281 research outputs found

    Relationship between FEV1 change and patient-reported outcomes in randomised trials of inhaled bronchodilators for stable COPD: a systematic review.

    Get PDF
    BACKGROUND: Interactions between spirometry and patient-reported outcomes in COPD are not well understood. This systematic review and study-level analysis investigated the relationship between changes in FEV1 and changes in health status with bronchodilator therapy. METHODS: Six databases (to October 2009) were searched to identify studies with long-acting bronchodilator therapy reporting FEV1 and health status, dyspnoea or exacerbations. Mean and standard deviations of treatment effects were extracted for each arm of each study. Relationships between changes in trough FEV1 and outcomes were assessed using correlations and random-effects regression modelling. The primary outcome was St George's Respiratory Questionnaire (SGRQ) total score. RESULTS: Thirty-six studies (≥ 3 months) were included. Twenty-two studies (23,654 patients) with 49 treatment arms each contributing one data point provided SGRQ data. Change in trough FEV1 and change in SGRQ total score were negatively correlated (r = -0.46, p < 0.001); greater increases in FEV1 were associated with greater reductions (improvements) in SGRQ. The correlation strengthened with increasing study duration from 3 to 12 months. Regression modelling indicated that 100 mL increase in FEV1 (change at which patients are more likely to report improvement) was associated with a statistically significant reduction in SGRQ of 2.5 (95% CI 1.9, 3.1), while a clinically relevant SGRQ change (4.0) was associated with 160.6 (95% CI 129.0, 211.6) mL increase in FEV1. The association between change in FEV1 and other patient-reported outcomes was generally weak. CONCLUSIONS: Our analyses indicate, at a study level, that improvement in mean trough FEV1 is associated with proportional improvements in health status

    The effect of aclidinium bromide on daily respiratory symptoms of COPD, measured using the Evaluating Respiratory Symptoms in COPD (E-RS: COPD) diary: pooled analysis of two 6-month Phase III studies.

    Get PDF
    BACKGROUND: Reducing the severity of respiratory symptoms is a key goal in the treatment of chronic obstructive pulmonary disease (COPD). We evaluated the effect of aclidinium bromide 400 μg twice daily (BID) on respiratory symptoms, assessed using the Evaluating Respiratory Symptoms in COPD (E-RS(™): COPD) scale (formerly EXACT-RS). METHODS: Data were pooled from the aclidinium 400 μg BID and placebo arms of two 24-week, double-blind, randomized Phase III studies evaluating aclidinium monotherapy (ATTAIN) or combination therapy (AUGMENT COPD I) in patients with moderate to severe airflow obstruction. Patients were stratified by Global initiative for chronic Obstructive Lung Disease (GOLD) Groups A-D. Change from baseline in E-RS scores, proportion of responders (patients achieving pre-defined improvements in E-RS scores), and net benefit (patients who improved minus patients who worsened) were analyzed. RESULTS: Of 1210 patients, 1167 had data available for GOLD classification. Mean (standard deviation) age was 63.2 (8.6) years, 60.7 % were male, and mean post-bronchodilator forced expiratory volume in 1 s was 54.4 % predicted. Compared with placebo, aclidinium 400 μg BID significantly improved RS-Total (2.38 units vs 0.79 units, p < 0.001) and domain scores (all p < 0.001) at Week 24, and doubled the likelihood of being an RS-Total score responder (p < 0.05), irrespective of GOLD group. The net benefit for RS-Total (Overall: 56.9 % vs 19.4 %; A + C: 65.7 % vs 6.3 %; B + D: 56.0 % vs 20.8 %, for aclidinium 400 μg BID and placebo respectively; all p < 0.05) and domain scores (all p < 0.05) was significantly greater with aclidinium compared with placebo, in both GOLD Groups A + C and B + D. CONCLUSIONS: Aclidinium 400 μg BID significantly improved respiratory symptoms regardless of the patients' level of symptoms at baseline. Net treatment benefit was similar in patients with low or high levels of symptoms. TRIAL REGISTRATION: ATTAIN (ClinicalTrials.gov identifier: NCT01001494 ) and AUGMENT COPD I (ClinicalTrials.gov identifier: NCT01437397 )

    Efficacy and safety of once-daily aclidinium in chronic obstructive pulmonary disease

    Get PDF
    BACKGROUND: The long-term efficacy and safety of aclidinium bromide, a novel, long-acting muscarinic antagonist, were investigated in patients with moderate to severe chronic obstructive pulmonary disease (COPD). METHODS: In two double-blind, 52-week studies, ACCLAIM/COPD I (n=843) and II (n=804), patients were randomised to inhaled aclidinium 200 μg or placebo once-daily. Patients were required to have a post-bronchodilator forced expiratory volume in 1 second (FEV1)/forced vital capacity ratio of ≤70% and FEV1<80% of the predicted value. The primary endpoint was trough FEV1 at 12 and 28 weeks. Secondary endpoints were health status measured by St George's Respiratory Questionnaire (SGRQ) and time to first moderate or severe COPD exacerbation. RESULTS: At 12 and 28 weeks, aclidinium improved trough FEV1 versus placebo in ACCLAIM/COPD I (by 61 and 67 mL; both p<0.001) and ACCLAIM/COPD II (by 63 and 59 mL; both p<0.001). More patients had a SGRQ improvement≥4 units at 52 weeks with aclidinium versus placebo in ACCLAIM/COPD I (48.1% versus 39.5%; p=0.025) and ACCLAIM/COPD II (39.0% versus 32.8%; p=0.074). The time to first exacerbation was significantly delayed by aclidinium in ACCLAIM/COPD II (hazard ratio [HR] 0.7; 95% confidence interval [CI] 0.55 to 0.92; p=0.01), but not ACCLAIM/COPD I (HR 1.0; 95% CI 0.72 to 1.33; p=0.9). Adverse events were minor in both studies. CONCLUSION: Aclidinium is effective and well tolerated in patients with moderate to severe COPD

    Efficacy and safety of indacaterol 150 μg once-daily in COPD: a double-blind, randomised, 12-week study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Indacaterol is a novel, once-daily (o.d.) inhaled, long-acting <it>β</it><sub>2</sub>-agonist in development for chronic obstructive pulmonary disease (COPD). This 12-week, double-blind study compared the efficacy, safety, and tolerability of indacaterol to that of placebo in patients with moderate-to-severe COPD.</p> <p>Methods</p> <p>Efficacy variables included 24-h trough FEV<sub>1 </sub>(mean of 23 h 10 min and 23 h 45 min post-dose) at Week 12 (primary endpoint) and after Day 1, and the percentage of COPD days with poor control (i.e., worsening symptoms). Safety was assessed by adverse events (AEs), mean serum potassium and blood glucose, QTc (Fridericia), and vital signs.</p> <p>Results</p> <p>Patients were randomised (n = 416, mean age 63 years) to receive either indacaterol 150 <it>μ</it>g o.d. (n = 211) or placebo (n = 205) via a single-dose dry-powder inhaler; 87.5% completed the study. Trough FEV<sub>1 </sub>(LSM ± SEM) at Week 12 was 1.48 ± 0.018 L for indacaterol and 1.35 ± 0.019 L for placebo, a clinically relevant difference of 130 ± 24 mL (p < 0.001). Trough FEV<sub>1 </sub>after one dose was significantly higher with indacaterol than placebo (p < 0.001). Indacaterol demonstrated significantly higher peak FEV<sub>1 </sub>than placebo, both on Day 1 and at Week 12, with indacaterol-placebo differences (LSM ± SEM) of 190 ± 28 (p < 0.001) and 160 ± 28 mL (p < 0.001), respectively. Standardised AUC measurements for FEV<sub>1 </sub>(between 5 min and 4 h, 5 min and 1 h, and 1 and 4 h post-dose) at Week 12 were all significantly greater with indacaterol than placebo (p < 0.001), with LSM (± SEM) differences of 170 ± 24, 180 ± 24, and 170 ± 24 mL, respectively. Indacaterol significantly reduced the percentage of days of poor control versus placebo by 22.5% (p < 0.001) and was also associated with significantly reduced use of rescue medication (p < 0.001). The overall rates of AEs were comparable between the groups (indacaterol 49.3%, placebo 46.8%), with the most common AEs being COPD worsening (indacaterol 8.5%, placebo 12.2%) and cough (indacaterol 6.2%, placebo 7.3%). One patient died in the placebo group. Serum potassium and blood glucose levels did not differ significantly between the two groups, and no patient had QTc >500 ms.</p> <p>Conclusions</p> <p>Indacaterol 150 <it>μ</it>g o.d. provided clinically significant and sustained bronchodilation, reduced rescue medication use, and had a safety and tolerability profile similar to placebo.</p> <p>Trial registration</p> <p>NCT00624286</p

    Characterization of Particles in Protein Solutions: Reaching the Limits of Current Technologies

    Get PDF
    Recent publications have emphasized the lack of characterization methods available for protein particles in a size range comprised between 0.1 and 10 μm and the potential risk of immunogenicity associated with such particles. In the present paper, we have investigated the performance of light obscuration, flow microscopy, and Coulter counter instruments for particle counting and sizing in protein formulations. We focused on particles 2–10 μm in diameter and studied the effect of silicon oil droplets originating from the barrel of pre-filled syringes, as well as the effect of high protein concentrations (up to 150 mg/ml) on the accuracy of particle characterization. Silicon oil was demonstrated to contribute significantly to the particle counts observed in pre-filled syringes. Inconsistent results were observed between different protein concentrations in the range 7.5–150 mg/ml for particles <10 μm studied by optical techniques (light obscuration and flow microscopy). However, the Coulter counter measurements were consistent across the same studied concentration range but required sufficient solution conductivity from the formulation buffer or excipients. Our results show that currently available technologies, while allowing comparisons between samples of a given protein at a fixed concentration, may be unable to measure particle numbers accurately in a variety of protein formulations, e.g., at high concentration in sugar-based formulations

    Correlating changes in lung function with patient outcomes in chronic obstructive pulmonary disease: a pooled analysis

    Get PDF
    Background Relationships between improvements in lung function and other clinical outcomes in chronic obstructive pulmonary disease (COPD) are not documented extensively. We examined whether changes in trough forced expiratory volume in 1 second (FEV1) are correlated with changes in patient-reported outcomes. Methods Pooled data from three indacaterol studies (n = 3313) were analysed. Means and responder rates for outcomes including change from baseline in Transition Dyspnoea Index (TDI), St. George's Respiratory Questionnaire (SGRQ) scores (at 12, 26 and 52 weeks), and COPD exacerbation frequency (rate/year) were tabulated across categories of ΔFEV1. Also, generalised linear modelling was performed adjusting for covariates such as baseline severity and inhaled corticosteroid use. Results With increasing positive ΔFEV1, TDI and ΔSGRQ improved at all timepoints, exacerbation rate over the study duration declined (P < 0.001). Individual-level correlations were 0.03-0.18, but cohort-level correlations were 0.79-0.95. At 26 weeks, a 100 ml increase in FEV1 was associated with improved TDI (0.46 units), ΔSGRQ (1.3-1.9 points) and exacerbation rate (12% decrease). Overall, adjustments for baseline covariates had little impact on the relationship between ΔFEV1 and outcomes. Conclusions These results suggest that larger improvements in FEV1 are likely to be associated with larger patient-reported benefits across a range of clinical outcomes

    Fluorescence Single Particle Tracking for the Characterization of Submicron Protein Aggregates in Biological Fluids and Complex Formulations

    Get PDF
    To evaluate the potential of fluorescence single particle tracking (fSPT) for the characterization of submicron protein aggregates in human serum, plasma and formulations containing human serum albumin (HSA). A monoclonal IgG was covalently labeled with a fluorescent dye and cross-linked with glutaraldehyde. IgG aggregates and fluorescent beads of 0.1 mu m (control) were diluted in buffer, serum and plasma, and their size distributions were analyzed by fSPT and nanoparticle tracking analysis (NTA). In a separate experiment, IgG and HSA, fluorescently labeled with different dyes, were mixed and subjected to heat stress. The stressed sample was analyzed by fSPT using a dual color mode and by NTA. The accuracy and precision of fSPT proved to be comparable to NTA. fSPT was able to successfully measure all the samples in buffer, serum and plasma. The average size of the cross-linked protein aggregates showed a slight increase in biological fluids. Moreover, fSPT analysis showed that a significant proportion of the aggregates formed by subjecting an IgG/HSA mixture to heat stress were composed of both proteins. fSPT is a powerful technique for the characterization of submicron protein aggregates in biological fluids and complex formulations
    corecore