastectomy breast cancer patients.</p

    Fuzzy Modeling

    No full text

    Association of environmental markers with childhood type 1 diabetes mellitus revealed by a long questionnaire on early life exposures and lifestyle in a case–control study

    No full text
    corecore