8,362 research outputs found

    Composite infrared bolometers with Si_3N_4 micromesh absorbers

    Get PDF
    We report the design and performance of 300-mK composite bolometers that use micromesh absorbers and support structures patterned from thin films of low-stress silicon nitride. The small geometrical filling factor of the micromesh absorber provides 20× reduction in heat capacity and cosmic ray cross section relative to a solid absorber with no loss in IR-absorption efficiency. The support structure is mechanically robust and has a thermal conductance, G < 2 × 10^(−11) W/K, which is four times smaller than previously achieved at 300 mK. The temperature rise of the bolometer is measured with a neutron transmutation doped germanium thermistor attached to the absorbing mesh. The dispersion in electrical and thermal parameters of a sample of 12 bolometers optimized for the Sunyaev–Zel’dovich Infrared Experiment is ±7% in R (T), ±5% in optical efficiency, and ±4% in G

    Corneal relaxation time estimation as a function of tear oxygen tension in human cornea during contact lens wear

    Full text link
    [EN] The purpose is to estimate the oxygen diffusion coefficient and the relaxation time of the cornea with respect to the oxygen tension at the cornea-tears interface. Both findings are discussed. From the experimental data provided by Bonanno et al., the oxygen tension measurements in vivo for human cornea-tears-contact lens (CL), the relaxation time of the cornea, and their oxygen diffusion coefficient were obtained by numerical calculation using the Monod-kinetic model. Our results, considering the relaxation time of the cornea, observe a different behavior. At the time less than 8 s, the oxygen diffusivity process is upper-diffusive, and for the relaxation time greater than 8 s, the oxygen diffusivity process is lower-diffusive. Both cases depend on the partial pressure of oxygen at the entrance of the cornea. The oxygen tension distribution in the cornea-tears interface is separated into two different zones: one for conventional hydrogels, which is located between 6 and 75 mmHg, with a relaxation time included between 8 and 19 s, and the other zone for silicone hydrogel CLs, which is located at high oxygen tension, between 95 and 140 mmHg, with a relaxation time in the interval of 1.5-8 s. It is found that in each zone, the diffusion coefficient varies linearly with the oxygen concentration, presenting a discontinuity in the transition of 8 s. This could be interpreted as an aerobic-to-anaerobic transition. We attribute this behavior to the coupling formalism between oxygen diffusion and biochemical reactions to produce adenosine triphosphate.Contract grant sponsor: Dirección General de Asuntos del Personal Académico, Universidad Nacional Autónoma de México; contract grant number: UNAM-DGAPA-PAPIIT projects IG 100618 and IN-114818 Contract grant sponsor: Secretaría de Estado de Investigación, Desarrollo e Innovación; contract grant number: ENE/2015-69203-RDel Castillo, LF.; Ramírez-Calderón, JG.; Del Castillo, RM.; Aguilella-Arzo, M.; Compañ Moreno, V. (2020). Corneal relaxation time estimation as a function of tear oxygen tension in human cornea during contact lens wear. Journal of Biomedical Materials Research Part B Applied Biomaterials. 108(1):14-21. https://doi.org/10.1002/jbm.b.34360S14211081Freeman, R. D. (1972). Oxygen consumption by the component layers of the cornea. The Journal of Physiology, 225(1), 15-32. doi:10.1113/jphysiol.1972.sp009927CHALMERS, R. L., McNALLY, J. J., SCHEIN, O. D., KATZ, J., TIELSCH, J. M., ALFONSO, E., … SHOVLIN, J. (2007). Risk Factors for Corneal Infiltrates with Continuous Wear of Contact Lenses. Optometry and Vision Science, 84(7), 573-579. doi:10.1097/opx.0b013e3180dc9a12Schein, O. D., McNally, J. J., Katz, J., Chalmers, R. L., Tielsch, J. M., Alfonso, E., … Shovlin, J. (2005). The Incidence of Microbial Keratitis among Wearers of a 30-Day Silicone Hydrogel Extended-Wear Contact Lens. Ophthalmology, 112(12), 2172-2179. doi:10.1016/j.ophtha.2005.09.014Sweeney, D. F. (2003). Clinical Signs of Hypoxia with High-Dk Soft Lens Extended Wear: Is the Cornea Convinced? Eye & Contact Lens: Science & Clinical Practice, S22-S25. doi:10.1097/00140068-200301001-00007HARVITT, D. M., & BONANNO, J. A. (1999). Re-Evaluation of the Oxygen Diffusion Model for Predicting Minimum Contact Lens Dk/t Values Needed to Avoid Corneal Anoxia. Optometry and Vision Science, 76(10), 712-719. doi:10.1097/00006324-199910000-00023Polse, K. A., & Mandell, R. B. (1970). Critical Oxygen Tension at the Corneal Surface. Archives of Ophthalmology, 84(4), 505-508. doi:10.1001/archopht.1970.00990040507021Giasson, C., & Bonanno, J. A. (1995). Acidification of rabbit corneal endothelium during contact lens wearin vitro. Current Eye Research, 14(4), 311-318. doi:10.3109/02713689509033531Riley, M. V. (1969). Glucose and oxygen utilization by the rabbit cornea. Experimental Eye Research, 8(2), 193-200. doi:10.1016/s0014-4835(69)80031-xFrahm, B., Lane, P., M�rkl, H., & P�rtner, R. (2003). Improvement of a mammalian cell culture process by adaptive, model-based dialysis fed-batch cultivation and suppression of apoptosis. Bioprocess and Biosystems Engineering, 26(1), 1-10. doi:10.1007/s00449-003-0335-zCompañ, V., Aguilella-Arzo, M., Del Castillo, L. F., Hernández, S. I., & Gonzalez-Meijome, J. M. (2016). Analysis of the application of the generalized monod kinetics model to describe the human corneal oxygen-consumption rate during soft contact lens wear. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105(8), 2269-2281. doi:10.1002/jbm.b.33764Bonanno, J. A., Clark, C., Pruitt, J., & Alvord, L. (2009). Tear Oxygen Under Hydrogel and Silicone Hydrogel Contact Lenses in Humans. Optometry and Vision Science, 86(8), E936-E942. doi:10.1097/opx.0b013e3181b2f582Chhabra, M., Prausnitz, J. M., & Radke, C. J. (2008). Diffusion and Monod kinetics to determine in vivo human corneal oxygen-consumption rate during soft contact-lens wear. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 90B(1), 202-209. doi:10.1002/jbm.b.31274Chhabra, M., Prausnitz, J. M., & Radke, C. J. (2009). Modeling Corneal Metabolism and Oxygen Transport During Contact Lens Wear. Optometry and Vision Science, 86(5), 454-466. doi:10.1097/opx.0b013e31819f9e70Larrea, X., & Bu¨chler, P. (2009). A Transient Diffusion Model of the Cornea for the Assessment of Oxygen Diffusivity and Consumption. Investigative Opthalmology & Visual Science, 50(3), 1076. doi:10.1167/iovs.08-2479Alvord, L. A., Hall, W. J., Keyes, L. D., Morgan, C. F., & Winterton, L. C. (2007). Corneal Oxygen Distribution With Contact Lens Wear. Cornea, 26(6), 654-664. doi:10.1097/ico.0b013e31804f5a22Del Castillo, L. F., da Silva, A. R. F., Hernández, S. I., Aguilella, M., Andrio, A., Mollá, S., & Compañ, V. (2015). Diffusion and Monod kinetics model to determine in vivo human corneal oxygen-consumption rate during soft contact lens wear. Journal of Optometry, 8(1), 12-18. doi:10.1016/j.optom.2014.06.002Chandel, N. S., Budinger, G. R. S., Choe, S. H., & Schumacker, P. T. (1997). Cellular Respiration during Hypoxia. Journal of Biological Chemistry, 272(30), 18808-18816. doi:10.1074/jbc.272.30.18808Leung, B. K., Bonanno, J. A., & Radke, C. J. (2011). Oxygen-deficient metabolism and corneal edema. Progress in Retinal and Eye Research, 30(6), 471-492. doi:10.1016/j.preteyeres.2011.07.001Chhabra, M., Prausnitz, J. M., & Radke, C. J. (2008). Polarographic Method for Measuring Oxygen Diffusivity and Solubility in Water-Saturated Polymer Films:  Application to Hypertransmissible Soft Contact Lenses. Industrial & Engineering Chemistry Research, 47(10), 3540-3550. doi:10.1021/ie071071aCompañ, V., Andrio, A., López-Alemany, A., Riande, E., & Refojo, M. F. (2002). Oxygen permeability of hydrogel contact lenses with organosilicon moieties. Biomaterials, 23(13), 2767-2772. doi:10.1016/s0142-9612(02)00012-1Gonzalez-Meijome, J. M., Compañ-Moreno, V., & Riande, E. (2008). Determination of Oxygen Permeability in Soft Contact Lenses Using a Polarographic Method:  Estimation of Relevant Physiological Parameters. Industrial & Engineering Chemistry Research, 47(10), 3619-3629. doi:10.1021/ie071403bCompa�, V., L�pez, M. L., Andrio, A., L�pez-Alemany, A., & Refojo, M. F. (1999). Determination of the oxygen transmissibility and permeability of hydrogel contact lenses. Journal of Applied Polymer Science, 72(3), 321-327. doi:10.1002/(sici)1097-4628(19990418)72:33.0.co;2-lGavara, R., & Compañ, V. (2016). Oxygen, water, and sodium chloride transport in soft contact lenses materials. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105(8), 2218-2231. doi:10.1002/jbm.b.33762Compañ, V., Tiemblo, P., García, F., García, J. M., Guzmán, J., & Riande, E. (2005). A potentiostatic study of oxygen transport through poly(2-ethoxyethyl methacrylate-co-2,3-dihydroxypropylmethacrylate) hydrogel membranes. Biomaterials, 26(18), 3783-3791. doi:10.1016/j.biomaterials.2004.09.061Wang, J., Fonn, D., Simpson, T. L., & Jones, L. (2003). Precorneal and Pre- and Postlens Tear Film Thickness Measured Indirectly with Optical Coherence Tomography. Investigative Opthalmology & Visual Science, 44(6), 2524. doi:10.1167/iovs.02-0731Nichols, J. J., & King-Smith, P. E. (2003). Thickness of the Pre- and Post–Contact Lens Tear Film Measured In Vivo by Interferometry. Investigative Opthalmology & Visual Science, 44(1), 68. doi:10.1167/iovs.02-0377Compañ, V., Aguilella-Arzo, M., Edrington, T. B., & Weissman, B. A. (2016). Modeling Corneal Oxygen with Scleral Gas Permeable Lens Wear. Optometry and Vision Science, 93(11), 1339-1348. doi:10.1097/opx.0000000000000988Compañ, V., Aguilella-Arzo, M., & Weissman, B. A. (2017). Corneal Equilibrium Flux as a Function of Corneal Surface Oxygen Tension. Optometry and Vision Science, 94(6), 672-679. doi:10.1097/opx.0000000000001083Papas, E. B., & Sweeney, D. F. (2016). Interpreting the corneal response to oxygen: Is there a basis for re-evaluating data from gas-goggle studies? Experimental Eye Research, 151, 222-226. doi:10.1016/j.exer.2016.08.019Alentiev, A. Y., Shantarovich, V. P., Merkel, T. C., Bondar, V. I., Freeman, B. D., & Yampolskii, Y. P. (2002). Gas and Vapor Sorption, Permeation, and Diffusion in Glassy Amorphous Teflon AF1600. Macromolecules, 35(25), 9513-9522. doi:10.1021/ma020494fLin, H., & Freeman, B. D. (2005). Gas and Vapor Solubility in Cross-Linked Poly(ethylene Glycol Diacrylate). Macromolecules, 38(20), 8394-8407. doi:10.1021/ma051218eKoros, W. J., Paul, D. R., & Rocha, A. A. (1976). Carbon dioxide sorption and transport in polycarbonate. Journal of Polymer Science: Polymer Physics Edition, 14(4), 687-702. doi:10.1002/pol.1976.180140410Nicolson, P. C., & Vogt, J. (2001). Soft contact lens polymers: an evolution. Biomaterials, 22(24), 3273-3283. doi:10.1016/s0142-9612(01)00165-xCheng, X., & Pinsky, P. M. (2017). A numerical model for metabolism, metabolite transport and edema in the human cornea. Computer Methods in Applied Mechanics and Engineering, 314, 323-344. doi:10.1016/j.cma.2016.09.014Li, L., & Tighe, B. (2005). Numerical simulation of corneal transport processes. Journal of The Royal Society Interface, 3(7), 303-310. doi:10.1098/rsif.2005.008

    ARM-Cortex M3-Based Two-Wheel Robot for Assessing Grid Cell Model of Medial Entorhinal Cortex: Progress towards Building Robots with Biologically Inspired Navigation-Cognitive Maps

    Get PDF
    This article presents the implementation and use of a two-wheel autonomous robot and its effectiveness as a tool for studying the recently discovered use of grid cells as part of mammalian’s brains space-mapping circuitry (specifically the medial entorhinal cortex). A proposed discrete-time algorithm that emulates the medial entorhinal cortex is programed into the robot. The robot freely explores a limited laboratory area in the manner of a rat or mouse and reports information to a PC, thus enabling research without the use of live individuals. Position coordinate neural maps are achieved as mathematically predicted although for a reduced number of implemented neurons (i.e., 200 neurons). However, this type of computational embedded system (robot’s microcontroller) is found to be insufficient for simulating huge numbers of neurons in real time (as in the medial entorhinal cortex). It is considered that the results of this work provide an insight into achieving an enhanced embedded systems design for emulating and understanding mathematical neural network models to be used as biologically inspired navigation system for robots

    Dimensionalities of Weak Solutions in Hydrogenic Systems

    Full text link
    A close inspection on the 3D hydrogen atom Hamiltonian revealed formal eigenvectors often discarded in the literature. Although not in its domain, such eigenvectors belong to the Hilbert space, and so their time evolution is well defined. They are then related to the 1D and 2D hydrogen atoms and it is numerically found that they have continuous components, so that ionization can take place

    Fístula arteriovenosa postraumática: tratamiento endovascular. Revisión de la literatura y presentación de un caso clínico

    Get PDF
    ResumenLas fístulas arteriovenosas en la cabeza y el cuello son entidades poco frecuentes. La mayoría es secundaria a heridas penetrantes por arma blanca. Se describe el tratamiento exitoso mediante cirugía endovascular de una fístula postraumática tras una herida penetrante entre la arteria maxilar interna izquierda y la vena yugular externa. A través de este caso clínico y la revisión de la literatura se ilustran las causas, manifestaciones, estudio radiológico y tratamiento de una fístula postraumática entre la arteria maxilar interna y la vena yugular externa. A través de este caso clínico se demuestra la utilidad de los procedimientos endovasculares en el tratamiento de estas complicaciones.AbstractTraumatic arteriovenous fistulas of the head and neck region are uncommon. The majority are due to penetration of blunt injury. We describe a successful endovascular treatment of a posttraumatic fistula between the left maxillary artery and the external jugular vein due to a penetration injury. This case and a review of the literature illustrate the causes, manifestations, image studies and treatment for a posttraumatic fistula between the maxillary artery and the external jugular vein. This case demonstrate the utility of endovascular treatment of head and neck injuries complications

    Evaluating Molecular Cobalt Complexes for the Conversion of N_2 to NH_3

    Get PDF
    We report a molecular Co−N_2 complex that generates a greater-than-stoichiometric yield of NH_3 (>200% NH_3 per Co−N_2 precursor) via the direct reduction of N_2 with protons and electrons. A comparison of the featured Co−N_2 complex with structurally related Co−N_2 and Fe−N_2 species shows how remarkably sensitive the N_2 reduction performance of potential precatalysts is. As discussed, structural and electronic effects are relevant to Co/Fe−N_2 conversion activity, including π basicity, charge state, and geometric flexibility

    Geometrothermodynamics

    Get PDF
    We present the fundamentals of geometrothermodynamics, an approach to study the properties of thermodynamic systems in terms of differential geometric concepts. It is based, on the one hand, upon the well-known contact structure of the thermodynamic phase space and, on the other hand, on the metric structure of the space of thermodynamic equilibrium states. In order to make these two structures compatible we introduce a Legendre invariant set of metrics in the phase space, and demand that their pullback generates metrics on the space of equilibrium states. We show that Weinhold's metric, which was introduced {\it ad hoc}, is not contained within this invariant set. We propose alternative metrics which allow us to redefine the concept of thermodynamic length in an invariant manner and to study phase transitions in terms of curvature singularities.Comment: Revised version, to be published in Jour. Math. Phy
    corecore