307,911 research outputs found

    External losses in photoemission from strongly correlated quasi two-dimensional solids

    Full text link
    New expressions are derived for photoemission, which allow experimental electron energy loss data to be used for estimating losses in photoemission. The derivation builds on new results for dielectric response and mean free paths of strongly correlated systems of two dimensional layers. Numerical evaluations are made for Bi2Sr2CaCu2O8Bi_{2}Sr_{2}CaCu_{2}O_{8} (Bi2212) by using a parametrized loss function. The mean free path for Bi2212 is calculated and found to be substantially larger than obtained by Norman et al in a recent paper. The photocurrent is expressed as the convolution of the intrinsic approximation for the current from a specific 2D layer with an effective loss function. The observed current is the sum of such currents from the first few layers. The photo electron from a specific CuOCuO layer is found to excite low energy acoustic plasmon modes due to the coupling between the CuOCuO layers. These modes give rise to an asymmetric power law broadening of the photo current an isolated two dimensional layer would have given. We define an asymmetry index where a contribution from a Luttinger lineshape is additive to the contribution from our broadening function. Already the loss effect considered here gives broadening comparable to what is observed experimentally. A superconductor with a gapped loss function is predicted to have a peak-dip-hump lineshape similar to what has been observed, and with the same qualitative behavior as predicted in the recent work by Campuzano et al.Comment: 17 pages, 10 figure

    Quantitative absorption and fluorescence studies of NO between 1060 and 2000 A

    Get PDF
    Synchrotron radiation in the 1060 to 2000 A region was used to measure the average absorption and fluorescence cross sections of NO and to determine approximate photodissociation quantum yields. Several vibrational levels of the D(2) sigma(+), E(2) sigma(+), and B(2) delta states have high fluorescence quantum yields. The C(2) and B(2) states do not fluoresce when the excitation energies are above the first dissociation limit, in accord with previous experiments. In general, the fluorescence yields decrease with increasing photon energy. The quantitative measurements are compared with spectroscopic observations and are found to be reasonably consistent

    Interference cancellation assisted lattice-reduction aided detection for MIMO systems

    No full text
    In this paper, we proposed and investigated the optimal successive interference cancellation (SIC) strategy designed for lattice-reduction-aided multiple-input multiple-output (MIMO) detectors. For the sake of generating the optimal MIMO symbol estimate at each SIC detection stage, we model the so-called effective symbols generated with the aid of lattice-reduction as joint Gaussian distributed random variables. However, after lattice-reduction, the effective symbols become correlated and exhibit a non-zero mean. Hence, we derive the optimal minimum-mean-squared-error (MMSE) SIC detector, which updates the mean and variance of the effective symbols at each SIC detection stage. As a result, the proposed detector achieves an approximately 3 dB Eb/N0 gain and performs close to the maximum likelihood detector

    Optimal Lattice-Reduction Aided Successive Interference Cancellation for MIMO Systems

    No full text
    In this letter, we investigated the optimal minimummean-squared-error (MMSE) based successive interference cancellation (SIC) strategy designed for lattice-reduction aided multiple-input multiple-output (MIMO) detectors. For the sake of generating the MMSE-based MIMO symbol estimate at each SIC detection stage, we model the so-called effective symbols generated with the aid of lattice-reduction as joint Gaussian distributed random variables. However, after lattice-reduction, the effective symbols become correlated and exhibit a non-zero mean. Hence, we derive the optimal MMSE SIC detector, which updates the mean and variance of the effective symbols at each SIC detection stage. As a result, the proposed detector achieves a better performance compared to its counterpart dispensing with updating the mean and variance, and performs close to the maximum likelihood detector. Index Terms—Lattice-reduction, multiple antennas, MIMO, symbol detection, SIC detector
    corecore