146 research outputs found

    Rotational IMRT techniques compared to fixed gantry IMRT and Tomotherapy: multi-institutional planning study for head-and-neck cases

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recent developments enable to deliver rotational IMRT with standard C-arm gantry based linear accelerators. This upcoming treatment technique was benchmarked in a multi-center treatment planning study against static gantry IMRT and rotational IMRT based on a ring gantry for a complex parotid gland sparing head-and-neck technique.</p> <p>Methods</p> <p>Treatment plans were created for 10 patients with head-and-neck tumours (oropharynx, hypopharynx, larynx) using the following treatment planning systems (TPS) for rotational IMRT: Monaco (ELEKTA VMAT solution), Eclipse (Varian RapidArc solution) and HiArt for the helical tomotherapy (Tomotherapy). Planning of static gantry IMRT was performed with KonRad, Pinnacle and Panther DAO based on step&shoot IMRT delivery and Eclipse for sliding window IMRT. The prescribed doses for the high dose PTVs were 65.1Gy or 60.9Gy and for the low dose PTVs 55.8Gy or 52.5Gy dependend on resection status. Plan evaluation was based on target coverage, conformity and homogeneity, DVHs of OARs and the volume of normal tissue receiving more than 5Gy (V<sub>5Gy</sub>). Additionally, the cumulative monitor units (MUs) and treatment times of the different technologies were compared. All evaluation parameters were averaged over all 10 patients for each technique and planning modality.</p> <p>Results</p> <p>Depending on IMRT technique and TPS, the mean CI values of all patients ranged from 1.17 to 2.82; and mean HI values varied from 0.05 to 0.10. The mean values of the median doses of the spared parotid were 26.5Gy for RapidArc and 23Gy for VMAT, 14.1Gy for Tomo. For fixed gantry techniques 21Gy was achieved for step&shoot+KonRad, 17.0Gy for step&shoot+Panther DAO, 23.3Gy for step&shoot+Pinnacle and 18.6Gy for sliding window.</p> <p>V<sub>5Gy </sub>values were lowest for the sliding window IMRT technique (3499 ccm) and largest for RapidArc (5480 ccm). The lowest mean MU value of 408 was achieved by Panther DAO, compared to 1140 for sliding window IMRT.</p> <p>Conclusions</p> <p>All IMRT delivery technologies with their associated TPS provide plans with satisfying target coverage while at the same time respecting the defined OAR criteria. Sliding window IMRT, RapidArc and Tomo techniques resulted in better target dose homogeneity compared to VMAT and step&shoot IMRT. Rotational IMRT based on C-arm linacs and Tomotherapy seem to be advantageous with respect to OAR sparing and treatment delivery efficiency, at the cost of higher dose delivered to normal tissues. The overall treatment plan quality using Tomo seems to be better than the other TPS technology combinations.</p

    Measurement of E2 Transitions in the Coulomb Dissociation of 8B

    Full text link
    In an effort to understand the implications of Coulomb dissociation experiments for the determination of the 7Be(p,gamma)8B reaction rate, longitudinal momentum distributions of 7Be fragments produced in the Coulomb dissociation of 44 and 81 MeV/nucleon 8B beams on a Pb target were measured. These distributions are characterized by asymmetries interpreted as the result of interference between E1 and E2 transition amplitudes in the Coulomb breakup. At the lower beam energy, both the asymmetries and the measured cross sections are well reproduced by perturbation theory calculations, allowing a determination of the E2 strength.Comment: 8 pages, 3 figure

    Robust signatures of solar neutrino oscillation solutions

    Get PDF
    With the goal of identifying signatures that select specific neutrino oscillation parameters, we test the robustness of global oscillation solutions that fit all the available solar and reactor experimental data. We use three global analysis strategies previously applied by different authors and also determine the sensitivity of the oscillation solutions to the critical nuclear fusion cross section, S_{17}(0), for the production of 8B. The favored solutions are LMA, LOW, and VAC in order of g.o.f. The neutral current to charged current ratio for SNO is predicted to be 3.5 +- 0.6 (1 sigma), which is separated from the no-oscillation value of 1.0 by much more than the expected experimental error. The predicted range of the day-night difference in charged current rates is (8.2 +- 5.2)% and is strongly correlated with the day-night effect for neutrino-electron scattering. A measurement by SNO of either a NC to CC ratio > 3.3 or a day-night difference > 10%, would favor a small region of the currently allowed LMA neutrino parameter space. The global oscillation solutions predict a 7Be neutrino-electron scattering rate in BOREXINO and KamLAND in the range 0.66 +- 0.04 of the BP00 standard solar model rate, a prediction which can be used to test both the solar model and the neutrino oscillation theory. Only the LOW solution predicts a large day-night effect(< 42%) in BOREXINO and KamLAND. For the KamLAND reactor experiment, the LMA solution predicts 0.44 of the standard model rate; we evaluate 1 sigma and 3 sigma uncertainties and the first and second moments of the energy spectrum.Comment: Included predictions for KamLAND reactor experiment and updated to include 1496 days of Super-Kamiokande observation

    Low-lying continuum structures in B8 and Li8 in a microscopic model

    Full text link
    We search for low-lying resonances in the B8 and Li8 nuclei using a microscopic cluster model and a variational scattering method, which is analytically continued to complex energies. After fine-tuning the nucleon-nucleon interaction to get the known 1+ state of B8 at the right energy, we reproduce the known spectra of the studied nuclei. In addition, our model predicts a 1+ state at 1.3 MeV in B8, relative to the Be7+p threshold, whose corresponding pair is situated right at the Li7+n threshold in Li8. Lacking any experimental evidence for the existence of such states, it is presently uncertain whether these structures really exist or they are spurious resonances in our model. We demonstrate that the predicted state in B8, if it exists, would have important consequences for the understanding of the astrophysically important Be7(p,gamma)B8 reaction.Comment: 6 pages with 1 figure. The postscript file and more information are available at http://nova.elte.hu/~csot

    Interatomic potentials for atomistic simulations of the Ti-Al system

    Full text link
    Semi-empirical interatomic potentials have been developed for Al, alpha-Ti, and gamma-TiAl within the embedded atomic method (EAM) by fitting to a large database of experimental as well as ab-initio data. The ab-initio calculations were performed by the linear augmented plane wave (LAPW) method within the density functional theory to obtain the equations of state for a number of crystal structures of the Ti-Al system. Some of the calculated LAPW energies were used for fitting the potentials while others for examining their quality. The potentials correctly predict the equilibrium crystal structures of the phases and accurately reproduce their basic lattice properties. The potentials are applied to calculate the energies of point defects, surfaces, planar faults in the equilibrium structures. Unlike earlier EAM potentials for the Ti-Al system, the proposed potentials provide reasonable description of the lattice thermal expansion, demonstrating their usefulness in the molecular dynamics or Monte Carlo studies at high temperatures. The energy along the tetragonal deformation path (Bain transformation) in gamma-TiAl calculated with the EAM potential is in a fairly good agreement with LAPW calculations. Equilibrium point defect concentrations in gamma-TiAl are studied using the EAM potential. It is found that antisite defects strongly dominate over vacancies at all compositions around stoichiometry, indicating that gamm-TiAl is an antisite disorder compound in agreement with experimental data.Comment: 46 pages, 6 figures (Physical Review B, in press

    DR6 as a Diagnostic and Predictive Biomarker in Adult Sarcoma

    Get PDF
    The Death Receptor 6 (DR6) protein is elevated in the serum of ovarian cancer patients. We tested DR6 serum protein levels as a diagnostic/predictive biomarker in several epithelial tumors and sarcomas.DR6 gene expression profiles were screened in publically available arrays of solid tumors. A quantitative immunofluorescent western blot analysis was developed to test the serum of healthy controls and patients with sarcoma, uterine carcinosarcoma, bladder, liver, and pancreatic carcinomas. Change in DR6 serum levels was used to assay the ability of DR6 to predict the response to therapy of sarcoma patients.DR6 mRNA is highly expressed in all tumor types assayed. Western blot analysis of serum DR6 protein demonstrated high reproducibility (r = 0.97). Compared to healthy donor controls, DR6 serum levels were not elevated in patients with uterine carcinosarcoma, bladder, liver, or pancreatic cancers. Serum DR6 protein levels from adult sarcoma patients were significantly elevated (p<0.001). This was most evident for patients with synovial sarcoma. Change in serum DR6 levels during therapy correlated with clinical benefit from therapy (sensitivity 75%, and positive predictive value 87%).DR6 may be a clinically useful diagnostic and predictive serum biomarker for some adult sarcoma subtypes.Diagnosis of sarcoma can be difficult and can lead to improper management of these cancers. DR6 serum protein may be a tool to aid in the diagnosis of some sarcomatous tumors to improve treatment planning. For patients with advanced disease, rising DR6 levels predict non-response to therapy and may expedite therapeutic decision making and reduce reliance on radiologic imaging
    • …
    corecore