2,697 research outputs found

    Spacecraft redesign to reduce microphonic response of a VCO component

    Get PDF
    Reaction wheel vibration was found to induce out of specification sidebands on the carrier frequencies of some spacecraft components containing mechanical voltage control oscillators (VCOs). Concurrent investigations were performed to redesign the VCOs to reduce their response to the wheel vibration, and to design a reaction wheel isolation system to reduce the vibration input to the affected components. Component level tests indicated that both efforts provided viable solutions. The redesigned VCO will be incorporated into future spacecraft in the series, while affected spacecraft already in production will be retrofitted with the reaction wheel isolation system

    Momentum Regularity and Stability of the Relativistic Vlasov-Maxwell-Boltzmann System

    Full text link
    In the study of solutions to the relativistic Boltzmann equation, their regularity with respect to the momentum variables has been an outstanding question, even local in time, due to the initially unexpected growth in the post-collisional momentum variables which was discovered in 1991 by Glassey & Strauss \cite{MR1105532}. We establish momentum regularity within energy spaces via a new splitting technique and interplay between the Glassey-Strauss frame and the center of mass frame of the relativistic collision operator. In a periodic box, these new momentum regularity estimates lead to a proof of global existence of classical solutions to the two-species relativistic Vlasov-Boltzmann-Maxwell system for charged particles near Maxwellian with hard ball interaction.Comment: 23 pages; made revisions which were suggested by the referee; to appear in Comm. Math. Phy

    Control sideband generation for dual-recycled laser interferometric gravitational wave detectors

    Get PDF
    We present a discussion of the problems associated with generation of multiple control sidebands for length sensing and control of dual-recycled, cavity-enhanced Michelson interferometers and the motivation behind more complicated sideband generation methods. We focus on the Mach–Zehnder interferometer as a topological solution to the problem and present results from tests carried out at the Caltech 40 m prototype gravitational wave detector. The consequences for sensing and control for advanced interferometry are discussed, as are the implications for future interferometers such as Advanced LIGO

    Optimal time-domain combination of the two calibrated output quadratures of GEO 600

    Get PDF
    GEO 600 is an interferometric gravitational wave detector with a 600 m arm-length and which uses a dual-recycled optical configuration to give enhanced sensitivity over certain frequencies in the detection band. Due to the dual-recycling, GEO 600 has two main output signals, both of which potentially contain gravitational wave signals. These two outputs are calibrated to strain using a time-domain method. In order to simplify the analysis of the GEO 600 data set, it is desirable to combine these two calibrated outputs to form a single strain signal that has optimal signal-to-noise ratio across the detection band. This paper describes a time-domain method for doing this combination. The method presented is similar to one developed for optimally combining the outputs of two colocated gravitational wave detectors. In the scheme presented in this paper, some simplifications are made to allow its implementation using time-domain methods

    Experimental demonstration of coupled optical springs

    Get PDF
    Optical rigidity will play an important role in improving the sensitivity of future generations of gravitational wave (GW) interferometers, which employ high laser power in order to reach and exceed the standard quantum limit. Several experiments have demonstrated the combined effect of two optical springs on a single system for very low-weight mirror masses or membranes. In this paper we investigate the complex interactions between multiple optical springs and the surrounding apparatus in a system of comparable dynamics to a large-scale GW detector. Using three 100 g mirrors to form a coupled cavity system capable of sustaining two or more optical springs, we demonstrate a number of different regimes of opto-mechanical rigidity and measurement techniques. Our measurements reveal couplings between each optical spring and the control loops that can affect both the achievable increase in sensitivity and the stability of the system. Hence this work establishes a better understanding of the realisation of these techniques and paves the way to their application in future GW observatories, such as upgrades to Advanced LIGO

    Experimental test of higher-order Laguerre–Gauss modes in the 10 m Glasgow prototype interferometer

    Get PDF
    Brownian noise of dielectric mirror coatings is expected to be one of the limiting noise sources, at the peak sensitivity, of next generation ground based interferometric gravitational wave (GW) detectors. The use of higher-order Laguerre–Gauss (LG) beams has been suggested to reduce the effect of coating thermal noise in future generations of gravitational wave detectors. In this paper we describe the first test of interferometry with higher-order LG beams in an environment similar to a full-scale gravitational wave detector. We compare the interferometric performance of higher-order LG modes and the fundamental mode beams, injected into a 10 m long suspended cavity that features a finesse of 612, a value chosen to be typical of future gravitational wave detectors. We found that the expected mode degeneracy of the injected LG3, 3 beam was resolved into a multiple peak structure, and that the cavity length control signal featured several nearby zero crossings. The break up of the mode degeneracy is due to an astigmatism (defined as |Rcy − Rcx|) of 5.25 ± 0.5 cm on one of our cavity mirrors with a radius of curvature (Rc) of 15 m. This observation agrees well with numerical simulations developed with the FINESSE software. We also report on how these higher-order mode beams respond to the misalignment and mode mismatch present in our 10 m cavity. In general we found the LG3, 3 beam to be considerably more susceptible to astigmatism and mode mismatch than a conventional fundamental mode beam. Therefore the potential application of higher-order Laguerre–Gauss beams in future gravitational wave detectors will impose much more stringent requirements on both mode matching and mirror astigmatism

    Proton induced radioactivities

    Get PDF
    Results are tabulated of the radioactivities produced by 4 Mev protons in targets of 7N, 8O, 20Ca, 24Cr, 27Co, 30Zn, 34Se, 42Mo, 46Pd, 48Cd, 49In. In most cases the reactions are of the p-n type, and lead to isotopes which emit either + or - electrons. A detailed study was made of O, Zn and Se. The reaction O18(p, n)F18 (107 min.) shows a threshold at 2.56 Mev and a positron energy of 0.74 Mev in good agreement with the energy relations. The cross section for the reaction at 4 Mev is about 2×10^-25 cm^2 and there is a resonance maximum at 3.55 Mev. The cross section for the reaction O16(p, γ)F17 is 4000 times smaller. The isomeric Br80 periods (17.4 min. and 4.45 hr.) are observed in the reaction Se80(p, n)Br80. At 4 Mev the ratio of the short to long period activities for infinite bombardment is about 15 but the thresholds are at about 3.0 and 3.2 Mev, respectively. The cross section for the reaction is about 0.6×10^-26 cm^2 at 4 Mev

    Deep three-dimensional solid-state qubit arrays with long-lived spin coherence

    Get PDF
    Nitrogen-vacancy centers (NVCs) in diamond show promise for quantum computing, communication, and sensing. However, the best current method for entangling two NVCs requires that each one is in a separate cryostat, which is not scalable. We show that single NVCs can be laser written 6–15-µm deep inside of a diamond with spin coherence times that are an order of magnitude longer than previous laser-written NVCs and at least as long as naturally occurring NVCs. This depth is suitable for integration with solid immersion lenses or optical cavities and we present depth-dependent T2 measurements. 200 000 of these NVCs would fit into one diamond

    Huddle test measurement of a near Johnson noise limited geophone

    Get PDF
    In this paper, the sensor noise of two geophone configurations (L-22D and L-4C geophones from Sercel with custom built amplifiers) was measured by performing two huddle tests. It is shown that the accuracy of the results can be significantly improved by performing the huddle test in a seismically quiet environment and by using a large number of reference sensors to remove the seismic foreground signal from the data. Using these two techniques, the measured sensor noise of the two geophone configurations matched the calculated predictions remarkably well in the bandwidth of interest (0.01 Hz–100 Hz). Low noise operational amplifiers OPA188 were utilized to amplify the L-4C geophone to give a sensor that was characterized to be near Johnson noise limited in the bandwidth of interest with a noise value of 10−11 m/Hz⎯⎯⎯⎯⎯√10−11 m/Hz at 1 Hz
    • …