24 research outputs found

    Distribution and outcomes of a phenotype-based approach to guide COPD management: Results from the CHAIN cohort

    Get PDF
    Rationale: The Spanish guideline for COPD (GesEPOC) recommends COPD treatment according to four clinical phenotypes: non-exacerbator phenotype with either chronic bronchitis or emphysema (NE), asthma-COPD overlap syndrome (ACOS), frequent exacerbator phenotype with emphysema (FEE) or frequent exacerbator phenotype with chronic bronchitis (FECB). However, little is known on the distribution and outcomes of the four suggested phenotypes. Objective: We aimed to determine the distribution of these COPD phenotypes, and their relation with one-year clinical outcomes. Methods: We followed a cohort of well-characterized patients with COPD up to one-year. Baseline characteristics, health status (CAT), BODE index, rate of exacerbations and mortality up to one year of follow-up were compared between the four phenotypes. Results: Overall, 831 stable COPD patients were evaluated. They were distributed as NE, 550 (66.2%); ACOS, 125 (15.0%); FEE, 38 (4.6%); and FECB, 99 (11.9%); additionally 19 (2.3%) COPD patients with frequent exacerbations did not fulfill the criteria for neither FEE nor FECB. At baseline, there were significant differences in symptoms, FEV1 and BODE index (all p<0.05). The FECB phenotype had the highest CAT score (17.1±8.2, p<0.05 compared to the other phenotypes). Frequent exacerbator groups (FEE and FECB) were receiving more pharmacological treatment at baseline, and also experienced more exacerbations the year after (all p<0.05) with no differences in one-year mortality. Most of NE (93%) and half of exacerbators were stable after one year. Conclusions: There is an uneven distribution of COPD phenotypes in stable COPD patients, with significant differences in demographics, patient-centered outcomes and health care resources use

    Effectiveness and Safety of the Sequential Use of a Second and Third Anti-TNF Agent in Patients with Inflammatory Bowel Disease: Results from the Eneida Registry

    Get PDF
    Background: The effectiveness of the switch to another anti-tumor necrosis factor (anti-TNF) agent is not known. The aim of this study was to analyze the effectiveness and safety of treatment with a second and third anti-TNF drug after intolerance to or failure of a previous anti-TNF agent in inflammatory bowel disease (IBD) patients. Methods: We included patients diagnosed with IBD from the ENEIDA registry who received another anti-TNF after intolerance to or failure of a prior anti-TNF agent. Results: A total of 1122 patients were included. In the short term, remission was achieved in 55% of the patients with the second anti-TNF. The incidence of loss of response was 19% per patient-year with the second anti-TNF. Combination therapy (hazard ratio [HR], 2.4; 95% confidence interval [CI], 1.8-3; P < 0.0001) and ulcerative colitis vs Crohn''s disease (HR, 1.6; 95% CI, 1.1-2.1; P = 0.005) were associated with a higher probability of loss of response. Fifteen percent of the patients had adverse events, and 10% had to discontinue the second anti-TNF. Of the 71 patients who received a third anti-TNF, 55% achieved remission. The incidence of loss of response was 22% per patient-year with a third anti-TNF. Adverse events occurred in 7 patients (11%), but only 1 stopped the drug. Conclusions: Approximately half of the patients who received a second anti-TNF achieved remission; nevertheless, a significant proportion of them subsequently lost response. Combination therapy and type of IBD were associated with loss of response. Remission was achieved in almost 50% of patients who received a third anti-TNF; nevertheless, a significant proportion of them subsequently lost response

    Evolution of the use of corticosteroids for the treatment of hospitalised COVID-19 patients in Spain between March and November 2020: SEMI-COVID national registry

    Get PDF
    Objectives: Since the results of the RECOVERY trial, WHO recommendations about the use of corticosteroids (CTs) in COVID-19 have changed. The aim of the study is to analyse the evolutive use of CTs in Spain during the pandemic to assess the potential influence of new recommendations. Material and methods: A retrospective, descriptive, and observational study was conducted on adults hospitalised due to COVID-19 in Spain who were included in the SEMI-COVID- 19 Registry from March to November 2020. Results: CTs were used in 6053 (36.21%) of the included patients. The patients were older (mean (SD)) (69.6 (14.6) vs. 66.0 (16.8) years; p < 0.001), with hypertension (57.0% vs. 47.7%; p < 0.001), obesity (26.4% vs. 19.3%; p < 0.0001), and multimorbidity prevalence (20.6% vs. 16.1%; p < 0.001). These patients had higher values (mean (95% CI)) of C-reactive protein (CRP) (86 (32.7-160) vs. 49.3 (16-109) mg/dL; p < 0.001), ferritin (791 (393-1534) vs. 470 (236- 996) µg/dL; p < 0.001), D dimer (750 (430-1400) vs. 617 (345-1180) µg/dL; p < 0.001), and lower Sp02/Fi02 (266 (91.1) vs. 301 (101); p < 0.001). Since June 2020, there was an increment in the use of CTs (March vs. September; p < 0.001). Overall, 20% did not receive steroids, and 40% received less than 200 mg accumulated prednisone equivalent dose (APED). Severe patients are treated with higher doses. The mortality benefit was observed in patients with oxygen saturation </=90%. Conclusions: Patients with greater comorbidity, severity, and inflammatory markers were those treated with CTs. In severe patients, there is a trend towards the use of higher doses. The mortality benefit was observed in patients with oxygen saturation </=90%

    Seguimiento de las guías españolas para el manejo del asma por el médico de atención primaria: un estudio observacional ambispectivo

    Get PDF
    Objetivo Evaluar el grado de seguimiento de las recomendaciones de las versiones de la Guía española para el manejo del asma (GEMA 2009 y 2015) y su repercusión en el control de la enfermedad. Material y métodos Estudio observacional y ambispectivo realizado entre septiembre del 2015 y abril del 2016, en el que participaron 314 médicos de atención primaria y 2.864 pacientes. Resultados Utilizando datos retrospectivos, 81 de los 314 médicos (25, 8% [IC del 95%, 21, 3 a 30, 9]) comunicaron seguir las recomendaciones de la GEMA 2009. Al inicio del estudio, 88 de los 314 médicos (28, 0% [IC del 95%, 23, 4 a 33, 2]) seguían las recomendaciones de la GEMA 2015. El tener un asma mal controlada (OR 0, 19, IC del 95%, 0, 13 a 0, 28) y presentar un asma persistente grave al inicio del estudio (OR 0, 20, IC del 95%, 0, 12 a 0, 34) se asociaron negativamente con tener un asma bien controlada al final del seguimiento. Por el contrario, el seguimiento de las recomendaciones de la GEMA 2015 se asoció de manera positiva con una mayor posibilidad de que el paciente tuviera un asma bien controlada al final del periodo de seguimiento (OR 1, 70, IC del 95%, 1, 40 a 2, 06). Conclusiones El escaso seguimiento de las guías clínicas para el manejo del asma constituye un problema común entre los médicos de atención primaria. Un seguimiento de estas guías se asocia con un control mejor del asma. Existe la necesidad de actuaciones que puedan mejorar el seguimiento por parte de los médicos de atención primaria de las guías para el manejo del asma. Objective: To assess the degree of compliance with the recommendations of the 2009 and 2015 versions of the Spanish guidelines for managing asthma (Guía Española para el Manejo del Asma [GEMA]) and the effect of this compliance on controlling the disease. Material and methods: We conducted an observational ambispective study between September 2015 and April 2016 in which 314 primary care physicians and 2864 patients participated. Results: Using retrospective data, we found that 81 of the 314 physicians (25.8%; 95% CI 21.3–30.9) stated that they complied with the GEMA2009 recommendations. At the start of the study, 88 of the 314 physicians (28.0%; 95% CI 23.4–33.2) complied with the GEMA2015 recommendations. Poorly controlled asthma (OR, 0.19; 95% CI 0.13–0.28) and persistent severe asthma at the start of the study (OR, 0.20; 95% CI 0.12–0.34) were negatively associated with having well-controlled asthma by the end of the follow-up. In contrast, compliance with the GEMA2015 recommendations was positively associated with a greater likelihood that the patient would have well-controlled asthma by the end of the follow-up (OR, 1.70; 95% CI 1.40–2.06). Conclusions: Low compliance with the clinical guidelines for managing asthma is a common problem among primary care physicians. Compliance with these guidelines is associated with better asthma control. Actions need to be taken to improve primary care physician compliance with the asthma management guidelines

    Nuevas Terapias: Estimulación eléctrica percutánea en dolor lumbar y cervical

    No full text
    The high incidence and prevalence of low back and cervical pain in industrialized societies ensues its importance for health systems. These conditions generate a high consumption of health resources and a significant loss of working hours. Among the therapeutic options for the treatment of these processes, Percutaneous Neuromodulation Therapy (PNT) is an innovative procedure within the range of therapies available. PNT, unlike other neuromodulation systems, is less invasive and has a considerable safety and efficacy profile. A review of the relevant published data regarding this technique and a brief report on its preliminary results for its use in our country are made.La elevada incidencia y prevalencia del dolor lumbar y del cervical en las sociedades industrializadas hace que se consideren patologías de primer orden en los sistemas sanitarios, ya que además del elevado consumo de recursos sanitarios generan una importante pérdida de horas laborales. Son múltiples las opciones terapéuticas para el tratamiento de estos procesos, planteándose la estimulación eléctrica percutánea (PNT) como una novedad dentro del abanico de posibilidades de tratamiento. Como característica diferencial con otros sistemas de neuromodulación resulta menos invasiva y con un perfil de seguridad y eficacia realmente notable. Presentamos una recopilación de los datos publicados más relevantes que avalan esta técnica y un breve comentario de los resultados preliminares de su utilización en nuestro país
    corecore