98 research outputs found

    The first multi-wavelength campaign of AXP 4U 0142+61 from radio to hard X-rays

    Get PDF
    For the first time a quasi-simultaneous multi-wavelength campaign has been performed on an Anomalous X-ray Pulsar from the radio to the hard X-ray band. 4U 0142+61 was an INTEGRAL target for 1 Ms in July 2005. During these observations it was also observed in the X-ray band with Swift and RXTE, in the optical and NIR with Gemini North and in the radio with the WSRT. In this paper we present the source-energy distribution. The spectral results obtained in the individual wave bands do not connect smoothly; apparently components of different origin contribute to the total spectrum. Remarkable is that the INTEGRAL hard X-ray spectrum (power-law index 0.79 +/- 0.10) is now measured up to an energy of ~230 keV with no indication of a spectral break. Extrapolation of the INTEGRAL power-law spectrum to lower energies passes orders of magnitude underneath the NIR and optical fluxes, as well as the low ~30 microJy (2 sigma) upper limit in the radio band.Comment: 6 pages, 1 figure. To be published in the proceedings of the conference "Isolated Neutron Stars: from the Interior to the Surface" (April 24-28, 2006, London, UK), eds. S. Zane, R. Turolla and D. Pag

    Active vibration control using mechanical and electrical analogies

    Get PDF
    Mechanical-electrical analogous circuit models are widely used in electromechanical system design as they represent the function of a coupled electrical and mechanical system using an equivalent electrical system. This research uses electrical circuits to establish a discussion of simple active vibration control principles using two scenarios: an active vibration isolation system and an active dynamic vibration absorber (DVA) using a voice coil motor (VCM) actuator. Active control laws such as gain scheduling are intuitively explained using circuit analysis techniques. Active vibration control approaches are typically constraint by electrical power requirements. The electrical analogous is a fast approach for specifying power requirements on the experimental test platform which is based on a vibration shaker that provides the based excitation required for the single Degree- of-Freedom (1DoF) vibration model under study

    HUMeral Shaft Fractures: MEasuring Recovery after Operative versus Non-operative Treatment (HUMMER): A multicenter comparative observational study

    Get PDF
    Background: Fractures of the humeral shaft are associated with a profound temporary (and in the elderly sometimes even permanent) impairment of independence and quality of life. These fractures can be treated operatively or non-operatively, but the optimal tailored treatment is an unresolved problem. As no high-quality comparative randomized or observational studies are available, a recent Cochrane review concluded there is no evidence of sufficient scientific quality available to inform the decision to operate or not. Since randomized controlled trials for this injury have shown feasibility issues, this study is designed to provide the best achievable evidence to answer this unresolved problem. The primary aim of this study is to evaluate functional recovery after operative versus non-operative treatment in adult patients who sustained a humeral shaft fracture. Secondary aims include the effect of treatment on pain, complications, generic health-related quality of life, time to resumption of activities of daily living and work, and cost-effectiveness. The main hypothesis is that operative treatment will result in faster recovery. Methods/design. The design of the study will be a multicenter prospective observational study of 400 patients who have sustained a humeral shaft fracture, AO type 12A or 12B. Treatment decision (i.e., operative or non-operative) will be left to the discretion of the treating surgeon. Critical elements of treatment will be registered and outcome will be monitored at regular intervals over the subsequent 12 months. The primary outcome measure is the Disabilities of the Arm, Shoulder, and Hand score. Secondary outcome measures are the Constant score, pain level at both sides, range of motion of the elbow and shoulder joint at both sides, radiographic healing, rate of complications and (secondary) interventions, health-related quality of life (Short-Form 36 and EuroQol-5D), time to resumption of ADL/work, and cost-effectiveness. Data will be analyzed using univariate and multivariable analyses (including mixed effects regression analysis). The cost-effectiveness analysis will be performed from a societal perspective. Discussion. Successful completion of this trial will provide evidence on the effectiveness of operative versus non-operative treatment of patients with a humeral shaft fracture. Trial registration. The trial is registered at the Netherlands Trial Register (NTR3617)

    Reliability and Reproducibility of the OTA/AO Classification for Humeral Shaft Fractures

    Get PDF
    Objectives: This study aimed to determine interobserver reliability and intraobserver reproducibility of the OTA/AO classification for humeral shaft fractures, and to evaluate differences between fracture types, fracture groups, and surgical specializations. Methods: Thirty observers (25 orthopaedic trauma surgeons and 5 general orthopaedic surgeons) independently classified 90 humeral shaft fractures according to the OTA/AO classification. Patients of 16 years and older were included. Periprosthetic, recurrent, and pathological fractures were excluded. Radiographs were provided in random order, and observers were blinded to clinical information. To determine intraobserver agreement, radiographs were reviewed again after 2 months in a different random order. Agreement was assessed using kappa statistics. Results: Interobserver agreement for the 3 fracture types was moderate (κ = 0.60; 0.59-0.61). It was substantial for type A (κ = 0.77; 0.70-0.84) and moderate for type B (κ = 0.52; 0.46-0.58) and type C fractures (κ = 0.46; 0.42-0.50). Interobserver agreement for the 9 fracture groups was moderate (κ = 0.48; 95% CI, 0.48-0.48). Orthopaedic trauma surgeons had better overall agreement for fracture types, and general orthopaedic surgeons had better overall agreement for fracture groups. Observers classified 64% of fractures identically in both rounds. Intraobserver agreement was substantial for the 3 types (κ = 0.80; 0.77-0.81) and 9 groups (κ = 0.80; 0.77-0.82). Intraobserver agreement showed no differences between surgical disciplines. Conclusions: The OTA/AO classification for humeral shaft fractures has a moderate interobserver and substantial intraobserver agreement for fracture types and groups

    Endometrial scratching in women with one failed IVF/ICSI cycle-outcomes of a randomised controlled trial (SCRaTCH)

    Get PDF
    STUDY QUESTION: Does endometrial scratching in women with one failed IVF/ICSI treatment affect the chance of a live birth of the subsequent fresh IVF/ICSI cycle? SUMMARY ANSWER: In this study, 4.6% more live births were observed in the scratch group, with a likely certainty range between -0.7% and +9.9%. WHAT IS KNOWN ALREADY: Since the first suggestion that endometrial scratching might improve embryo implantation during IVF/ICSI, many clinical trials have been conducted. However, due to limitations in sample size and study quality, it remains unclear whether endometrial scratching improves IVF/ICSI outcomes. STUDY DESIGN, SIZE, DURATION: The SCRaTCH trial was a non-blinded randomised controlled trial in women with one unsuccessful IVF/ICSI cycle and assessed whether a single endometrial scratch using an endometrial biopsy catheter would lead to a higher live birth rate after the subsequent IVF/ICSI treatment compared to no scratch. The study took place in 8 academic and 24 general hospitals. Participants were randomised between January 2016 and July 2018 by a web-based randomisation programme. Secondary outcomes included cumulative 12-month ongoing pregnancy leading to live birth rate. PARTICIPANTS/MATERIALS, SETTING, METHODS: Women with one previous failed IVF/ICSI treatment and planning a second fresh IVF/ICSI treatment were eligible. In total, 933 participants out of 1065 eligibles were included (participation rate 88%). MAIN RESULTS AND THE ROLE OF CHANCE: After the fresh transfer, 4.6% more live births were observed in the scratch compared to control group (110/465 versus 88/461, respectively, risk ratio (RR) 1.24 [95% CI 0.96-1.59]). These data are consistent with a true difference of between -0.7% and +9.9% (95% CI), indicating that while the largest proportion of the 95% CI is positive, scratchin

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    Advanced strength of materials

    No full text
    ix+379hlm.;23c

    Mechanics

    No full text
    IX+459hlm.;20c
    corecore